Description
1. The reliable power source for your Medela Vario suction unit
The Medela Vario battery (Ref. 88888865) is the rechargeable spare part intended to restore full operability to the Medela Vario 8 and Vario 18 suction units, portable suction equipment widely used in emergency care, ambulances, hospital wards and home care. Manufactured with nickel-metal hydride (Ni-MH) technology and a nominal voltage of 12 V, it provides a stable, high-performance power source so that the unit maintains its suction vacuum without relying on the mains.
It is a rechargeable replacement part, direct to install and maintenance-free, offering a very advantageous price-performance ratio compared to the official spare part. It is the usual choice for device fleets, preventive maintenance purchases and ongoing supply contracts.
2. Technical explanation: how this battery works
The Medela Vario suction unit is a self-contained secretion suction device that operates by means of a vacuum pump driven by an electric motor powered by a rechargeable battery pack. This 12 V Ni-MH battery supplies the energy needed to generate the vacuum that extracts mucus and body fluids through the catheter and suction tubing, collecting them in the collection canister without the professional needing a mains outlet.
Ni-MH chemistry offers good energy density in a compact format and does not exhibit the memory effect characteristic of older Ni-Cd chemistries, resulting in more stable performance and a longer pack service life. Reference 88888865 belongs to the Medela original battery family and is documented in the spare parts market alongside other equivalent OEM numbers for the same component (02217, EE090305, 919.0012 and 0777.1728), used depending on the region and unit batch.
3. Technical Specifications
Technical data of the pack verified against specialised distribution documentation and the European medical spare parts market:
| Characteristic | Specification |
| Reference Cahnos (SKU) | 88888865 |
| Manufacturer reference (Medela) | 88888865 (other OEM part numbers for the same component: 02217, EE090305, 919.0012, 0777.1728) |
| Battery type | Ni-MH (nickel-metal hydride), rechargeable |
| Nominal voltage | 12 V |
| Nominal capacity | 2.0–2.1 Ah (2000–2100 mAh) depending on version; ~24 Wh |
| Approximate dimensions | 84 × 35 × 50 mm (approx., depending on batch) |
| Approximate weight | 0.37 kg |
| Rechargeable | Yes |
| Compatible equipment | Medela Vario, Vario 8 and Vario 18 secretion suction units (incl. Vario 18 Suction Pump 077.1728); check compartment and connector |
| Installation | Directly in the battery compartment, without tools |
| Use | Suction of secretions in hospitals, emergency departments, ambulances and home care |
| Presentation | Unit |
4. Equivalences and Cross-References
Reference 88888865 is a Medela OEM number consistently documented in the spare parts market as the battery for the Vario 8, Vario 18 and Vario 18 Suction Pump 077.1728 units. The other brand references listed below belong to the same product category (12 V Ni-MH rechargeable pack for Medela Vario suction units) and have been verified against manufacturer and authorised distributor datasheets; they are classified as comparable by category, not 1:1 interchangeable, and require verification of the connector, dimensions and polarity against the specific unit batch before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Unipower (OSI Batteries) | Medical Replacement Battery Vario 18 | B11999 | Comparable by category (not interchangeable 1:1) | Rechargeable pack 12 V / 2.1 Ah Ni-MH documented as a substitute for Medela 0771728 for the Vario 18 suction unit. Confirmed in manufacturer/specialised distributor datasheet; check connector and compartment dimensions. |
| Cameron Sino | Medical Replacement Battery | CS-MEV180MD | Comparable by category (not interchangeable 1:1) | Rechargeable pack 12 V / 2000 mAh (24 Wh) Ni-MH documented as a replacement for Medela EE090305, 02217, 88888865 and 919.0012 for Vario 8 / Vario 18. Confirmed in authorised distributor datasheets; check connector and dimensions. |
There is no manufacturer-validated equivalence table authorising third-party batteries for Medela Vario suction units; consult the technical department before use in a tender. Before accepting an alternative battery, the following must be verified point by point: voltage (12 V), capacity (2.0–2.1 Ah), chemistry (Ni-MH), compartment dimensions and connector type.
5. Selection tips and variants of interest
Identify the exact model of your unit: this battery is the one intended for Medela Vario 8, Vario 18 and Vario 18 Suction Pump (077.1728) suction units, under OEM numbers 88888865, 02217, EE090305, 919.0012 and 0777.1728. Do not swap it for packs of another voltage or chemistry without technical validation: an incorrect replacement can damage the device’s charging system.
Purchase planning: rechargeable batteries are consumables subject to wear from use. It is recommended to have at least one spare unit per device for preventive maintenance and to avoid downtime during shifts and emergencies.
Maintenance: if the unit is to remain unused for a long period, store it with the battery charged and perform a periodic recharge (every 2–3 months) to avoid deep discharge. Excessive heat shortens the life of the cells. At the end of its service life, dispose of the pack at a WEEE collection point.
Variants of the same family on Cahnos: rechargeable packs for other portable suction units, such as the Asskea DC30 (SKU 88888039), Weinmann Accuvac Rescue MFR WM11647 (SKU 88888639), ATMOS Atmoport 2-S (SKU 88888043) or Laerdal LSU (SKU 88888966). They are not interchangeable with this reference without technical verification.
For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility with your equipment batch, lead times and formal quotation.