We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Rechargeable Ni-MH battery 4.8V 2.1Ah for B. Braun Perfusor Space syringe pump | Original manufacturer ref. 8713180 / 8713180A (MFR 8713180) | Ref. Cahnos 88888697

160,00 €

Rechargeable Ni-MH battery, 4.8V and 2.1Ah for B. Braun Perfusor Space syringe and perfusion pumps (original manufacturer pack MFR 8713180 / 8713180A, Ref. Cahnos 88888697). Direct-fit spare part with automatic recharging integrated into the device, ideal for keeping infusion and perfusion running during patient transfers, prolonged procedures or power cuts in hospitals, ICUs, emergency departments, anaesthesia and patient transport. Certified for professional use and compatible with the B. Braun Space platform.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888697

Description

1. Commercial Introduction

At Cahnos we provide the 4.8V 2.1Ah rechargeable battery for the B. Braun Perfusor Space syringe pump (Ref. Cahnos 88888697), a nickel-metal hydride (Ni-MH) rechargeable battery that corresponds to the original pack from the equipment manufacturer, reference MFR 8713180 (variant with fixing 8713180A; part number 34520856 cited in distribution for the same pack). This spare part keeps infusion and perfusion running when the pump is not connected to the mains power supply, preventing treatment interruptions in anaesthesia, intensive care, oncology, emergency and hospitalisation units. Available with fast delivery and suitable for medical electronics maintenance programmes and institutional orders.

2. Technical explanation of the equipment and the battery

The B. Braun Perfusor Space is an electronic syringe infusion pump for professional use, designed for intermittent or continuous administration of parenteral and enteral fluids via clinically accepted routes (anaesthetics, sedatives, analgesics, catecholamines, anticoagulants, etc.), intended for use in healthcare facilities, home or outpatient care and medical transport environments. To ensure therapy continuity when the patient is mobilised or during transfers without mains power, the device incorporates an internal rechargeable battery that recharges automatically while the pump remains connected to the mains.

This 4.8V and 2.1Ah rechargeable battery is a Ni-MH (nickel-metal hydride) chemistry pack, cadmium-free and with very low memory effect, which delivers the nominal voltage required by the perfusor and powers the syringe advance motor and the control circuits. When the battery life drops noticeably or the device warns of low battery prematurely, it is time to replace the rechargeable battery with this reference. According to the official B. Braun catalogue, the “Battery pack SP (NiMH)” (8713180) is a reusable, non-sterile and latex-free accessory, compatible with the Space platform: Perfusor Space, Infusomat Space, Space PCA, SpaceStation and SpaceCover Comfort.

3. Technical Specifications

Parameter Specification
Reference Cahnos (SKU) 88888697
Original manufacturer reference 8713180 (MFR 8713180); variant with fixing 8713180A; 34520856 cited in distribution for the same pack
Accumulator type Ni-MH (nickel-metal hydride), rechargeable
Nominal voltage 4.8 V
Nominal capacity 2.1 Ah (2100 mAh)
Approximate energy ≈ 10.08 Wh
Approximate dimensions of the pack ≈ 106 x 30 x 40 mm (according to authorised distribution technical data sheets; verify with the mounted part)
Approximate weight ≈ 0.20 kg
Compatibility Syringe and perfusion pumps B. Braun Perfusor Space; Infusomat Space; Space PCA; SpaceStation and SpaceCover Comfort stations (Space platform)
Recharge Automatic, integrated in the pump when connected to the mains
Installation Direct replacement in the equipment compartment, without tools
Reusable / sterility Reusable; non-sterile; latex-free (according to official B. Braun catalogue)
Intended use Hospitals, clinics, ICUs, emergency departments, anaesthesia and patient transport
Presentation 1 unit
Recycling Manage in accordance with WEEE regulations

4. Equivalences and Cross-References

Ref. Cahnos 88888697 corresponds to the original pack from the equipment manufacturer, 8713180 (B. Braun, “Battery pack SP (NiMH)”), with the variant with fixing 8713180A and the part number 34520856 consistently cited by the authorised technical distribution for the same pack. The alternatives from other manufacturers and suppliers listed below have been cross-checked against battery manufacturers’ technical data sheets and authorised distribution catalogues; they are not official B. Braun references and must be validated before replacement (voltage, chemistry, capacity, dimensions, connector type and terminal orientation according to batch).

