We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Glucose Monitor Blood Glucose Meter Kit mg/dL | Ref. 24110 | Blood Glucose Self-Monitoring Kit (GB, FR, IT, ES, PT, DE)

30,40 €

Complete Glucose Monitor blood glucose meter kit in mg/dL (ref. 24110), a blood glucose self-monitoring system from the manufacturer for patient and professional use in pharmacies, clinics and health centres. It incorporates an electrochemical biosensor with GDH-FAD technology (developed by Acon), results in just 5 seconds with a micro-sample of 0.6 µL and plasma-equivalent calibration without coding. Valid for capillary, venous and neonatal blood, with testing on the fingertip, forearm or palm, and memory for 1,000 results with averages for 7, 14, 30, 60 and 90 days. The kit includes 10 test strips, control solution, 10 sterile lancets, lancing device, transparent cap for alternative site testing, carrying case and multilingual manual (Spanish included). Complies with ISO 15197:2013 / EN ISO 15197:2015. IVD self-test device for B2B. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM24110

Description

1. Commercial Introduction

The Glucose Monitor blood glucose meter kit in mg/dL (ref. 24110) is the manufacturer’s blood glucose monitoring solution for patient self-monitoring and professional use in pharmacies, clinics and health centres. Presented in mg/dL, this meter combines clinical precision, simple handling and a compact design, suitable for both spot measurements at home and ongoing monitoring in the healthcare setting. The kit arrives complete, ready to start, with everything needed for the first measurements, and includes a box and manual in six languages: English, French, Italian, Spanish, Portuguese and German.

2. Technical explanation of the equipment

The Glucose Monitor system, developed with Acon technology, uses an electrochemical biosensor with glucose dehydrogenase (GDH-FAD) enzyme that, on contact with a minimal whole blood sample (0.6 µL), generates a signal proportional to the glucose concentration, with plasma-equivalent calibration and no strip coding required. The result is obtained in just 5 seconds and is valid for capillary, venous and neonatal blood; it allows testing on the fingertip, forearm or palm and tolerates a haematocrit range of 10 to 70%. The device stores up to 1,000 results with date and time, calculates averages for 7, 14, 30, 60 and 90 days and incorporates automatic detection of insufficient sample, acceptance of a second sample application and detection of sample disturbance. The system complies with the standards ISO 15197:2013 / EN ISO 15197:2015.

3. Technical Specifications

Parameter Value
Technology Biosensor / Electrochemical, Glucose dehydrogenase (GDH-FAD)
Calibration method No coding
Result calibration Plasma equivalent
Test time 5 seconds
Sample volume 0.6 µL
Sample type Fresh whole blood (capillary, venous, neonatal)
Test sites Fingertip, forearm, palm
Haematocrit range 10-70 %
Memory 1,000 results with date and time
Averages 7, 14, 30, 60 and 90 days
Data transfer USB cable – optional
Control solution 3 levels
Auto power-off 2 minutes after the last action
Power supply 2 button cell batteries CR 2032 3.0 V
Battery life 3,000 measurements
Other functions Automatic detection of insufficient sample / accepts second sample application / detection of sample disturbance

Kit contents

Component Included
Glucose test strips 10 units
Control solution 1 bottle
Sterile lancets 10 units
Lancing device (lancet) 1 unit
Transparent cap (testing on forearm or palm) 1 unit
Carrying case 1 unit
User manual (box and multilingual manual: GB, FR, IT, ES, PT, DE) 1 unit

Product data

Manufacturer GIMA
Manufacturer reference 24110
SKU Cahnos GM24110
Sales unit 1 pc
Device type IVD – Self Test
CND W0101050205
EAN 8023279241105

4. Equivalences and Cross-References

The manufacturer’s reference is Ref. 24110 (SKU Cahnos GM24110), the standard version (without Bluetooth) of the Glucose Monitor system. The Bluetooth variant corresponds to reference 24114 (GM24114), with identical technical features plus wireless connectivity for data transmission. No direct equivalents with blood glucose meters from other manufacturers are indicated as they are not confirmed in reliable sources; the use of original consumables is recommended to ensure full accuracy and compatibility. The consumables and accessories for this system in the Cahnos catalogue are:

Reference Description
GM24110 Glucose Monitor blood glucose meter kit without Bluetooth (this product)
GM24114 Glucose Monitor blood glucose meter kit with Bluetooth
GM24118 Glucose test strips – box of 25 units
GM24119 Glucose test strips – box of 50 units
GM24120 Glucose test strips – box of 100 units
GM24121 Control solution for Glucose Monitor
GM35177 USB cable for PC connection (optional)

5. Selection tips and variants of interest

If you need to transmit results to management platforms or carry out remote patient monitoring, consider the Bluetooth version (ref. 24114, GM24114); if you only require spot blood glucose measurements, the standard version (24110) is sufficient. For system accuracy control, use the control solution from the range (GM24121) and replenish test strips according to usage volume: box of 25 (GM24118) to start, 50 (GM24119) or 100 (GM24120) units for ongoing use. The USB cable (GM35177) allows wired data download on PC-300 series devices. For large orders you can request a quote: contact the Cahnos sales team for B2B terms.

Additional information

Manufacturer reference

24110

EAN

8023279241105

CND code

W0101050205

Technology

Electrochemical biosensor, glucose dehydrogenase (GDH-FAD)

Calibration method

No coding

Result calibration

Plasma equivalent

Test time

5 seconds

Sample volume

0.6 µL

Sample type

Fresh whole blood (capillary, venous, neonatal)

Test sites

Fingertip, forearm, palm

Haematocrit range

10-70 %

Memory

1,000 results with date and time

Averages

7, 14, 30, 60 and 90 days

Data transfer

USB cable (optional)

Control solution

3 levels

Power supply

2 button cell batteries CR 2032 3.0 V

Battery life

3,000 measurements

Regulatory standard

ISO 15197:2013 / EN ISO 15197:2015

Contents

10 test strips, control solution, 10 sterile lancets, lancing device, transparent cap, carrying case, multi-user manual

Languages

GB, FR, IT, ES, PT, DE

Presentacion

Unit

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📄 Technical sheet / test reportScheda di sicurezza PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF
📜 CertificatesDichiarazioni Varie PDF

Reviews

There are no reviews yet.

Be the first to review “Glucose Monitor Blood Glucose Meter Kit mg/dL | Ref. 24110 | Blood Glucose Self-Monitoring Kit (GB, FR, IT, ES, PT, DE)”

Your email address will not be published. Required fields are marked *