Description
1. Introduction
The Amnioquick Test in test strips is the professional solution for quickly and reliably confirming rupture of the amniotic sac in pregnant women with suspected leakage of amniotic fluid. Designed for obstetrics departments, hospital emergency units, delivery rooms and gynaecology clinics, this test enables a rapid response to one of the most common complications of pregnancy (premature rupture of membranes affects 5–10% of pregnancies). Practical test strip format in a box of 10 units, ready to use without specialised equipment and with visual reading within minutes.
2. Technical explanation of the procedure
The test is based on a lateral flow chromatographic immunoassay that qualitatively detects the protein IGFBP-1 (insulin-like growth factor-binding protein type 1), present in high concentration in amniotic fluid and virtually absent from normal vaginal secretions. The sample is collected with the included sterile vaginal swab, introduced into the single-dose dropper vial with solvent, and the test strip is immersed with the arrows pointing downwards. If the sample contains IGFBP-1, a purple line appears in the test zone (T); the control line (C) validates the correct development of the assay. The result is read at 10 minutes and must not be interpreted after 15 minutes. The assay cut-off is set at 5 ng/ml of IGFBP-1, allowing detection of less than 1 microlitre of amniotic fluid in vaginal secretions, limiting interference from semen, urine or blood. Each strip is single-use.
3. Technical Specifications
The general product features, the contents of each pack and the technical data of the assay are detailed below.
General characteristics
| Parameter | Specification |
|---|---|
| Product | Rapid test for detection of amniotic sac rupture (Amnioquick type) |
| Format | Test strips (dipstick) |
| Presentation | Box with 10 units (10 individual packages) |
| Reference | 431006N-20 |
| Function | Rapid identification of amniotic fluid |
| Application | Professional use in clinical and obstetric settings |
Technical data of the assay
| Parameter | Specification |
|---|---|
| Assay principle | Lateral flow immunochromatography, qualitative, with anti-IGFBP-1 monoclonal antibodies |
| Marker detected | IGFBP-1 (insulin-like growth factor-binding protein type 1) |
| Sample type | Vaginal secretion collected with sterile swab |
| Contents of each package | 1 test strip · 1 sterile vaginal swab · 1 single-dose dropper vial of solvent · 1 patient sheet (instructions and results record) |
| Time to result | 10 minutes (do not interpret after 15 minutes) |
| Limit of detection | Cut-off of 5 ng/ml of IGFBP-1; detects less than 1 µl of amniotic fluid |
| Reading and interpretation | Positive: C and T lines · Negative: only C line · Invalid: absence of C line |
| Storage | 2–30 °C, in a dry place and protected from moisture |
| Stability | 18 months from the date of manufacture |
| Use | Professional, single-use · in vitro diagnostic (IVD) · CE marked |
Clinical performance of the detection principle
According to the clinical studies referred to in the instructions for use of Amnioquick-type technology (IGFBP-1 detection), relative sensitivity ranges from 80% to 98.48% and specificity from 93.1% to 100%, depending on the hospital centre and sample size. These values correspond to the IGFBP-1 detection principle validated by the reference manufacturer of the technology; please request the specific clinical data for the supplied batch from the technical department.
4. Equivalences and Cross-References
The reference 431006N-20 is a Cahnos distribution code for an Amnioquick-type test; it must not be confused with the official numbering of the manufacturer of the reference technology (BIOSYNEX, ref. 1090003). The products verified in official sources (manufacturer’s website and IFU) that share clinical indication and, where applicable, technology are listed below:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| BIOSYNEX (France) | AMNIOQUICK® (test strips) | 1090003 (10 tests) · 1090003-25 (25 tests) | Comparable by category (not interchangeable 1:1) | Same technology (IGFBP-1, strip format, reading at 10 min) and same presentation of 10 tests. Verified on BIOSYNEX’s official website and IFU. As these are different distributor codes, confirm approval before substituting. |
| Actim / Medix Biochemica (Abbott Point of Care) | Actim® PROM | 30831ETAC (10 tests) · 30832ETAC (20 tests) | Comparable by category (not interchangeable 1:1) | Detects IGFBP-1 in dipstick format with result in 5 minutes; tolerant to blood, semen, urine and vaginal infections. Verified on official website. |
| QIAGEN | AmniSure® ROM Test | FMRT-1-10-US (10 tests) · FMRT-1-25-US / FMRT-1-25-ML-RT (25 tests) | Comparable by category (not interchangeable 1:1) | Detects PAMG-1 (a marker different from IGFBP-1) in strip format, reading at 10 minutes, sensitivity of 99% and specificity of 98%. Verified on official website. |
| Pro-Lab Diagnostics | AmnioTest™ (nitrazine swab) | PL.901 | Comparable by category (not interchangeable 1:1) | Screening by elevation of vaginal pH (nitrazine yellow); rapid and economical, but less specific than immunochromatographic tests. Verified on official website. |
There is no equivalence table validated by the manufacturer that cross-references 1:1 the reference 431006N-20 with other brands; consult the technical department before using in tenders.
5. Selection tips and variants of interest
For services with a frequent patient volume, consider the presentation of 25 tests per box or the cassette format, which isolates the migration zone from the sample deposition zone and reduces the risk of external contamination. If your protocol requires confirmation with a second marker, there are combined variants that detect IGFBP-1 together with alpha-fetoprotein (AFP). In pregnancies with vaginal bleeding associated with suspected rupture, the blood-tolerant IGFBP-1-based test (Actim PROM type) is the recommended alternative; for confirmation with the specific PAMG-1 marker, the AmniSure test can be used, and for rapid low-cost screening, nitrazine swabs (less specific). In the Cahnos catalogue we also have the rapid iGFBP-1 test in cassette of 25 units (Ref. FIG-502) and the amniotic sac rupture test Ref. 0042017. It is recommended to perform the test within 12 hours of fluid loss (beyond this time false negatives increase), respect the 10-minute reading time, do not interpret the strip after 15 minutes, and store the kit between 2 and 30 °C, in a cool, dry place, until use. For volume quotations, technical documentation or presentation variants, contact our commercial department.