Description
1. Factory power for your Welch Allyn LXI monitor
This original Welch Allyn LXI MFR 105632 battery (ref. Cahnos 88881196) is the factory replacement that keeps your Spot Vital Signs LXI vital signs monitor always operational, with the same reliability and performance as the unit fitted at the factory. Designed for the LXI platform, it provides a stable, rechargeable power source that allows continued measurement of non-invasive blood pressure, oxygen saturation, pulse rate and temperature even when the device is moved between consulting rooms, between wards or during a power supply interruption.
A solution designed for institutional purchasing: an original replacement, simple to install and available so that the maintenance department always has a spare to hand and the monitor never goes out of service. In fleets with several LXI devices, having this reserve battery avoids monitoring downtime and extends the service life of the monitor fleet.
2. Technical explanation
The Welch Allyn Spot Vital Signs LXI series monitors (models 45NT0-E1, 45NE0-E1, 45MT0-E1, 45ME0-E1, 450E0-E1 and 450T0-E1) are compact bedside and transport devices that integrate vital signs measurement into a single unit. When operating without mains power —in emergency departments, triage, consulting rooms or internal transfers— the internal battery ensures continuity of monitoring and prevents restarts or loss of patient data.
This reference uses rechargeable Ni-MH (nickel-metal hydride) chemistry, with a nominal voltage of 6.4V and a capacity of 6Ah, which translates into 38.4Wh of available energy. Once installed in the device compartment, the monitor recharges it automatically when connected to its power supply, without the need for external chargers or specialised tools. When the battery life noticeably reduces or the device warns of low battery after a few hours of charging, it is time to replace the accumulator.
3. Technical Specifications
| Specification | Detail |
|---|---|
| Application | Vital signs monitor Welch Allyn LXI / Spot Vital Signs LXI (platform associated with ref. 105632) |
| Original reference (MFR) | 105632 |
| Reference Cahnos (SKU) | 88881196 |
| Technology | Ni-MH (nickel-metal hydride) rechargeable |
| Nominal voltage | 6.4 V |
| Capacity | 6 Ah (6,000 mAh) |
| Energy | 38.4 Wh |
| Weight | Approximately 0.45 kg |
| Dimensions | 100 x 75 x 40 mm |
| Load | Automatic in the monitor (rechargeable) |
| Device manufacturer | Welch Allyn |
| Presentation | 1 unit |
| Recycling | WEEE |
Technical note: the original reference 105632 from Welch Allyn is documented in regulatory databases (GUDID) and in specialist distribution catalogues as a lithium-ion (Li-ion) pack of 6.4V 6Ah. This datasheet corresponds to the Ni-MH variant of 6.4V 6Ah; before replacing a battery in service, confirm that the monitor’s charging circuit accepts Ni-MH chemistry.
4. Equivalences and Cross-References
Reference 105632 is the code under which Welch Allyn identifies the internal battery of the Spot Vital Signs LXI platform. In the replacement market, the same application is covered by replacement battery manufacturers that declare they replace the 105632 (codes verified in public specialist distribution catalogues). The references listed below are classified as comparable by category (not 1:1 interchangeable) and must be verified one by one —voltage, capacity, chemistry, connector and dimensions— against the specific unit before replacement.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| OSI Batteries (Unipower) | Welch Allyn LXI medical series | B11848 | Comparable by category (not interchangeable 1:1) | Declared replacement for the 105632 for LXI monitor; Li-Ion 6.4V 6Ah; verify connector and chemistry with respect to the charging circuit. |
| Cameron Sino Technology | Welch Allyn LXI medical series | CS-WB632SL | Comparable by category (not interchangeable 1:1) | LiFePO4 6.4V 7,200 mAh (46.08 Wh); declared dimensions ≈97.5 x 67.2 x 39.7 mm; capacity and chemistry different from the Ni-MH variant in this datasheet. |
| Cables and Sensors | Welch Allyn LXI medical series | MED3445 / 11490 | Comparable by category (not interchangeable 1:1) | Li-Ion 6.4V 6Ah; declared for Spot Vital Signs LXI (45NT0-E1, 45NE0-E1, 45MT0-E1, 45ME0-E1, 450E0-E1, 450T0-E1); verify chemistry and connector. |
There is no equivalence table validated by the manufacturer (Welch Allyn / Hillrom) that authorises the direct cross-reference between the original reference 105632 and the third-party codes cited; they are listed as documentary support and must be verified against the equipment in service. Consult the technical department before using this reference in a tender or replacing the battery of a monitor in use.
5. Selection tips and variants of interest
Verify the exact monitor model: this battery corresponds to the Welch Allyn LXI / Spot Vital Signs LXI platform associated with reference 105632 (models 45NT0-E1, 45NE0-E1, 45MT0-E1, 45ME0-E1, 450E0-E1 and 450T0-E1). Also confirm the label of the installed battery. Do not install it in other families such as VSM300, VSM6000, Spot Connex or Propaq without confirming compatibility: each device accepts a specific voltage, capacity and geometry.
Confirm the charger chemistry: this datasheet describes the Ni-MH 6.4V 6Ah variant. If your monitor was working with the original cell documented as Li-ion, verify that the charging circuit accepts Ni-MH before installing.
Spare rotation: in fleets with several LXI monitors, keep a reserve battery charged and rotate its use to extend the service life of the set. Ni-MH batteries self-discharge at rest; if the device is to remain off for long periods, carry out periodic recharging to avoid deep discharges.
Other Welch Allyn variants at Cahnos: compatible LXI battery 6.4V 6Ah (ref. 88889726), 6V 6Ah battery for Vital Sign Spot LXI (MFR 4500-84-1, ref. 88888799), 6V 4.5Ah battery for Vital Signs VSM300 (MFR 407560, ref. 88888655), 7.2V 3.2Ah battery for Spot Connex (MFR BATT22, ref. 88889217) and 6.4V 6Ah battery for Spot / Spot Vital Signs 420 (MFR 105631, ref. 88889216). Do not interchange these references between models: each device accepts a specific voltage, capacity and geometry.
For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and a formalised quotation.