Description
1. Commercial Introduction
The STREP-A TEST two-colour strip (reference 24519) is an in vitro diagnostic device for professional use designed for the diagnostic orientation of sore throats of possible bacterial origin at the point of care: general medicine and paediatric consultations, emergency departments, community pharmacy and primary care. With a simple throat sample obtained with a swab, it allows you to know within a few minutes whether the origin of the infection is Streptococcus pyogenes (group A beta-haemolytic streptococcus), facilitating the clinical decision of whether or not to start antibiotic treatment and helping to avoid unnecessary use of antibiotics.
It is presented in a professional box of 50 determinations with all the materials needed to perform the tests, without requiring any additional equipment. The two-colour technology offers a more comfortable and reliable reading, ideal for high-volume testing environments.
2. Technical explanation of the procedure
The device uses an optical lateral flow immunoassay with coloured particles labelled with antibodies, deposited in two separate locations on the device. The sample collected with the sterile swab is processed in the tube with the extraction reagents; the extracted solution migrates by capillary action through the reactive membrane and, if it contains group A streptococcus antigen, a red test line (T) is generated indicating a positive result. In parallel, a blue control line (C) confirms the validity of the assay at all times.
The two-colour system combines higher sensitivity and a lower risk of false negatives without compromising specificity, maintaining the standard procedure and a simple visual reading in approximately 5 minutes: if the sample contains the antigen, both lines appear (red T and blue C), while only the blue control line indicates a valid negative result. The kit includes 50 strips, 50 tubes, 50 swabs, 2 reagents and 2 control solutions.
3. Technical specifications and tables
Technical specifications
| Parameter | Value |
|---|---|
| Relative sensitivity | 95.1% (95% CI: 89.6-98.2%) |
| Relative specificity | 97.8% (95% CI: 95.8-99%) |
| Overall accuracy | 97.1% (95% CI: 95.3-98.4%) |
Product data
| Field | Value |
|---|---|
| Sales unit | Box of 50 units (box of 50 pcs) |
| Device type | IVD – Professional use |
| CND | W0105090103 |
| EAN | 8023279245196 |
| Manufacturer | GIMA |
| Manufacturer reference | 24519 |
Kit contents
50 test strips, 50 extraction tubes, 50 swabs, 2 reagents and 2 control solutions.
Expiry notice: the tests have a short expiry date. Most tests have 24 months of shelf life at the time of production; stock may vary between 10 and 22 months. Check the expiry date when confirming your order.
4. Equivalences and Cross-References
This product corresponds to reference 24519 (SKU Cahnos GM24519), the two-colour strip variant of the STREP-A TEST family, which shares the clinical indication, lateral flow immunochromatography technology and 5-minute reading time with the rest of the range for detection of group A streptococcus in pharyngeal exudate.
| Reference | Format | Sales unit |
|---|---|---|
| GM24521 | Strip | Box of 25 units |
| GM24520 | Cassette (device) | Box of 20 units |
| GM24619 | Cassette for immunofluorescence analyser Ref. 24600 | Box of 10 units |
In the Cahnos catalogue, reference IST-N502 (Rapid Strep A Sore Throat Test, AllTest/ACRO Biotech) shares the clinical indication and 5-minute reading time with very similar technology and format, as well as the technical data sheets SPINREACT A0159 or the formats distributed by Akralab/Akratest present in the European market; however, it is advisable to validate the centre’s internal approval before replacing one device with another.
5. Selection tips and variants of interest
- Professional use: indicated for community pharmacy, medical practices, paediatrics, emergency departments and clinical laboratories. It should be used as a diagnostic aid together with the clinical assessment of the patient.
- Format selection: this two-colour strip variant (box of 50) is the most economical option per determination and has a simple visual reading, indicated for medium-to-high volume centres. If you prefer the cassette format with a well, see reference GM24520 (box of 20).
- Sample collection: perform the pharyngeal swabbing on the posterior pharynx and the tonsils, avoiding the tongue and bleeding areas, to maximise antigen concentration and avoid interference.
- Result confirmation: with positive results, the therapeutic decision can be initiated quickly; negative or doubtful results must be confirmed by microbiological culture.
- Storage: keep the devices in their sealed packaging, protected from moisture and direct sunlight, and respect the expiry date indicated on the packaging.
- Stock management: as this is a product with a short shelf life, plan your orders with our technical-sales team to ensure proper inventory turnover. For large orders you can request a quote.