1. Reliable power for your CodeMaster defibrillator-monitor
The Philips/Laerdal CodeMaster 12 V, 4.5 Ah battery (commercial reference M1724A) is the replacement your defibrillator-monitor needs to be always ready when it matters most. Designed as a direct substitute for the original Philips M1758A battery, it maintains the same sealed lead-acid chemistry, the same nominal voltage and the same capacity, so the equipment retains its usual performance, weight and autonomy without needing to modify the battery compartment or the charger. A reliable and economical replacement solution for emergency services, out-of-hospital emergencies, mobile ICUs and critical care units that need to keep their fleet of resuscitation equipment operational.
2. Operation and technical explanation
The Philips/Laerdal CodeMaster defibrillator-monitor operates on mains power or internal battery when transporting the patient, during monitoring in ambulances or in procedures without a nearby power outlet. This sealed lead-acid battery (SLA/VRLA, maintenance-free) supplies 12 V nominal and 4.5 Ah capacity, providing the energy needed for ECG monitoring, defibrillation and continuous recording functions.
Being a sealed battery, it requires no electrolyte replacement or special ventilation: it recharges automatically when the device is docked in its base or connected to the mains, and alerts via the defibrillator’s own charge indicator. It is the type of accumulator recommended by the manufacturer for this series, due to its stable current response and predictable behaviour in the charge and discharge cycles typical of clinical use.
3. Technical Specifications
| Battery type | Sealed lead-acid (SLA/VRLA), maintenance-free |
| Nominal voltage | 12 V |
| Nominal capacity | 4.5 Ah |
| Nominal energy (calculation) | 12 V x 4.5 Ah = 54 Wh |
| Reference Cahnos | 88888253 |
| Equipment commercial reference | M1724A (CodeMaster XE) |
| Original manufacturer reference | M1758A / MLA1758A |
| Compatible models | CodeMaster XE (M1724A), CodeMaster XL (M1723A/B), CodeMaster XL+ (M1722A/B) and CodeMaster M1758A |
| Dimensions | 140 x 46 x 110 mm |
| Approximate weight | 1.33 kg |
| Accumulator type | Rechargeable, sealed, non-spillable |
| Use | Defibrillator-monitor for emergency departments, emergency care and critical care |
| Maintenance | Maintenance-free; automatic recharging in base |
| Recycling | Management in accordance with WEEE regulations |
4. Equivalences and Cross-References
Technical note on nomenclature: M1724A is the model of the CodeMaster XE defibrillator-monitor; the official reference for the original Philips battery for the entire M17xx series is M1758A (also cited as MLA1758A). The market distributes this battery as “M1724A” because it is the most common target device. The Cahnos reference 88888253 corresponds to this same 12 V, 4.5 Ah battery. The third-party cross-references listed below belong to the same product category (SLA biomedical battery 12 V / 4.5 Ah for the CodeMaster M17xx series) and have been verified in specialised biomedical distribution datasheets; they are classified as comparable by category, not 1:1 interchangeable, and require verification of connector, terminals and dimensions before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Philips (original manufacturer) | OEM battery for CodeMaster M17xx series | M1758A / MLA1758A | Exact reference equivalence (same manufacturer) | Original factory battery for CodeMaster XE (M1724A), XL (M1723A/B), XL+ (M1722A/B) and M1758A. Same SLA chemistry, 12 V and 4.5 Ah. |
| OSI Batteries (Unipower) | Biomedical battery for CodeMaster M17xx | B10782 | Comparable by category (not interchangeable 1:1) | 12 V, 4.5 Ah, sealed lead; confirmed in specialised biomedical distributor datasheet as replacement for M1758A. Verify connector and terminals before installation. |
| Alpha Source / Dixon Med | SLA replacement for CodeMaster | AS10782 | Comparable by category (not interchangeable 1:1) | 12 V, 4.5 Ah with connector, for CodeMaster 1722A/B, 1723A/B, 1724A/XE and 1758A; documented in authorised biomedical distribution. Confirm terminal and polarity. |
| R&D Batteries / BBM Battery | SLA replacement for CodeMaster | 5582 | Comparable by category (not interchangeable 1:1) | 12 V / 4.5 Ah (4500 mAh), drop-in for M1758A for CodeMaster XL+ and 1723A/B; consistently cited in biomedical compatibility tables. Verify format and terminals. |
| Interstate Batteries | Biomedical SLA 12 V range | AMED9106 | Comparable by category (not interchangeable 1:1) | Cross-reference of 12 V / 4.5 Ah included alongside B10782, AS10782 and 5582 in specialised distribution tables for the CodeMaster M17xx family. Check connector of the batch. |
There is no officially validated equivalence table from the manufacturer that cross-references this part with third-party batteries; the codes B10782, AS10782, 5582 and AMED9106 come from distributors specialised in biomedical batteries and must be checked with the technical department before use in tenders or replacement of an in-service device.
5. Selection tips and variants of interest
- Before ordering, confirm the exact model engraved on your defibrillator label: M1722A/B (XL+), M1723A/B (XL), M1724A (XE) or M1758A. All accept this 12 V battery.
- If your device shows the low battery indicator, replace the accumulator before a full discharge could affect the monitoring recording during a transfer.
- Keep the battery charged: when idle, periodically check the level and perform charge cycles if the device remains unused for a long time. Sealed lead batteries lose charge slowly in storage.
- Store in a cool, dry place, protected from direct sunlight and extreme temperatures, as recommended by the manufacturer’s technical data sheet.
- Variants of interest: for other Philips/Laerdal defibrillators, Cahnos offers batteries such as 88888255 (HeartStart XL, M3516A), 88888328 (HeartStart FR2, M3863A), 88888342 (HeartStart HS1, M5070A) and 88888363 (HeartStart MRx, M3538A).
- If you have any doubts about compatibility with your batch of devices, contact our technical department before placing the order.