Description
1. Reliable power for your Arjo Minstrel lift
Keep your patient lifting system Arjo Minstrel operational with this compatible battery that replaces the original reference TGT223. With 24 V and 5.5 Ah capacity, it restores the equipment’s autonomy needed for patient lifting and transfer manoeuvres in hospitals, care homes and social health centres, without depending on the mains power supply.
It is the practical solution for maintenance services, biomedical engineering and purchasing departments that need traceable spare parts of proven quality to keep their fleet of Arjo equipment operational, at a significantly lower cost than the original replacement.
2. Technical explanation of the component
The Arjo patient lift powers its lifting motor via an internal rechargeable battery when the equipment is not connected to the mains. When the autonomy is noticeably reduced, the equipment warns of low battery prematurely or the lifting becomes slow, it is time to replace the battery with this reference of 24 V / 5.5 Ah (132 Wh).
As it is a compatible direct replacement part, it is installed in the battery compartment respecting the orientation and connector of the equipment, and is recharged with the lift’s own charger. The robust housing and protection against short circuits and overheating guarantee safe operation in healthcare environments.
Technical note: the commercial data sheet describes this battery as Ni-MH of approximately 1.8 kg; however, the technical documentation from biomedical spare parts manufacturers and specialised distributors identifies the pack that replaces reference TGT.223 as sealed lead-acid (SLA/VRLA AGM) of 24 V / 5.5 Ah with a weight close to 4.4 kg. Before replacing, check the label of the installed battery and the chemistry for which your equipment’s charger is set.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Application | Arjo Minstrel patient lifting system (reference TGT223; also cited for Arjo/Medibo Excelsior, Gemini and Minerva verticalisers according to authorised distribution) |
| Reference Cahnos (SKU) | 88889873 |
| Compatible reference | TGT223 |
| Technology | Ni-MH (Nickel-Metal Hydride) according to commercial data sheet; spare parts technical documentation identifies the TGT223 pack as SLA/VRLA AGM (check label) |
| Nominal voltage | 24 V |
| Capacity | 5.5 Ah |
| Energy | 132 Wh |
| Weight | Approximately 1.8 kg (commercial data sheet); ≈ 4.4 kg according to SLA/VRLA spare parts technical documentation |
| Dimensions | 150 x 95 x 70 mm (commercial data sheet) |
| Device manufacturer | Arjo |
| Type | Rechargeable compatible battery for patient lifts |
| Rechargeable | Yes; recharge with the lift charger |
| Installation | Direct replacement in the lift compartment, without tools |
| Presentation | 1 unit |
| Recycling | Manage in accordance with WEEE regulations |
4. Equivalences and Cross-References
The Arjo TGT223 reference (24 V / 5.5 Ah) has been cross-checked against biomedical battery manufacturers and specialised distribution catalogues. Arjo does not publish an official equivalence table authorising third-party batteries; the following references share the electrical platform and are classified as comparable by category, not interchangeable 1:1, and must be validated field by field (voltage, chemistry, dimensions and connector) with the specific equipment before replacement.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| MSP Medical | Battery Pack 24V/DC 5.5Ah for Arjo/Medibo patient lifts (replaces TGT.223) | MSP-A-MB-00100 (EAN 8719925310218) | Comparable by category (not interchangeable 1:1) | SLA/VRLA AGM 24 V / 5.4 Ah; designed for Arjo/Medibo Excelsior, Gemini and Minerva lifts; MDR compliant; same electrical platform as this data sheet; slightly lower capacity (5.4 vs 5.5 Ah) and different chemistry to that described; check connector and dimensions. Confirmed in the spare part manufacturer’s data sheet. |
| ALCO / Direct Supply | Battery Pack 24V 5.5Ah for Arjo patient lifts | AL-26396 | Comparable by category (not interchangeable 1:1) | 24 V / 5.5 Ah for Arjo lifts, including Minstrel Single and Minstrel Double; corresponds to original reference NDA0200 (not TGT223); same voltage and capacity; check fit, connector and chemistry on the specific unit. Confirmed in the distributor’s data sheet. |
There is no equivalence table validated by the manufacturer Arjo for this reference; the cross-references indicated come from biomedical battery manufacturers and specialised distributors, so it is recommended to consult the technical department before use in tendering.
5. Selection tips and variants of interest
- Confirm the exact model of the equipment: this battery corresponds to Arjo reference TGT223 for the Minstrel system. According to authorised distribution, the same pack is used in Arjo/Medibo Excelsior, Gemini and Minerva verticalisers. Do not install it in other models of the Arjo family that use packs of different voltage or capacity (e.g. Maxi Twin with NEA0100 of 12 V) without prior technical validation.
- Check the chemistry of the batch: check on the label whether the installed pack is Ni-MH or sealed lead-acid (SLA/VRLA AGM) and use the charger set for that chemistry. Do not install a battery of a different chemistry or voltage even if the connector might appear compatible.
- Replace upon signs of wear: clearly reduced autonomy, premature low battery warnings or slow lifting indicate that the battery has reached the end of its service life (typically 2-3 years depending on intensity of use).
- Storage: if the lifter is to remain unused for long periods, recharge it periodically (every 2-3 months) and avoid deep discharges. At the end of its service life, dispose of the battery at a WEEE collection point; never discard it as household waste.
- Variants in our catalogue: we offer the original version of this same reference (Ref. 88888784), the compatible Arjo NDA0100 battery (Ref. 88881140, 24 V / 4 Ah, also valid for Minstrel), the Arjo Sarita KTA0102 battery (Ref. 88881143, 24 V / 2.3 Ah), the Arjo Maxi Twin NEA0100 battery (Ref. 88881142 and 88888563, 12 V / 2.7 Ah) and the Arjo Tempo KPA0100 battery (Ref. 88881141 and 88888033, 12 V / 2.7 Ah).
- Always order by reference: quote code 88889873 or the reference stamped on the mounted battery (TGT223) to avoid confusion with other batteries in the Arjo family.
- Institutional orders: for consortia, tenders or maintenance contracts, contact our technical-commercial team at Cahnos to confirm exact compatibility with your batch of lifters and obtain a formal quotation with special volume conditions.





Reviews