Preconnected Paediatric Defibrillation Electrodes for OB Life Support 300 Defibrillator (Ref. F7956P / BRLF7956P)

85,14 €

The manufacturer’s preconnected paediatric defibrillation electrodes, specifically designed for the care of children with the OB Life Support 300 defibrillator. They connect instantly, with no prior steps or assembly time, a critical aspect in a paediatric cardiac arrest. They feature a yellow connector and are indicated for paediatric patients weighing less than 25 kg (under 8 years), ensuring the appropriate energy and safe placement on the child’s chest. Essential replacement consumable for emergency units, ambulances, health centres and BLS/AED equipment with this unit. References: F7956P (manufacturer) and BRLF7956P (SKU Cahnos). Distributed by Cahnos, consult our technical-commercial team. For large orders you can request a quote.

In stock

International shipping. Import duties and taxes are payable by the recipient.

Reference
BRLF7956P

Description

1. Commercial Introduction

The preconnected paediatric defibrillation electrodes are the reference consumable for providing paediatric capability to the manufacturer’s OB Life Support 300 defibrillator. Designed for emergency and urgent care services, ambulances, medicalised units, health centres and civil protection services, they allow rapid and fully safe management of cardiac arrest in paediatric patients. As they come preconnected, they eliminate any connection step at the critical moment: open, place and defibrillate. Distributed by Cahnos in Spain: For large orders you can request a quote. Consult our technical-commercial team for supply conditions, lead times and volumes.

2. Technical explanation of the equipment

In paediatric defibrillation, speed of preparation and correct energy selection are decisive for the prognosis. These electrodes are supplied already connected to the equipment wiring, so the rescuer only needs to remove the protective cover, place the pads on the child’s chest and deliver the shock according to protocol. The manufacturer states that electrodes with the yellow connector should be used in children weighing less than 25 kg (under 8 years), a criterion that avoids excessive energy on the paediatric myocardium. The design is optimised for the paediatric chest surface, ensuring good contact, low impedance and effective shock distribution, as well as quick and clean removal after use.

3. Technical Specifications

3.1. Product data

Product Preconnected paediatric defibrillation electrodes
Manufacturer Boscarol
Manufacturer reference F7956P
SKU Cahnos BRLF7956P
Connection type Preconnected
Connector Yellow
Compatibility Defibrillator OB Life Support 300
Target population Children weighing less than 25 kg (under 8 years)
Application Paediatric defibrillation in emergency, urgent care and transfers

3.2. Key features

  • Paediatric electrodes preconnected: ready to use at the critical moment.
  • Compatible with the OB Life Support 300 defibrillator.
  • Yellow connector for immediate identification of the paediatric version.
  • Indicated for patients weighing less than 25 kg (under 8 years).
  • Official replacement consumable of the advanced life support range.

3.3. Available references

Manufacturer reference SKU Cahnos Description
F7956P BRLF7956P Preconnected paediatric defibrillation electrodes for OB Life Support 300 (this product)

4. Equivalences and Cross-References

This product corresponds to the manufacturer’s original reference F7956P, marketed by Cahnos under the code BRLF7956P (same product, dual numbering, no additional variants). There is no verified 1:1 equivalence table with specific codes from other manufacturers: defibrillation pads and electrodes are specific to each brand and each equipment model, so they must not be replaced with consumables from other brands without prior technical validation. For tenders, fleet comparisons or verification of compatibility with your exact equipment model, consult the technical-commercial department of Cahnos.

5. Selection tips and variants of interest

Always verify compatibility with your equipment: these electrodes are indicated exclusively for the OB Life Support 300 defibrillator. Confirm that your equipment includes the paediatric version (yellow connector) in addition to the adult one, since the selection criterion is the patient’s weight (<25 kg / under 8 years) and not age alone. Periodically check the expiry date and the integrity of the electrode seal, and rotate the stock in the ambulance to ensure they are always operational. For volume purchases, supply agreements or the complete equipment of your emergency service, contact the technical-commercial team of Cahnos.

Additional information

Manufacturer

Oscar Boscarol S.r.l.

Manufacturer reference

F7956P

Product type

Preconnected paediatric defibrillation electrodes

Compatibility

Defibrillator OB Life Support 300

Connection type

Preconnected

Connector colour

Yellow

Target population

Children weighing less than 25 kg (under 8 years)

Application

Paediatric defibrillation in emergency and urgent care

Presentation

Pair of electrodes

Documentation