Description
1. Commercial Introduction
At Cahnos we offer you the replacement internal battery 12 V / 3.4 Ah sealed lead-acid (SLA) for the Dräger Evita 4 ventilator (Ref. 88888158). This is a highly reliable spare part designed to keep your ventilator operational when mains power is unavailable: intra-hospital transfers, operating theatre preparation, low battery warnings during ventilation, or power cuts. It is the ideal solution for intensive care services, critical care units, anaesthesia and medical electronics maintenance programmes, offering a very competitive price-performance ratio compared with the original part without compromising the electrical performance required by the equipment.
2. Technical explanation of the equipment
The Dräger Evita 4 ventilator is a high-end critical care ventilator that incorporates a backup internal power supply module. When the device is disconnected from the mains or the patient is moved, that module relies on its internal sealed lead-acid (SLA/VRLA) accumulators to maintain the control electronics, monitoring, ventilation and alarms. According to the manufacturer’s spare parts technical documentation, the Evita 4 uses two internal 12 V cells per unit (Dräger kit 8421988).
The SLA/VRLA (valve-regulated) chemistry is the one indicated for this application: it is rechargeable, fully sealed, maintenance-free, resistant to vibration and suitable for operation in various positions, characteristics required by equipment that operates continuously in a hospital environment. The battery recharges automatically while the ventilator remains connected to the mains. When the autonomy decreases appreciably or the equipment warns of low battery, it is time to replace the cells to ensure continuity and safety of ventilation.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Application | Dräger Evita 4 ventilator (internal power supply module); also documented for Evita 2 dura and Evita XL in the spare parts market |
| Original manufacturer reference | 8421988 (kit of 2 internal batteries) / 1887955 (individual battery) |
| Technology | Sealed lead-acid (SLA / VRLA), rechargeable, maintenance-free |
| Nominal voltage | 12 V |
| Nominal capacity | 3.4 Ah |
| Theoretical energy | 40.8 Wh (12 V × 3.4 Ah) |
| Number of cells per unit | 2 units (documented in the Dräger 8421988 kit; confirm your equipment configuration) |
| Weight | Approximately 1.2 kg |
| Dimensions (standard cell) | Approx. 134 × 67 × 60 mm (indicative; verify with the installed part) |
| Rechargeable | Yes; automatic recharging when the equipment is connected to the mains |
| Device manufacturer | Dräger |
| SKU Cahnos | 88888158 |
4. Equivalences and Cross-References
Important verification note: in the original datasheet this product was listed with the original reference 1843303. That numbering corresponds, in Dräger’s official spare parts list, to the external trolley battery of the Evita 2, 12 V and 17 Ah (at Cahnos, Ref. 88888157), not to the internal 3.4 Ah battery of the Evita 4. The internal battery of the Evita 4 is identified in the spare parts technical documentation as Dräger 8421988 (kit of 2 cells) / 1887955 (individual cell). Always confirm the numbering stamped on the installed battery before replacing.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Dräger (device manufacturer) | Kit of 2 internal batteries Evita 2 dura / Evita 4 / Evita XL | 8421988 | Exact reference equivalence (same manufacturer) | Official kit of 2 VRLA cells 12 V (3.2–3.5 Ah depending on version) for the internal power supply module; verified in spare parts documentation and technical distribution. |
| Dräger (device manufacturer) | Individual Evita internal battery (cell) | 1887955 | Exact reference equivalence (same manufacturer) | Individual cell from kit 8421988; documented as VRLA 12 V / 3.2 Ah (Vision CP1232 F1). |
| Genesis (Unipower / OSI Batteries) | NP series (standard SLA cell) | NP3.4-12 | Comparable by category (not interchangeable 1:1) | Standard SLA cell 12 V / 3.4 Ah, same chemistry and voltage; verify terminals (F1/F2), connector and terminal orientation. |
| Power-Sonic | PS series (VRLA cell) | PS-1230 / PS-1230-7 | Comparable by category (not interchangeable 1:1) | SLA cell 12 V / 3.4 Ah; referenced by distributors for Evita, Savina XL, 2 and 4 (2 units per device); verify housing and connector. |
| Vision Battery | CP series (VRLA cell) | CP1232 | Comparable by category (not interchangeable 1:1) | VRLA cell 12 V / 3.2 Ah; same model documented within the individual kit 1887955. Capacity slightly lower than 3.4 Ah; verify compartment. |
There is no equivalence table validated by the manufacturer (Dräger) that cross-references this part number with third-party brands; the alternatives indicated have been verified against specialised technical distribution catalogues and cell manufacturers’ product datasheets, and they share chemistry (SLA/VRLA) and voltage (12 V) with our spare part, but the 1:1 replacement must be validated field by field: voltage, capacity, dimensions, terminals (F1/F2), connector and terminal orientation. In the spare parts market there are also other compatible cell codes for the same application (e.g. R&D Batteries 5972-1); treat them as indicative pending confirmation. For use in tenders, consult the technical department of Cahnos before replacing.
5. Selection tips and variants of interest
- Identify the exact device and the number of cells: the internal power supply module of the Evita 4 is documented with 2 batteries of 12 V per device (kit 8421988). Check how many cells your unit has and always replace the complete set to maintain balanced autonomy.
- Do not confuse the internal battery with the trolley battery: reference 1843303 (12 V / 17 Ah) is the external trolley battery of the Evita 2 (at Cahnos, Ref. 88888157) and is not interchangeable with this internal 3.4 Ah battery.
- Verify the label of the installed battery: confirm voltage (12 V), chemistry (SLA/VRLA) and numbering (8421988, 1887955 or other) before replacing. Do not use cells of a different voltage or chemistry without validation from the technical service.
- After replacement: leave the ventilator connected to the mains to complete the charge and perform an autonomy test before returning the device to clinical service.
- Storage: keep the cells in a dry place, at room temperature and with periodic charges if the device remains unused, to extend their service life.
- Variants of the same family at Cahnos: external battery 12 V / 17 Ah for Evita 2 trolley (Ref. 88888157), Ni-Cd battery 7.2 V / 1 Ah for Oxylog 2000 (Ref. 88888150) and battery 12 V / 2.3 Ah for GE Datex Aestiva 7000 (Ref. 88888128). Do not interchange these references between models.
- Institutional orders: for tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formalised quotation.