Description
1. Reliable power for your operating table
The EXA12-12 battery is the replacement power supply recommended for surgical tables and supporting medical accessories that work with sealed 12 V lead-acid cells. Its SLA chemistry guarantees a stable, leak-free supply, with the autonomy needed to keep the table operational during a power cut and complete patient positioning with total safety. It is a rechargeable, maintenance-free replacement that is easy to install, restoring the equipment to full operability in a few minutes. Ref. Cahnos 88889537; price per unit.
2. How this battery works
The EXA12-12 uses sealed valve-regulated lead-acid (VRLA) chemistry, making it leak-proof, rechargeable and suitable for medical equipment. It supplies a nominal voltage of 12 V with a capacity of 12 Ah, sufficient to power the control electronics, actuators and table positioning systems during clinical activity, as well as other auxiliary medical devices. Its sealed construction allows spill-free installation and its format corresponds to the standard market 12 V / 12 Ah cell, compatible with the usual battery compartment of these tables, reusing the original wiring. Like any VRLA cell, it offers a typical design life of 3 to 5 years under nominal use and charging conditions, with excellent recovery after moderate discharges.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Battery type | Sealed lead-acid (SLA) |
| Voltage | 12 V |
| Capacity | 12 Ah |
| Application | Surgical tables, auxiliary medical devices |
| Duration | Long-lasting and consistent performance |
| Reference | 88889537 |
| Installation | Easy installation and replacement |
| Chemistry / construction | Valve-regulated lead-acid (VRLA), sealed, leak-free and maintenance-free |
| Rechargeable | Yes; it recharges with the equipment charger |
| Maintenance | Maintenance-free |
| Standard market cell format | 12 V / 12 Ah (NP12-12 format base; typical dimensions 151 × 98 × 97.5 mm) |
| Presentation | Unit |
Note: the cell format indicated is the market standard to which this reference belongs and must be verified against the compartment of the specific table (height dimension, terminal type and polarity orientation).
4. Equivalences and Cross-References
The EXA12-12 conforms to the standard sealed lead-acid cell format 12 V / 12 Ah (reference cell format Yuasa NP12-12). The references from other manufacturers listed below belong to this same product category (12 V and 12 Ah VRLA/AGM battery), have been verified against official manufacturer data sheets and are classified as comparable by category, not 1:1 interchangeable: before replacement, the terminal type, dimensions, chemistry and polarity must be verified against the compartment of the specific table.
| Manufacturer / Brand | Family / Model | Code / reference | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| GS Yuasa | NP series (VRLA) | NP12-12 / NP12-12-250FR | Comparable by category (not interchangeable 1:1) | 12 V / 12 Ah, Faston F2 terminals (6.35 mm / 0.250 inches), 151 × 98 × 97.5 mm, ≈3.5 kg. Confirmed in the manufacturer’s official data sheet; verify height dimension and terminal type against the equipment. |
| Power-Sonic | PS series (AGM, general purpose) | PS-12120 (F2) | Comparable by category (not interchangeable 1:1) | 12 V / 12 Ah AGM with F2 terminals and dimensions 151 × 98 × 95 mm, ≈3.24 kg. Confirmed in the manufacturer’s official data sheet; height slightly lower than the reference cell, verify compartment and terminal orientation. |
| CSB Battery | GP series (AGM) | GP12120 | Comparable by category (not interchangeable 1:1) | 12 V / 12 Ah AGM, 151 × 97 × 94 mm, ≈3.67 kg, up to 5 years in standby service. Confirmed in CSB official data sheet; verify height dimension and F2 terminal of the batch. |
| Panasonic | LC-RA Series (AGM) | LC-RA1212P / LC-RA1212PG1 | Comparable by category (not interchangeable 1:1) | 12 V / 12 Ah, 151 × 94 × 98 mm, blade terminal 6.35 mm, ≈3.8 kg. Confirmed in the manufacturer’s data sheet and authorised distribution; verify height dimension and weight of the batch. |
There is no equivalence table validated by the manufacturer that authorises third-party batteries; consult the technical department before use in tenders. Before replacement, the following must be verified one by one: voltage (12 V), capacity (12 Ah), chemistry (sealed lead-acid), terminal type (Faston F1 or F2 depending on the equipment) and compartment dimensions (standard 12 V 12 Ah cell format).
5. Selection tips and variants of interest
Identify the exact model of the table: this 12 V / 12 Ah battery covers medium support equipment and auxiliary devices; always confirm the compartment, terminal type (Faston) and polarity orientation before mounting. Do not replace it with cells of a different voltage or with integrated wiring without prior technical validation.
Prevention and maintenance: VRLA cells self-discharge slowly at rest; if the table is to remain off for long periods, recharge it periodically to prevent the voltage from dropping below the recovery threshold (≈10.5 V). Replace the battery when the autonomy is noticeably reduced or the equipment warns of low battery.
Variants of the same family at Cahnos: EXA7-12 battery 12 V / 7 Ah in AGM (ref. 33192173), EXAG7-12 12 V / 7 Ah in gel (ref. 88889675), EXAG12-12 12 V / 12 Ah in gel (ref. 33192139), EXAG17-12 12 V / 17 Ah (ref. 88889674) and EXA18-12 12 V / 18 Ah (ref. 88889541). Do not interchange these references between models: each table accepts a specific voltage and capacity.
For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and a formalised quotation.





Reviews