Description
1. Reliable power for your Asskea M30W suction unit
At Cahnos we offer the lithium-ion battery for the Asskea M30W mucus suction unit (manufacturer reference MFR 305033, Cahnos ref. 88888804), the power supply spare part indicated to restore full operability to one of the reference portable secretion suction units in healthcare. It reproduces the performance of the device’s original pack so that your unit recovers its full autonomy without the need to change the device.
This is a rechargeable, maintenance-free spare part with direct installation, intended for maintenance services, biomedical engineering and hospital purchasing departments, as well as for device fleets under continuous supply contracts.
2. Technical explanation: how this battery works
The Asskea M30W is a self-contained secretion suction unit that operates by means of a vacuum pump driven by an electric motor powered by a removable battery pack. This lithium-ion battery supplies 11.1 V nominal and a capacity of 4400 mAh to generate the vacuum —up to −90 kPa according to the device manufacturer’s data— that extracts mucus and bodily fluids through the catheter and suction tube, collecting them in the 1-litre collection jar without the professional depending on a mains socket.
Li-ion chemistry offers high energy density in a lightweight format, a stable discharge curve and does not exhibit the memory effect characteristic of older Ni-Cd chemistries, resulting in more consistent performance and a longer pack service life. The battery compartment opens without tools, so the replacement can be carried out in seconds, even between procedures.
3. Technical Specifications
Pack data cross-checked against technical datasheets from specialised distribution and biomedical battery manufacturers that document reference 305033 for the Asskea M30W suction unit.
| Characteristic | Specification |
| Reference Cahnos (SKU) | 88888804 |
| Manufacturer reference (MFR) | 305033 (original battery for the Asskea M30W device) |
| Battery type | Lithium-ion (Li-ion), rechargeable, maintenance-free |
| Nominal voltage | 11.1 V (10.8 V) |
| Nominal capacity | 4400 mAh (4.4 Ah) / ≈48.8 Wh |
| Approximate weight | ≈0.30–0.32 kg (315 g according to distribution datasheet) |
| Rechargeable | Yes; with the device’s own power supply or charger |
| Device autonomy | Up to 40 minutes of operation in battery mode (according to manufacturer’s data for the M30 family; check the IFU for the specific model) |
| Compatible equipment | Asskea M30W mucus suction unit; check compartment and connector |
| Installation | Directly in the battery compartment, without tools |
| Use | Suction of secretions in hospitals, emergency departments, ambulances and home care |
| Presentation | Unit |
| Recycling | Dispose of in accordance with WEEE regulations / recycling centre |
4. Equivalences and Cross-References
Ref. 88888804 corresponds to the standard format of the 11.1 V / 4400 mAh lithium-ion pack that powers the Asskea M30W suction unit. The documented original reference for the device is MFR 305033, consistently confirmed in European specialised distribution as the original Li-ion battery for the M30W. As a control reference, the code 305033 also appears in distribution associated with the same product numbering (reference of the original Asskea part).
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Asskea (original device battery) | M30W battery pack | 305033 | Exact reference equivalence (original part from the equipment manufacturer) | Original Li-ion pack 11.1 V 4.4 Ah; this is the part that this replacement reproduces. Check batch and connector before replacement. |
| Asskea (new-generation original battery) | M and MPlus series | 110816-O | Comparable by category (not interchangeable 1:1) | Original Li-ion 11.1 V / 5.0 Ah (55.5 Wh), approx. dimensions 15.6 × 38.9 × 69.5 mm and 0.304 kg; new-generation cell battery for the M and MPlus series which, according to authorised distribution, requires the 405081-O battery support except in the proVisio M28. Confirmed in specialised distribution datasheets; check connector and compartment housing. |
There is no equivalence table validated by the manufacturer cross-referencing this part with third parties; consult the technical department before use in tenders. In addition to the original Asskea references, the biomedical spare parts market includes manufacturers of compatible packs for the M30W (e.g. SES Batteries / Sealed Energy Systems documents an 11.1 V 4400 mAh Li-ion battery for the M30W), whose codes are not always public: always request the datasheet for the specific pack and verify one by one voltage (11.1 V), capacity (4.4 Ah), chemistry (lithium-ion), compartment dimensions and connector before replacement.
5. Selection tips and variants of interest
- Identify the exact model of your device: this battery is the one indicated for the Asskea M30W suction unit (MFR 305033). Do not swap it for packs of a different voltage or chemistry: for example, the battery for the Asskea DC30 suction unit (12 V, Ni-MH, ref. 88888039) corresponds to a different specification; an incorrect replacement can damage the device’s charging system.
- Check the reference printed on the original battery: if it matches 305033 (or the new-generation numbering 110816-O for the M/MPlus series), this spare part is the direct replacement.
- Purchase planning: rechargeable batteries are consumables subject to wear from use. It is recommended to keep at least one spare unit per device for preventive maintenance and to avoid downtime during shifts and emergency care.
- Maintenance: lithium-ion packs self-discharge slowly when stored; if the device is to remain unused for a long period, recharge it periodically (every 2-3 months) and avoid deep discharges. Excessive heat shortens the life of the cells. At the end of its service life, dispose of the pack at a WEEE collection point; never discard it as general waste.
- Variants of the same family in Cahnos: packs for other portable suction units, such as the Asskea DC30 (88888039), Weinmann Accuvac Rescue (88888639), ATMOS Atmoport 2-S (88888043), Medela Vario (88888865) or Laerdal LSU (88888966). They are not interchangeable with this reference without technical verification.
- For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility with your equipment fleet, delivery times and formal quotation.