170,05 €

Portable haemoglobin (Hb) and haematocrit (Hct) analyser MISSION® Hb, designed for professional use in practices, laboratories and health centres. It determines Hb and Hct in less than 15 seconds from just 10 µL of capillary or venous whole blood, without prior sample preparation and with automatic calibration via code chip. It offers a wide Hb measurement range of 4.5 to 25.6 g/dL and Hct from 13 to 75%, with accuracy comparable to automatic haematology analysers and memory of up to 1,000 results with date, time and ID. Professional-use IVD product, operates on AAA batteries, and includes strips, lancets, capillary tubes, lancet holder and carrying case. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM24022

Description

1. Commercial Introduction

The MISSION® Hb haemoglobin and haematocrit analysis system is the ideal point-of-care diagnostic solution for medical practices, health centres, clinical laboratories and emergency services that need a reliable Hb and Hct result immediately. Its compact and portable design allows testing at the patient’s side with just 10 µL of blood and a reading in less than 15 seconds, without requiring sample preparation. A professional tool that streamlines anaemia screening, preoperative assessment and patient follow-up, maintaining a level of accuracy comparable to that of automatic haematology analysers.

2. Technical explanation of the equipment

The MISSION® Hb meter uses the principle of methemoglobin detection by reflectance photometry at a wavelength of 525 nm. When the test strip is inserted and the sample is introduced, the device measures the reflectance generated by the reaction and converts the result into quantitative haemoglobin (Hb) and haematocrit (Hct) values in less than 15 seconds. The system incorporates automatic calibration via code chip, so it does not require specimen preparation or manual calibration. It works with capillary or venous whole blood (only 10 µL), stores up to 1,000 results with date, time and patient identification, and offers auto power-off after 8 minutes to optimise the consumption of the 3 AAA batteries (up to 2,700 tests or 360 hours of use). The use of dry test strips eliminates the drawbacks of transporting and storing liquid reagents.

3. Technical Specifications

The complete technical specifications of the MISSION® Hb system are detailed below:

3.1. Measurement characteristics

Methodology Reflectance photometry
Detection principle Methemoglobin
Time to result < 15 seconds
Sample type and volume 10 µL / capillary and venous whole blood
Hb measurement range 4.5 – 25.6 g/dL
Hct range 13 – 75%
Wavelength 525 nm
Calibration Automatic
Precision CV (intra-series) Hb = 3%
Precision CV total Hb = 3%
Accuracy Hb 4.5 – 10 g/dL, ±0.4 g/dL; Hb 10 – 25.6 g/dL ± 4%
Memory 1,000 tests with date/time and ID number

3.2. Power supply and dimensions

Power supply 3 AAA batteries or AC adapter on request
Battery life 2,700 tests or 360 hours
Auto power-off 8 minutes
Size (LxWxH) 127 x 58 x 25 mm

3.3. Included accessories

  • 10 test strips
  • 1 code chip
  • 3 AAA batteries
  • 10 lancets (26 G)
  • 2 control strips
  • 1 carrying case
  • 1 lancet holder
  • 10 capillary transfer tubes (plastic)
  • User manual in English and Italian

Multilingual box presentation: GB, FR, IT, ES, PT, DE, PL, RO, SE, FI, GR, TR, Arabic. Mini USB output for PC connection.

3.4. Product data

Brand MISSION
Sales unit 1 piece
Device type IVD – Professional use
CND W02020699
EAN 0682607610327
Manufacturer reference 24022
SKU Cahnos GM24022
Available references 24022

4. Equivalences and Cross-References

The reference 24022 (SKU Cahnos GM24022) corresponds to the manufacturer’s official factory code within the MISSION® range of portable analysers, dedicated to quantitative in vitro diagnostic (IVD) tests. Within the same MISSION® ecosystem there are other analysers in the brand family, such as the cholesterol meter with 3-in-1 lipid panel (reference 23932) and the MISSION® thermal printer (reference 23929), compatible with the point-of-care diagnostic workflow. There is no manufacturer-validated cross-reference table that would allow this system to be exchanged 1:1 with haemoglobin meters from other manufacturers; any comparison with third-party reflectance photometry equipment must be validated field by field (sample, volume, measurement range, precision and units) before use in tenders or stock replacement.

5. Selection tips and variants of interest

This system is marketed as a 1-piece sales unit (complete device with starter accessories). For continued use, it is recommended to plan for the consumption of test strips, control strips, lancets and capillary tubes, as well as the specific calibration code chip. It is a professional-use IVD device: intended for qualified healthcare personnel in laboratories, practices and care services that require rapid monitoring of Hb and Hct. Always verify that the test strips correspond to the MISSION® Hb range of the device, use the control strips to validate the batch and keep the meter with its 3 AAA batteries or AC adapter. For institutional volumes, multi-unit allocations or specific B2B supply conditions, contact the technical-commercial department of Cahnos.

Additional information

Manufacturer reference

24022

Manufacturer

GIMA S.p.A.

CND code

W02020699

EAN

0682607610327

Methodology

Reflectance photometry

Detection principle

Methemoglobin

Time to result

< 15 seconds

Sample type

Capillary and venous whole blood

Sample volume

10 µL

Hb range

4.5 – 25.6 g/dL

Hct range

13 – 75%

Wavelength

525 nm

Calibration

Automatic (code chip)

Precision CV intra-series Hb

= 3%

Precision CV total Hb

= 3%

Accuracy

Hb 4.5 – 10 g/dL, ±0.4 g/dL; Hb 10 – 25.6 g/dL ± 4%

Memory

1,000 results with date/time and ID

Power supply

3 AAA batteries or AC adapter (on request)

Battery life

2,700 tests or 360 hours

Auto power-off

8 minutes

Measurements

127 x 58 x 25 mm

Connection

Mini USB output

Included accessories

Test strips, code chip, AAA batteries, 26G lancets, control strips, carrying case, lancet holder, capillary tubes and manual

Presentacion

Unit

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF
📜 CertificatesCertificati vari PDF

Reviews

There are no reviews yet.

Be the first to review “MISSION® Hb Haemoglobin and Haematocrit Analysis System – Portable Professional-Use Meter by Reflectance Photometry | Ref. 24022”

Your email address will not be published. Required fields are marked *