Description
Standard paediatric defibrillator electrode with internal cable
This paediatric multifunction electrode is designed to ensure reliable resuscitation and monitoring in infant patients during critical environments. Its Snap connection allows direct attachment to the defibrillation cable if the defibrillator incorporates it, making it an essential replacement to keep Marquette GE and Esaote equipment operational in emergency departments, ambulances and intensive care units.
Technical explanation
It is a disposable multifunction electrode (patch) indicated for transthoracic external defibrillation, synchronized cardioversion, ECG monitoring and temporary non-invasive transcutaneous cardiac pacing. The standard paediatric model does not include an external cable: contact is made via a safety Snap-type (clip) connector on the equipment’s internal cable, in this case the GE Medical Systems cable ref. 22338301. Its low-impedance conductive adhesive gel and medical foam backing ensure optimal adaptation to the infant chest, with a reduced active area to concentrate energy without risk of burns in patients under 8 years of age or 25 kg in weight.
Technical specifications
| Brand / Compatible equipment | Marquette GE (1250 and 1500 First Responder, Responder 2000, Responder 3000) and Esaote (MDF, MDF Plus) |
| Connection type | Snap (press stud) – anti-shock safety connector |
| Compatible cable reference | GE Medical Systems cable ref. 22338301 |
| Application | Paediatric defibrillator – patient under 8 years (less than 25 kg) |
| Total area (each electrode) | 75 cm² |
| Active area (each electrode) | 40 cm² |
| Supported shocks | 50 shocks at 100 J |
| Gel | Low-impedance conductive adhesive |
| Conductive material | Metal foil |
| Backing material | 1 mm thick medical foam |
| ECG Monitoring | Up to 24 hours |
| Use | Single-use, disposable, non-sterile |
| Presentation | Box of 5 pairs (individual heat-sealed packaging per pair) |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Regulatory standard | ANSI/AAMI DF-80; IEC/EN 60601-1; IEC/EN 60601-2-4; ISO 10993-10 |
| Latex / Phthalates | Latex-free and phthalate-free |
| Shelf life | 30 months from the date of manufacture |
Equivalences and cross-references
The reference 22338301 corresponds to the original GE Medical Systems connection cable (internal cable of the defibrillator), not to the patch itself: this electrode is supplied without an external cable and attaches to that cable via a Snap connection. The functional category equivalence lies in the standard paediatric multifunction electrodes from GE Healthcare (Marquette) and Esaote (MDF/MDF Plus), as well as in the homologous families of other manufacturers in the sector (Schiller FRED/Defigard, Philips CodeMaster/HeartStart, Zoll, Physio-Control LIFEPAK) which, although they share clinical indication, are not interchangeable 1:1 because they differ in the connector and in the geometry of the contact.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
Selection tips and variants of interest
Always check the Snap connector and the cable of your equipment (GE Medical Systems ref. 22338301) before replacement; on Esaote equipment confirm the exact model (MDF or MDF Plus). For fleets with other equipment of the same family, in our catalogue you will find the variants F7962P (Marquette GE, Esaote) and F7981P (GE Responder and CardioServ type). Remember to limit energy to paediatric levels (up to 100 J), replace the electrode after 24 hours if it remains applied and do not reuse the product.