Description
1. Reliable power for your Dräger Babylog VN5000 ventilator
At Cahnos we offer you the replacement battery for the neonatal and infant ventilator Dräger Babylog VN5000 (Ref. Cahnos 88881016), corresponding to the original manufacturer reference 8415290-08. This nickel-metal hydride (Ni-MH) accumulator of 24 V and 2.5 Ah restores the full autonomy of the equipment so that assisted ventilation does not suffer interruptions during intrahospital transfers, patient mobilisation or power supply cuts. It is the spare part that returns your ventilator to full operability with an excellent value for money, without giving up the reliability required for life support. Ideal solution for neonatology services, neonatal intensive care units (NICU), medical transport and medical electronics departments.
2. How this battery works in your equipment
The Dräger Babylog VN5000 is an intensive care ventilator designed for invasive and non-invasive ventilation of newborns and infants, common in NICU and neonatal transport. When the equipment is disconnected from the mains, its internal power supply module depends on the accumulator to sustain the control electronics, ventilation, monitoring and safety alarms without interruption.
This pack uses nickel-metal hydride (Ni-MH) chemistry, which offers stable current delivery, good energy density and robust behaviour against memory effect compared with classic nickel-cadmium chemistries. The accumulator is rechargeable: while the ventilator remains connected to the mains, the equipment itself keeps the battery charged automatically. When autonomy is noticeably reduced or the ventilator warns of low battery prematurely, it is time to replace the pack with this reference. Replacement is carried out in the original compartment of the equipment, without the need to modify the device.
3. Technical Specifications
Technical data collected from the product data sheet and cross-checked with specialised technical distribution sources:
| Parameter | Specification |
| Application | Dräger Babylog VN5000 ventilator (neonatal and infant ventilation); documented in specialised distribution for Evita Infinity V500, Evita V300/V600 and VN600/VN800 |
| Original manufacturer reference | 8415290-08 |
| Technology | Nickel-Metal Hydride (Ni-MH), rechargeable |
| Nominal voltage | 24 V |
| Nominal capacity | 2.5 Ah (2500 mAh) |
| Theoretical energy | 60 Wh (24 V × 2.5 Ah) |
| Weight | Approximately 1.24 kg |
| Dimensions | 200 × 120 × 27 mm |
| Rechargeable | Yes; automatic recharging when the equipment is connected to the mains |
| Installation | Direct replacement in the battery compartment, no modifications required |
| Device manufacturer | Dräger |
| SKU Cahnos | 88881016 |
Always check the label of the battery installed in your equipment before placing the order.
4. Equivalences and Cross-References
Reference 8415290-08 is consistently documented in the spare parts market as the original 24 V / 2.5 Ah battery for the Dräger Babylog VN500 / VN5000 ventilator, a shared platform according to specialised distribution with the Evita Infinity V500 and Evita V300 families. There is no equivalence table validated by Dräger itself that authorises third-party batteries for this reference; the alternatives listed below come from independent biomedical spare parts manufacturers and distributors and have been cross-checked against their product data sheets. Before replacing, always confirm chemistry, voltage, capacity, connector and dimensions against the removed part.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Dräger (device manufacturer) | Internal battery for Babylog VN500 / VN5000 ventilator | 8415290-08 | Exact reference equivalence (same manufacturer) | Original Ni-MH 24 V / 2.5 Ah battery; it is the reference that our spare part replaces. Confirm the variant engraved on the installed battery. |
| OSI Batteries (biomedical spare part) | Draeger Babylog VN500 Ventilator Battery | B11725 | Comparable by category (not interchangeable 1:1) | Ni-MH 24 V / 2.5 Ah; replacement that substitutes the original part 8415290-08 (public OSI Batteries data sheet). Verify connector and housing before replacing. |
| Kingsener (replacement) | Battery pack VN500 / Evita V500 / V300 | 8415290-13 (replaces 8415290-08 / -11) | Comparable by category (not interchangeable 1:1) | 24 V / 2500 mAh pack in Li-ion chemistry (not Ni-MH); documented for Evita V500, Evita V300 and Babylog VN500. Confirm connector and charging protocol of the equipment before replacing. |
Furthermore, in the spare parts market the variants 8415290-11 and 8415290-13 frequently appear associated with this same accumulator; they have not been verified against the manufacturer’s official data sheet, so they should be treated as references documented in distribution pending confirmation with the supplier before use. There is no equivalence table validated by the manufacturer (Dräger) that cross-references this reference with third-party brands; consult the technical department of Cahnos before using in tenders.
5. Selection tips and variants of interest
- Identify the exact reference of your battery: confirm the number engraved on the installed battery (8415290-08 or another variant) before requesting the replacement. This battery corresponds to the Dräger Babylog VN5000 ventilator; do not confuse it with the Babylog Carina battery (12 V), which is not interchangeable.
- Check voltage, chemistry and connector: the Babylog VN5000 uses a 24 V Ni-MH pack with a specific connector. Do not replace with batteries of other voltage or chemistry even if the housing looks similar, unless validated by the technical service.
- Ni-MH maintenance: avoid repeated deep discharges and keep the accumulator charged if the equipment is to remain unused for several days, to extend its service life. Performance depends on the cycle history and ambient temperature.
- After installation: leave the ventilator connected to the mains to complete the charge and carry out a battery autonomy test before returning the equipment to clinical service.
- Recycling: dispose of the exhausted battery at an authorised collection point in accordance with WEEE regulations.
- Institutional orders: for tenders, ongoing supply contracts or procurement bids, contact the technical-commercial department at Cahnos to validate exact compatibility with your equipment fleet and obtain a formalised quotation under B2B terms.





Reviews