Description
1. Backup power for your Defibtech Lifeline VIEW defibrillator
At Cahnos we offer the replacement battery that corresponds to the original unit of the Defibtech Lifeline VIEW defibrillators (ref. DCF-2003, also labelled DBP-2003), identified in our catalogue under reference 88888935. It is a non-rechargeable primary lithium cell of 12 V and 2.8 Ah, designed to keep the AED permanently in ‘ready-to-use’ mode for up to 4 years, with no charging routines or maintenance.
It is the essential spare part for emergency services, ambulances, civil protection, workplaces, sports facilities and public-access defibrillation points that manage Lifeline VIEW, VIEW ECG and VIEW PRO equipment, ensuring an immediate response to cardiac arrest.
2. Technical explanation: how this battery works
The automated external defibrillator (AED) Lifeline VIEW operates exclusively on battery: while in standby, the device performs daily, weekly, monthly and quarterly self-tests that check the condition of the cell, the electronics and the electrodes. In an emergency, the stored energy powers the rhythm analysis electronics, the voice prompts and the capacitor charge/discharge stage to deliver biphasic therapy.
This battery uses primary lithium chemistry (lithium-manganese dioxide type), single-use and non-rechargeable: its very low self-discharge allows it to remain installed for years with full response capacity. When depletion approaches, the device warns via a light indicator and acoustic signal; replacement is carried out by removing the exhausted battery and inserting the new one into the compartment, without tools. Due to its disposable nature, stock management must be carried out by expiry date (FIFO rotation).
3. Technical Specifications
| Parameter | Specification |
| Reference Cahnos (SKU) | 88888935 (distribution code) |
| Manufacturer reference (MFR) | DCF-2003, also labelled DBP-2003 (Defibtech) |
| Battery type | Primary lithium cell, non-rechargeable (single-use) |
| Chemistry | Lithium (lithium-manganese dioxide type, Li-MnO₂) |
| Nominal voltage | 12 V |
| Nominal capacity | 2.8 Ah (2800 mAh) |
| Stored energy | ≈ 33.6 Wh |
| Standby autonomy | Up to 4 years installed (includes unit self-tests) |
| Shock capacity | Up to 125 shocks or 8 hours of continuous monitoring |
| Rechargeable | No |
| Maintenance | Maintenance-free; replace by expiry date |
| Compatibility | Defibtech Lifeline VIEW (DDU-2300), VIEW ECG (DDU-2450), VIEW PRO and DDU-2000 series |
| Low battery warning | Visual indicator and audible signal |
| Installation | Direct replacement in the compartment, no tools required |
| Presentation | 1 unit |
| Recycling | Management in accordance with WEEE regulations (regulated lithium transport) |
Technical note: reference DCF-2003 identifies the 4-year pack supplied as standard with the Lifeline VIEW (DDU-2300) and Lifeline ECG (DDU-2450) devices; the designation DBP-2003 corresponds to the same battery and is the code under which it is registered in the GUDID regulatory database (FDA, IDs 00815098020393 and 10815098020390). Reference 88888935 is the distribution code under which this spare part is marketed.
4. Equivalences and Cross-References
The official reference for the pack is DCF-2003 / DBP-2003, confirmed both in the manufacturer’s catalogue and in the GUDID database. Defibtech does not publish an equivalence table authorising third-party batteries for the Lifeline VIEW family; the listed alternatives share the same type (lithium battery for AED) but come from other manufacturers and are classified as comparable by category, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Defibtech (equipment manufacturer) | Original Lifeline VIEW / ECG / PRO battery (DDU-2000 series) | DBP-2003 | Exact reference equivalence (same manufacturer) | It is the same battery that this datasheet reproduces: primary lithium pack 12 V / 2.8 Ah, up to 4 years in standby and 125 discharges. The designations DCF-2003 and DBP-2003 correspond to the same assembly; registered in GUDID (00815098020393 / 10815098020390). |
| AolsteCell | Replacement for DCF-2013, DDU-2000, DCF-2003, DBP-2003 and Lifeline Pro | AolsteCell DBP-2003 | Comparable by category (not interchangeable 1:1) | Third-party replacement battery that declares compatibility with the Lifeline VIEW/PRO family; verify voltage (12 V), capacity (2.8 Ah), connector and compartment housing before replacement. |
| Recell (BatteryMart) | DBP-2003-ABE battery for Lifeline VIEW AED | DBP-2003-ABE | Comparable by category (not interchangeable 1:1) | Aftermarket replacement that declares up to 125 discharges, 5 years of shelf life and 4 years of warranty; validate chemistry and mechanics against the removed unit. |
There is no equivalence table validated by the manufacturer (Defibtech) that cross-references DCF-2003 / DBP-2003 with third-party batteries; consult the technical department before use in tenders. Before accepting an alternative battery, each item must be verified one by one: voltage (12 V), capacity (2.8 Ah), chemistry (non-rechargeable primary lithium), connector and compartment dimensions. Batteries from other AEDs on the market (e.g. ZOLL AED Pro 8000-0860-01, Philips HeartStart FR3 989803150161, CU Medical CUSA0601F or Welch Allyn 1852) share the same type but are not interchangeable due to proprietary connector and management electronics.
5. Selection tips and variants of interest
Identify the exact model: this battery corresponds to the Defibtech Lifeline VIEW, VIEW ECG and VIEW PRO defibrillators (DDU-2000 series), identified by models DDU-2300 and DDU-2450. It is not compatible with the original Lifeline AED model, which uses the DBP-1400 battery.
Verify the printed reference: before ordering, confirm on the removed battery the code DCF-2003 or DBP-2003; if your device works with another pack, do not force the replacement.
Expiry management: as it is a non-rechargeable primary battery, establish FIFO stock rotation and replace the unit before its expiry date even if the device has not recorded any discharges. Respond to the self-test low-battery warnings with a new verified unit.
Accessories: also check the condition and expiry date of the Lifeline VIEW defibrillation electrodes to keep the device fully operational.
Other Defibtech batteries at Cahnos: DSA-DEA 7-year / 300-shock battery (ref. 88888931) and DSA-DEA 5-year / 125-shock battery, ref. DBP-1400 (ref. 88888845), both 15 V and exclusive to other models: they are not interchangeable with this reference.
Recycling: dispose of the exhausted battery at the authorised WEEE collection points in accordance with current regulations. For volume orders or tenders, contact the technical department at Cahnos stating the model, serial number and reference of the installed battery; we will confirm compatibility before finalising the order.