Original Battery Fukuda Denshi for Electrocardiograph CardiMax FCP-7101 / FX-7102 · Factory Ref. 8PH-4/3A3700-HJ1 · Ni-MH 9.6 V 4 Ah (38.4 Wh) · ECG 12-Lead Battery Replacement | Ref. 88888905

200,00 €

Original Fukuda Denshi battery for the CardiMax FCP-7101 and FX-7102 electrocardiographs, built to the factory reference 8PH-4/3A3700-HJ1 (transcribed as 8PH-4/3A3700-H-J18 and MB333BHR-4/3AU). Ni-MH chemistry with 9.6 V and 4 Ah (38.4 Wh), pack of 8 cells with connector and official construction dimensions: perfect fit in the compartment, integrated recharging by the device itself in standby mode and sufficient battery life to complete 12-lead recordings in consulting rooms, emergency departments and ambulatory diagnostics. Maximum reliability for medical electronics services and institutional purchasing, with 24-72 h dispatch and formalised quotation for tenders.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888905

Description

1. Product Presentation

The original Fukuda Denshi battery for the CardiMax FCP-7101 and FX-7102 electrocardiographs (ref. Cahnos 88888905) is the power replacement designed by the equipment manufacturer to maintain continuous diagnostics even without connection to the mains. With its Ni-MH chemistry of 9.6 V and 4 Ah, it guarantees the accuracy and stability of the electrocardiographic recording in cardiology clinics, emergency departments, health centres and ambulatory diagnostic units.

It is the direct replacement pack for the battery compartment of both devices, with the connector and dimensions of the official construction. It is supplied with immediate dispatch in 24-72 h and a formalised quotation for institutional purchases and tenders.

2. Technical explanation of the equipment and the battery

The Fukuda Denshi CardiMax FCP-7101 and FX-7102 are interpretive 12-lead electrocardiographs with dual power supply: mains (100-240 V AC) or, in portable mode, direct current through the rechargeable battery pack. This pack consists of a set of 8 cells of 1.2 V totalling the nominal 9.6 V, with a capacity of 4 Ah and a stored energy of 38.4 Wh, sufficient to complete electrocardiographic recording sessions, arrhythmia analysis and stress tests without the need for a mains connection.

Charging is carried out in an integrated manner: according to the manufacturer’s service documentation, when the power cable is connected to the mains and the device remains in standby mode (off), the electrocardiograph itself automatically starts charging the pack, without the need for an external charger. As it is an original battery of the brand, the mechanical fit to the compartment, the connector and the electrical parameters exactly match the factory specification, avoiding compatibility errors and voltage drops during a full examination.

3. Technical Specifications

Field Specification
Brand / compatible system Fukuda Denshi — CardiMax FCP-7101 and FX-7102 electrocardiographs (12-lead ECG); documented usual use in FX-7100, FX-7000, FX-2201, FX-8200 and FCP-8100 of the same pack format.
Original manufacturer reference 8PH-4/3A3700-HJ1 (also transcribed as 8PH-4/3A3700-H-J18 in data sheets and distribution catalogues); alternative designation MB333BHR-4/3AU
Reference Cahnos (SKU) 88888905 (original brand version); compatible version available as 88888612
Type Original brand (equipment manufacturer’s construction)
Technology Ni-MH (nickel-metal hydride) — 8-cell rechargeable pack
Nominal voltage 9.6 V
Capacity 4 Ah
Stored energy 38.4 Wh
Approximate dimensions of the pack ≈ 130 × 50 × 30 mm according to the data sheet of the original version (other sources for the same pack: 135.7 × 67.4 × 18.1 mm); verify the compartment dimension
Approximate weight ≈ 400-470 g depending on source
Connector 4 pins (original equipment pack construction)
Recharge Integrated by the electrocardiograph in standby mode with the mains cable connected
Application Resting electrocardiographic recording, stress testing and ambulatory diagnostics
Presentation 1 unit
Recycling Management in accordance with WEEE regulations

