Description
1. Commercial Introduction
The Cardio E3 Akku battery from medical ECONET is the original lithium-ion (Li-ion) accumulator designed for the 3-channel electrocardiograph Cardio E3 (ref. 30.30-2100). It is the spare part that keeps your equipment fully operational when working in battery mode: electrocardiographic recording without depending on a mains socket, both in cardiology clinics and in emergency services, primary care, occupational medicine and mobile use. As it is the manufacturer’s reference battery, it ensures a fit and performance consistent with the original design of the equipment.
2. Technical Explanation
The Cardio E3 electrocardiograph incorporates an internal rechargeable battery that powers the equipment when it is disconnected from the mains. While the electrocardiograph remains connected to the power supply, the battery stays charged; if the supply fails or the equipment is moved to attend to the patient, the battery automatically takes over the power supply without interrupting the examination.
This battery uses lithium-ion (Li-ion) chemistry, which offers high energy density, low self-discharge and a stable discharge curve, with less memory effect than nickel technologies. It delivers a nominal voltage of 14.4 V and a capacity of 2,600 mAh, providing 37.44 Wh of useful energy to keep the recording, screen and thermal printer of the equipment running during scheduled sessions. Charging management is carried out in an integrated manner through the electrocardiograph itself, respecting the Li-ion charging parameters.
3. Technical Specifications
The verified technical data from the manufacturer’s catalogue are detailed below:
| Characteristic | Technical data |
|---|---|
| Product | Cardio E3 Akku rechargeable battery (Li-ion) |
| Brand | medical ECONET |
| Manufacturer / original distributor | medical ECONET GmbH |
| Chemistry | Li-ion (lithium-ion) rechargeable |
| Capacity | 2,600 mAh |
| Nominal voltage | 14.4 V |
| Energy | 37.44 Wh |
| Charging voltage | 16.8 V |
| Compatible equipment | Electrocardiograph Cardio E3 (ref. 30.30-2100), Cardio range from medical ECONET |
| ECONET category | ECG | Electrocardiography | Accessories (accessories for electrocardiography) |
| Intended use | Portable power supply for the electrocardiograph for 12-lead ECG recording |
| Presentation | 1 unit |
| Recycling | Management in accordance with WEEE regulations |
Available references
| Reference | Description |
|---|---|
| MEC31.30-2105 | Cardio E3 Akku battery (Li-ion, 14.4 V / 2,600 mAh) · Distribution SKU/reference Cahnos |
| 31.30-2105 | Article number medical ECONET of the same battery |
4. Equivalences and Cross-References
This product is marketed under the references MEC31.30-2105 (distribution Cahnos) and 31.30-2105 (article number medical ECONET), which identify the same battery. There is no manufacturer-validated equivalence table that cross-references this reference with third-party batteries on a 1:1 interchangeable basis: it is a proprietary spare part for the Cardio E3 electrocardiograph, so the performance, connector and charge management system must be exactly those of the original design. Before any replacement with generic or other-brand accumulators, consult our technical-commercial department.
Within the same catalogue of medical ECONET distributed by Cahnos, you can complete the equipment of your Cardio E3 electrocardiograph with the following items from the same family: the Cardio E3 3-channel electrocardiograph with 12 leads (ref. 30.30-2100) and the CARDIO E3 thermal paper of 80 mm (ref. MEC70.30-2101 / 70.30-2101).
5. Selection tips and variants of interest
Confirm the model of the equipment: this battery is exclusive to the Cardio E3 electrocardiograph (ref. 30.30-2100) from medical ECONET. Before ordering, verify that your equipment corresponds to this model and check the reference printed on the removed battery.
Symptoms of a depleted battery: if the Cardio E3 shows clearly reduced autonomy, does not hold a charge or switches off during the examination, it is time to replace the internal battery with this original reference. Periodic replacement of the Li-ion battery is part of the usual preventive maintenance of the equipment and prevents interruptions to the diagnostic service.
Storage and environmental management: keep the battery in a cool, dry place until installation and follow the instructions in the equipment manual. Deliver the depleted battery to a specialised collection point (WEEE); do not dispose of it in the general waste container. For institutional orders, equipment fleets or tenders, contact the technical-commercial department of Cahnos to confirm exact compatibility and obtain a formal quotation.





Reviews