Description
1. Commercial Introduction
Keep your Agilent-Philips defibrillator always ready for emergencies with these compatible, disposable adult defibrillation electrodes (ref. GM33576), the ideal replacement consumable for emergency departments, critical care units, ambulances and cardioprotected areas equipped with devices from the Heartstream and HeartStart families. A single reference covers the main defibrillator-monitors of this platform —HeartStart XL, XLT and HeartStart 4000 with Philips M3508A cable—, simplifying the stock of resuscitation consumables. BSI-certified for adult patients, they are supplied in a kit of 2 units: contact our technical-commercial team. For large orders you can request a quote.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and enables emergency electrocardiographic monitoring. This adult pair is indicated for patients over 8 years of age or weighing more than 25 kg and is manufactured with a conductive adhesive gel that ensures excellent adhesion to the skin and adequate thickness, guaranteeing low interface impedance and optimal energy transmission during care. The set includes a pair of electrodes, the connection cable and the platform-specific connector (Philips M3508A cable). They are single-use and disposable: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging. The recommended placement is anterolateral (sternum-apex), following the anatomical diagrams on the multilingual pouch.
3. Technical specifications and tables
3.1 Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Kit of 2 units |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | C020401 |
| GMDN | 47055 |
| EAN | 8033003260319 |
3.2 Available references
| Reference | Model | Sales unit |
|---|---|---|
| GM33576 | Compatible electrodes for Agilent-Philips defibrillator (see also 55020) | Kit of 2 units |
| GM55020 | Compatible electrodes for Agilent-Philips defibrillator (manufacturer’s associated presentation) | Multipair |
3.3 Main features
| Parameter | Specification |
|---|---|
| Indicated population | Adults: patients >8 years (25 kg) |
| Use | Disposable, single-use |
| Kit contents | Pair of electrodes, cable and connector |
| Connection cable | Philips M3508A |
| Adhesion and gel | Excellent adhesion and adequate gel thickness |
| Material | Latex-free |
| Maximum shelf life | 30 months from the date of production (24 months in ref. 33584) |
| Certifications | BSI; ANSI/AAMI: DF-80; IEC/EN: 60601-1, 60601-2-4; ISO: 10993-1 |
| Conformity | Directive 93/42/EEC and amendments (Class IIb) |
| Packaging | Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU |
| Manufacture | Made in Italy |
3.4 Compatibility with defibrillators
| Equipment brand | Compatible models |
|---|---|
| Agilent-Philips | Heartstream/HeartStart XL M4735A (with Philips M3508A cable) |
| Agilent-Philips | Heartstream/HeartStart XLT M3500B (with Philips M3508A cable) |
| Agilent-Philips | HeartStart XL 861290 (with Philips M3508A cable) |
| Agilent-Philips | HeartStart 4000 M5500B (with Philips M3508A cable) |
Additional compatibility verified in the manufacturer’s catalogue: Philips Laerdal Medical Heartstream Fore Runner I AED defibrillators (models E, S, EM); HeartStart FR1 AED 940010XX, 940020XX and 940030XX; HeartStart FR2 AED M3841A and M3861A; HeartStart FR2+ AED with ECG module M3840A and M3860A; CodeMaster M1722A/B, M1723A/B, M1724A and M2475B (with Philips M3507A cable and 05-200 paddle adapter); and HeartStart MRx M3535A (with Philips M3508A cable).
4. Equivalences and Cross-References
This kit is a consumable compatible with the aforementioned Agilent-Philips defibrillators, not an original replacement certified by Philips: the connector, analysis algorithm and energy management are proprietary to each platform. The manufacturer’s catalogue associates this electrode with reference 55020 (multipair presentation of the same product) and with the master defibrillator model M1722A/B (CodeMaster). Within the range of compatible defibrillation electrodes, each platform requires its specific reference due to the proprietary connector: GM33575 (Nihon Kohden), GM33577 (Agilent Hewlett-Packard / Laerdal, with M3507A cable), GM33578 (Defibtech Lifeline) and GM33579 (Drager, Innomed, S&W, Welch Allyn). There is no manufacturer-validated equivalence table cross-referencing this reference with original Philips electrodes: always verify the exact device model and connector fit before clinical use.
5. Selection tips and variants of interest
Confirm the device model: check on the defibrillator plate that your model is among the compatible ones (HeartStart XL M4735A, XLT M3500B, HeartStart XL 861290, HeartStart 4000 M5500B or the manufacturer’s additional models) and that the Philips M3508A cable fits correctly into the electrode socket before clinical use. Presentation and volume: reference GM33576 is supplied in a kit of 2 units for individual replacement; if your facility manages several devices or high turnover, consult the associated multipair presentation (reference 55020). Adult use: these electrodes are indicated for patients over 8 years of age or over 25 kg; for paediatric care consider the specific paediatric electrode variants of the same family. Expiry and storage: maximum shelf life of 30 months from the date of production; store in a dry place and respect the expiry date on the packaging, as the gel may lose conductivity if exceeded. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock by expiry date (FIFO method). For volume orders or tenders, contact the technical-commercial department of Cahnos indicating the exact models of your devices.