4. Equivalences and Cross-References

The official reference stamped on the original pack of the CardiMax FCP-7101 / FX-7102 is 8PH-4/3A3700-HJ1, confirmed in the internal decoding documentation of the line and transcribed in numerous data sheets and distribution catalogues as 8PH-4/3A3700-H-J18; the alternative factory designation MB333BHR-4/3AU corresponds to the same 9.6 V Ni-MH pack and is consistently associated with the same family of devices. All these transcriptions refer to the same 4 Ah pack (38.4 Wh). There is no published and validated cross-reference table by Fukuda Denshi against other manufacturers; the third-party references cited below have been checked against catalogues and data sheets of their own manufacturers or authorised distributors.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Cameron Sino Replacement battery for Fukuda Denshi FX-7102 / FCP-7101 / FX-7000 / FX-2201 / FX-8200 / FCP-8100 CS-FXD710MD Comparable by category (not interchangeable 1:1) Aftermarket replacement Ni-MH 9.6 V and 4000 mAh (38.4 Wh) with dimensions 135.67 × 67.42 × 18.11 mm and weight ≈ 470 g; replaces 8PH-4/3A3700-H-J18 and MB333BHR-4/3AU. Confirmed in catalogues of authorised distributors of the brand (Batteries America, BatteryBob, TotalBattery, Amazon UK/IT). Verify fit and 4-pin connector before replacing.

In the market there are also numerous generic replacements of 4000 mAh that declare compatibility with the FCP-7101 / FX-7102 based on the reference 8PH-4/3A3700-H-J18; they are not listed because there is no official technical data sheet verified from the pack manufacturer itself. There is no equivalence table validated by the manufacturer for this battery against other brands; consult the technical department before using in a tender.

5. Selection tips and variants of interest

Verify the reference stamped on your battery: before ordering, confirm that the pack removed from the compartment shows the reference 8PH-4/3A3700-HJ1 (or the transcriptions 8PH-4/3A3700-H-J18 / MB333BHR-4/3AU). If your device works with a different pack, do not force the replacement.

Do not mix families: Fukuda electrocardiographs from the same house use different constructions depending on the model: FX-7202 / FX-2201 / FX-7201 with a 1.7 Ah pack (ref. Cahnos 88888192), FX-2111 with a 1.7 Ah pack (ref. 88888189) and FX-7402 with a 3.8 Ah pack (ref. 88889321). This data sheet corresponds exclusively to the 4 Ah pack of the FCP-7101 / FX-7102.

Ni-MH pack maintenance: to preserve capacity, perform full charge cycles in standby and avoid prolonged deep discharges; if the device is to remain unused for several weeks, leave the battery charged and check the level periodically. If the autonomy is significantly reduced or the device warns of low battery with a recent charge, replace the pack so as not to interrupt the examination.

Variants at Cahnos: original brand version for the same device (ref. 88888905) and compatible version (ref. 88888612), in addition to the batteries for FX-7202 (88888192), FX-2111 (88888189) and FX-7402 (88889321).

Institutional purchases: for tenders, continuous supply contracts or large volumes, contact our technical-commercial department to confirm the exact reference, compatibility and formalised quotation.

Additional information

Product line

Fukuda Denshi (Cahnos line)

Manufacturer reference

8PH-4/3A3700-HJ1 (transcribed as 8PH-4/3A3700-H-J18 in catalogues; alternative MB333BHR-4/3AU)

Product type

Original brand (equipment manufacturer's construction)

Technology

Ni-MH (nickel-metal hydride) — 8-cell rechargeable pack

Nominal voltage

9.6 V

Capacity

4 Ah (4000 mAh)

Energy

38.4 Wh

Number of cells

8 cells (9.6 V pack)

Compatibility

Fukuda Denshi CardiMax FCP-7101 / FX-7102; documented habitual use in FX-7100, FX-7000, FX-2201, FX-8200 and FCP-8100 of the same pack format

Dimensions

≈ 130 × 50 × 30 mm (other catalogues: 135.7 × 67.4 × 18.1 mm); check compartment dimension

Approximate weight

≈ 400-470 g depending on source

Connector

4 pins (original equipment pack construction)

Recharge

Integrated by the electrocardiograph in standby mode with the mains cable connected

Application

Resting electrocardiographic recording, stress testing and ambulatory diagnostics

Recycling

Management in accordance with WEEE regulations

Stored energy

38.4 Wh

Approx. pack dimensions

≈ 130 × 50 × 30 mm (other catalogues: 135.7 × 67.4 × 18.1 mm); check compartment dimension

Approx. weight

≈ 400-470 g depending on source

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Original Battery Fukuda Denshi for Electrocardiograph CardiMax FCP-7101 / FX-7102 · Factory Ref. 8PH-4/3A3700-HJ1 · Ni-MH 9.6 V 4 Ah (38.4 Wh) · ECG 12-Lead Battery Replacement | Ref. 88888905”

Your email address will not be published. Required fields are marked *