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Axcom Power Solutions NiMH battery for B|Braun Perfusor Space / Infusomat Space (original, with fixing) MB1126MP-O Comparable by category (not interchangeable 1:1) Ni-MH 4.8V / 2.1Ah, 106 x 30 x 40 mm, with fixing pin, includes declaration of conformity; EAN 4260201684003; OEM 8713180A; verified in the manufacturer’s data sheet; connector and terminal to be checked against the mounted part.
Axcom Power Solutions Replacement cells for B|Braun Perfusor Space / Infusomat Space MBU1126 Comparable by category (not interchangeable 1:1) Ni-MH 4.8V / 2.1Ah; EAN 4260201681705; replacement cell pack that requires assembly onto the original housing; verified in the manufacturer’s data sheet; it is not a complete pack.
OSI Batteries (Unipower) Rebuilt biomedical battery for B. Braun SPACE Infusion Pump System B11659 Comparable by category (not interchangeable 1:1) Ni-MH 4.8V / 2.1Ah; replaces OEM number 8713180; verified in the manufacturer’s data sheet; “rebuild” type battery on original pack, not a new factory pack.
Medical battery suppliers (TopBattery / Battery-Mall) Compatible battery for B.Braun Infusomat Space / Perfusor Space / Perfusor Space PCA SL80190-1 Comparable by category (not interchangeable 1:1) Ni-MH 4.8V / 2100mAh, 106 x 30 x 40 mm, 200 g; replaces 8713180 and 02127; distribution reference code (not manufacturer), consistent across several technical stores; verify connector and housing before replacing.

There is no equivalence table validated by the manufacturer (B. Braun) that cross-references this part with third-party batteries on a 1:1 basis; the references listed have been verified against battery manufacturers’ technical data sheets and authorised distribution catalogues, but 1:1 replacement must be validated field by field (chemistry, voltage, capacity, dimensions, connector type and terminal orientation) before use in tenders. Consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Confirm the exact pump model: this 4.8V / 2.1Ah battery is the one for the B. Braun Space platform (Perfusor Space, Infusomat Space, Space PCA, SpaceStation and SpaceCover Comfort). Do not use it in other models of the Perfusor family with a different voltage or connector (FT/P, FM/D, Compact), even if the compartment may look similar.
  • Respect the voltage: do not use batteries of other voltages (3.6V, 7.2V, etc.) in the Perfusor Space even if the connector might fit; the device requires 4.8V nominal.
  • Replace upon signs of wear: clearly reduced battery life or low-battery warnings within a few hours of charging indicate that the battery has reached the end of its service life. Perform a full charge after installation and avoid repeated deep discharges.
  • Always order by reference: quote code 88888697 or the original equipment reference (8713180 / 8713180A) to avoid confusion with other batteries in the B. Braun family.
  • For mixed fleets: in our catalogue of batteries for infusion and perfusion pumps we have spare parts for Perfusor FT/P (88888066), Perfusor FM/D (88888064), Perfusor Compact (88888067) and Infusomat FMS (88888062) from B. Braun, as well as for other families on the market.
  • Institutional orders: for tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and a formal quotation.

Additional information

Manufacturer reference

8713180 (MFR 8713180); variant with fixing 8713180A; 34520856 cited in distribution

Accumulator type

Ni-MH (nickel-metal hydride), rechargeable

Nominal voltage

4.8 V

Nominal capacity

2.1 Ah (2100 mAh / ≈10.08 Wh)

Dimensions

≈ 106 x 30 x 40 mm (according to distribution technical data sheets; verify with the mounted part)

Approximate weight

≈ 0.20 kg

Compatibility

Perfusor Space, Infusomat Space, Space PCA, SpaceStation and SpaceCover Comfort (Space platform by B. Braun)

Recharge

Automatic, integrated in the pump when connected to the mains

Installation

Direct replacement in the equipment compartment, without tools

Use

Hospitals, clinics, ICUs, emergency departments, anaesthesia and patient transport

Recycling

RAEE/WEEE

Reusable

Yes (non-sterile, latex-free)

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Rechargeable Ni-MH battery 4.8V 2.1Ah for B. Braun Perfusor Space syringe pump | Original manufacturer ref. 8713180 / 8713180A (MFR 8713180) | Ref. Cahnos 88888697”

Your email address will not be published. Required fields are marked *