Description
Backup battery for your GE Datex Aestiva 7100
Ensure the continuous operation of your GE Datex Aestiva 7100 ventilator and anaesthesia system with this internal rechargeable sealed lead-acid battery of 6 V and 4 Ah. It is the indicated spare part to maintain ventilation and anaesthesia monitoring during intra-hospital transfers, emergencies or power supply cuts. A reliable, leak-proof and maintenance-free solution, designed for institutional purchase and for the preventive maintenance of the fleet of respiratory and ventilation equipment.
What this battery is and how it works
The GE Datex Aestiva 7100 is an anaesthesia system with an integrated ventilator that incorporates an internal sealed lead-acid battery (SLA/VRLA) as a backup power source. While the equipment is connected to the mains, the battery remains on float charge; when it is disconnected to move the patient or in the event of a mains failure, it automatically takes over the power supply without interrupting ventilation. VRLA/AGM technology is completely leak-proof and requires no maintenance: it does not spill electrolyte and can be installed in any position within the equipment compartment. After replacing the cell, it is advisable to let the equipment complete its power-on self-test and perform a full charge and discharge cycle so that the electronics recalibrate the low-battery thresholds.
Technical specifications
| Parameter | Value |
|---|---|
| Application | Ventilator / anaesthesia system GE Datex Aestiva 7100 (GE Healthcare) |
| Technology | Sealed lead-acid (SLA / VRLA), maintenance-free |
| Nominal voltage | 6 V |
| Nominal capacity | 4 Ah (24 Wh) |
| Rechargeable | Yes; float charge managed by the equipment |
| Approximate weight | 0.66 kg |
| Dimensions | 70 × 47 × 102 mm |
| Catalogue reference Cahnos | 88888456 |
| Equipment manufacturer | GE Healthcare |
| Reference data | Value |
|---|---|
| GE OEM part (battery assembly, exact replacement) | M1081511-S |
| GE OEM part that replaces (previous phase) | 1504-3505-000 |
| Reference indicated on the original data sheet | 1504-3005-000 (see note in equivalences) |
| Spare part type | Sealed lead-acid cell, premium compatible quality |
Equivalences and cross-references
Verification note for reference 1504-3005-000: after cross-checking with public sources, this code could not be verified as a battery for the Aestiva 7100. In official parts catalogues (PartsSource, CNA Medical) reference 1504-3005-000 appears documented as the PEEP port / inspection and calibration tool for the 7100 ventilator, i.e. a different product. The battery for this equipment is documented as GE OEM assembly M1081511-S (sealed lead battery 6 V 4 Ah, according to the official GE Healthcare parts store), which replaces the 1504-3505-000 phase. It is recommended to confirm the reference stamped on the installed battery before placing the order.
Reference 88888456 is the catalogue’s own coding from Cahnos for this generic spare part. The cell corresponds to the standard sealed lead-acid format of 6 V and 4 Ah (approximate case 70 × 47 × 102–105.5 mm), a family documented in the official technical data sheets of the cell manufacturers indicated below; the cross-references share chemistry, voltage and capacity, but the height dimension and connector must be verified before assembly.
| Cell manufacturer | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| GS Yuasa | NP series (standby and cyclic) | NP4-6 | Comparable by category (not interchangeable 1:1) | 6 V 4 Ah (20 h rate), 70 × 47 × 105.5 mm, 0.87 kg, Faston 187 terminal (≈F1). Verified in official GS Yuasa datasheet. Difference: height 105.5 mm versus 102 mm; check compartment housing. |
| Power-Sonic | PS series (general use) | PS-640 | Comparable by category (not interchangeable 1:1) | 6 V 4.5 Ah (20 h rate), F1 terminal (0.187″), format 70 × 47 × 105.5 mm. Verified in official Power-Sonic datasheet. Higher capacity and height; verify charging electronics and fit before replacing. |
As support, the cross-reference tables published by medical battery distributors also cite for the Aestiva 7100 the codes of repackagers (OM11877, B11877, 6425, EE400216); these references come from third parties and must be confirmed with the cell manufacturer before use. There is no equivalence table validated by the manufacturer (GE Healthcare) for this cell; consult the technical department before using in a tender.
Selection tips and variants of interest
- Identify the equipment: this battery corresponds to the GE Datex Aestiva 7100 anaesthesia system with ventilator. Confirm the exact model and the label of the installed battery (6 V, sealed lead) before replacing.
- Do not confuse it with other chemistries or voltages: the Aestiva 7000 uses a 12 V 2.3 Ah battery (Ref. Cahnos 88888128) and the Datex Ohmeda Excel 7800 a 4.8 V Ni-Cd one (Ref. Cahnos 88888472). Always verify the voltage indicated on the equipment.
- Check the connector and housing: review the terminal type (Faston F1 or other) and the compartment dimensions with the battery to be replaced before installing an equivalent cell.
- After replacement: charge the battery before first use and let the equipment complete its power-on self-test; a full charge and discharge cycle helps recalibrate the low-battery threshold.
- Storage: avoid prolonged deep discharges and keep the battery in a cool, dry place; if stored, recharge it periodically to avoid falling below the equipment’s recovery threshold.
- Recycling: lead batteries must be recycled at authorised points in accordance with current WEEE regulations.
- Should you have any questions, contact our technical department stating the model, serial number and reference of the fitted battery; we will confirm compatibility before the order is placed.