Description
1. Reliable, sustainable power for your patient lift
Keep your Sygma Duo-Box patient lifting system (MFR Liftmaster family) operational with this reconditioning service for the 24V 5Ah battery, reference Cahnos 88888808. Instead of purchasing a complete pack, send your depleted battery and our workshop will renew it with quality sealed lead-acid cells (Exalium assembly), returning a unit ready for use with warranty. It is the ideal solution for medical electronics services, transfer hoist fleet maintenance and purchasing departments seeking to reduce cost and environmental footprint without compromising the electrical performance required by the equipment.
2. How this battery works in the patient lift
The Sygma Duo-Box patient lift is a mobile transfer hoist that uses a sealed lead-acid rechargeable battery pack to power the control electronics and the lifting actuator when the equipment is not connected to the mains: transfers between rooms, bed-to-chair manoeuvres, assisted baths and situations of power supply failure. The reconditioned pack exactly reproduces the electrical configuration of the original: two 12V 5Ah cells connected in series (NPH5-12 format) inside the double case of the Duo-Box, so replacement is carried out without modifying the charger, wiring or connectors.
A degraded battery manifests itself in slow manoeuvres, low battery warnings or stops at mid-height, risk situations during patient mobilisation. The reconditioning service restores the nominal capacity (120Wh) and the stability of current delivery, guaranteeing continuity of care in hospitals, care homes and social healthcare centres.
3. Technical Specifications
| Parameter | Specification |
| Application | Sygma Duo-Box patient lifting systems, MFR Liftmaster family (patient transfer hoists) |
| Service | Reconditioning of the used battery with warranty (return of spent unit) |
| Original pack reference | SY325DBA (Sygma Duo-Box) |
| Reference Cahnos | 88888808 (SKU 0159022) |
| Technology | Sealed lead-acid (SLA/AGM), rechargeable; double-case pack with 2 12V cells in series |
| Cell format | NPH5-12 (2 × 12V 5Ah) |
| Nominal voltage | 24V |
| Capacity | 5Ah |
| Energy | 120Wh |
| Weight | Approximately 1.8 kg (according to datasheet; specialist distribution cites 2.832 kg with Duo-Box casings) |
| Dimensions | 150 x 95 x 60 mm (pack according to datasheet; check housing against the removed unit) |
| Recharge | Yes; with the lift charger (connected to mains) |
| Device manufacturer | Sygma (Duo-Box / Liftmaster lift) |
Verification note: the voltage, capacity and energy values correspond to the reconditioned pack that reproduces the original reference SY325DBA documented in the specialised distribution catalogue for the Duo-Box lift. Before the service, compare the reference stamped on the label of the removed battery.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer (Sygma) that cross-references the SY325DBA reference of the Duo-Box pack with third-party spare parts for this lift. The alternatives indicated below have been checked against battery manufacturer datasheets and specialised technical distribution; they share a 24V voltage and capacity window (5–5.5Ah), but physical replacement must be validated field by field (connector, polarity, housings and compartment) before any assembly.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Axcom | Cell replacement order for Sygma DUO-BOX Lifter (lead-acid) | MBU0110 | Comparable by category (not interchangeable 1:1) | Equivalent cell replacement service on the DUO-BOX battery (OEM SY325DBA) rated at 24V 5.4Ah; carried out on the housing sent, check shipping policy and capacities. |
| BestCare | Battery for electric patient lift (pack of 2) | BA-24-V2 | Comparable by category (not interchangeable 1:1) | 24V 5Ah SLA pack intended for BestCare lifts; same electrical specification but housings and connector specific to the equipment manufacturer, not compatible with the Duo-Box without verification. |
| Alco Sales | 24V 5.5Ah battery pack for patient lift | AL-26396 | Comparable by category (not interchangeable 1:1) | Generic lead pack for patient lifts with slightly higher capacity (5.5Ah); check voltage, connector and compartment against the removed pack. |
| Sygma (higher variant of the same lift) | 24V 10Ah battery for Duo-Box (Li-ion, compatible) | Distribution reference 88890737 | Comparable by category (not interchangeable 1:1) | Higher capacity variant for the same Duo-Box lift but with lithium-ion chemistry; only installable if the charger and the equipment electronics allow it. |
There is no equivalence table validated by the manufacturer that authorises third-party batteries for reference SY325DBA; consult the technical department before using this reference in a tender or before replacing the original pack with a spare part from another manufacturer. At cell level, the standard NPH5-12 (12V 5Ah) sealed lead-acid pack is the documented basis of the 24V assembly, but reconditioning must reproduce the exact configuration and connectors of the Duo-Box.
5. Selection tips and variants of interest
How the service works: contact our technical department, send your depleted Sygma Duo-Box battery (reference SY325DBA, 24V 5Ah) and our workshop will replace the cells, check housings, contacts and fuses, and deliver the reconditioned unit with warranty. Always state the lift model and the reference stamped on the label.
Check before sending: confirm that the removed battery corresponds to the 24V 5Ah Duo-Box pack (SY325DBA). Do not send packs of another voltage or from other manufacturer families (e.g. Ni-MH) for this lead service.
Pack maintenance: if the lift remains unused, recharge the battery periodically (approximately every 6 to 8 weeks) to avoid deep discharges that shorten service life. After return of the reconditioned pack, charge it fully and carry out a no-load lifting test before putting it back into clinical service.
Do not alter voltage or chemistry: always use 24V sealed lead-acid packs with the lift’s original charger. Higher capacity variants or other chemistries (e.g. Li-ion 24V 10Ah) should only be considered if the Duo-Box charger and electronics allow it.
Environmental management: at the end of its service life, take the used battery to a recycling point or authorised WEEE/battery management operator; do not dispose of it in the general waste container. For institutional orders, tenders or continuous supply contracts for reconditioned packs, our technical-commercial team will confirm exact compatibility with your lift and offer special volume conditions.