Description
1. Original reserve power for your Nihon Kohden electrocardiograph
Keep your Nihon Kohden Cardiofax ECG-1500 or ECG-1550 electrocardiograph always operational with this original brand battery, factory reference X073 (Ref. Cahnos 88888765). Designed specifically for the Cardiofax electrocardiographic recording platform, its 12V high-capacity nickel-metal hydride (Ni-MH) chemistry supplies stable, continuous power during prolonged recording sessions, in-hospital transfers and primary care examinations, without depending on the mains supply.
As an OEM replacement from Nihon Kohden, it guarantees full compatibility with the equipment, factory performance, energy efficiency and a long service life, with the technical and commercial support of Cahnos for institutional purchases, equipment fleets and tenders.
2. How this battery works: technical explanation
The portable Nihon Kohden Cardiofax electrocardiographs of the ECG-1500 and ECG-1550 series are 12-lead recording devices capable of operating connected to the mains or powered by their internal rechargeable battery. While the device is plugged in, the battery remains in charging mode; when it is disconnected, moved or in the event of a power cut, it automatically takes over powering the recording electronics, the display and the thermal printer without interrupting the trace.
The Ni-MH chemistry delivers a stable 12V voltage with 3.6Ah nominal capacity (approx. 43.2 Wh), enough to complete multiple electrocardiographic studies without depending on the mains. It is a maintenance-free cell with very low memory effect and tolerance to repeated charge/discharge cycles. A degraded cell manifests itself through loss of autonomy, low-battery warnings or shutdowns during recording; preventive replacement with this reference restores the device’s original performance in a few minutes. Reference X073 is the factory code of Nihon Kohden, which in service documentation and specialist distribution is also designated as SB-150D.
3. Technical Specifications
Data cross-checked against the technical documentation of the original Nihon Kohden X073 / SB-150D cell, the specialist distribution network and the internal reference register of Cahnos:
| Parameter | Detail |
| Reference Cahnos (SKU) | 88888765 |
| Nihon Kohden factory reference | X073 (OEM code: SB-150D) |
| Type / technology | Original rechargeable nickel-metal hydride (Ni-MH) battery, maintenance-free |
| Nominal voltage | 12 V |
| Capacity | 3.6 Ah (3600 mAh) – approx. 43.2 Wh; compatible packs on the market up to 3.8 Ah (45.6 Wh) |
| Approximate dimensions | Approx. 140 × 22 × 93 mm (original X073 / SB-150D cell approval) |
| Approximate weight | Approx. 0.6 kg |
| Rechargeable | Yes, via the electrocardiograph’s integrated charger |
| Compatibility | Nihon Kohden Cardiofax ECG-1400, ECG-1450, ECG-1500, ECG-1500K, ECG-1510, ECG-1530, ECG-1550, ECG-1550K, ECG-1550P and ECG-1560 (X073 / SB-150D pack family, according to specialist distribution) |
| Mounting type | Direct replacement in the battery compartment, without adapters or tools |
| Presentation | 1 unit |
| Recycling | Do not dispose of as municipal waste; recycle in accordance with RAEE/WEEE regulations |
4. Equivalences and Cross-References
Factory reference X073 corresponds to the 12V 3.6Ah Ni-MH pack that Nihon Kohden fits in the Cardiofax ECG-1500/1550 and family; in service documentation and the specialist distribution network it is consistently cited in association with OEM code SB-150D. Nihon Kohden does not publish an official equivalence table authorising third-party batteries; the alternatives indicated share chemistry (Ni-MH), voltage (12V) and capacity range (3.6–3.8Ah), but are classified as comparable by category, not 1:1 interchangeable, and require verification of connector, dimensions and batch against the specific device before replacement.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Nihon Kohden (factory designations) | Cardiofax ECG-1500 / ECG-1550 and family | X073 = SB-150D | Exact reference equivalence (same manufacturer) | OEM designations of the same 12V 3.6Ah Ni-MH battery, consistently confirmed in service documentation and specialist distribution. |
| Cameron Sino Technology (Medical) | Ni-MH battery for Nihon Kohden Cardiofax ECG-1500 / 1550 and family | CS-NK1450MD (EAN 4894128070481) | Comparable by category (not interchangeable 1:1) | Ni-MH 12V, 3800 mAh (45.6 Wh), blue, net weight approx. 521 g. Different manufacturer (not original Nihon Kohden); replaces OEM SB-150D / X073. Higher nominal capacity; verify connector, dimensions and batch. |
There is no equivalence table validated by the manufacturer (Nihon Kohden) authorising third-party batteries for reference X073 / SB-150D; consult the technical department before using in a tender. As a reference, specialist distribution supplies this same configuration (12V, 3.6–3.8Ah, Ni-MH) under OEM codes X073 / SB-150D and the alternative reference cited, which must always be verified against the installed cell.
5. Selection tips and variants of interest
Before replacing the battery in your electrocardiograph, check three parameters on the label of the removed cell: voltage (12V), technology (Ni-MH) and factory reference (X073 or SB-150D). If your device is a Cardiofax ECG-1500, ECG-1550 or another model in the same family (ECG-1400, ECG-1450, ECG-1500K, ECG-1510, ECG-1530, ECG-1550K, ECG-1550P, ECG-1560), this reference is the appropriate one.
Do not confuse it with other batteries in the Nihon Kohden family: each platform uses its own X0xx code. In the Cahnos catalogue you will find the X065 Ni-MH 12V 3Ah for ECG-1350 electrocardiographs (Ref. 88888843) and Cardiolife TEC-7600 defibrillators (Ref. 88888424), the X041B lead-acid 12V 2.9Ah for Cardiofax ECG-4201/6000 (Ref. 88888425), the X041A lead-acid 12V 2.3Ah for Cardiofax ECG-8023G (Ref. 88888423) and the X071 Ni-MH 12V 2Ah for Cardiofax 1250/9620/9629 (Ref. 88888426). Only one variant fits each device: always check the fitted cell before buying.
Preventive maintenance: Ni-MH cells self-discharge slowly at rest; if the device is to remain switched off for long periods, recharge it periodically and avoid repeated deep discharges so as not to shorten its service life. After replacement, fully charge the battery before first use and allow the device to complete its power-on self-test. For tenders and equipment fleets, contact our technical department stating the model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order and offer special terms for volume.