Control solution for MISSION® 3-in-1 lipid profile analyser – Verification kit (Ref. 23936)

54,15 €

Original control solution (ref. 23936) to verify the correct operation of the MISSION® 3-in-1 lipid profile analyser (ref. 23932). This control liquid kit allows you to validate the accuracy of the system before each use, when opening a new pack of tests or when an erroneous result is suspected, ensuring reliable cholesterol, triglyceride and HDL determinations in clinics, pharmacies and health centres. In vitro diagnostic self-test device (IVD – Self Test) in a 1 kit presentation. B2B via Cahnos. For large orders you can request a quote.

Sales unit: 1 kit
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM23936

Description

1. Commercial Introduction

The control solution for the MISSION® 3-in-1 analyser (ref. 23936) is the essential complement for maintaining the reliability of your lipid profile analysis system. Developed by the manufacturer specifically for the MISSION® series analyser (ref. 23932), it allows you to quickly and easily check that the equipment and tests are working within the expected parameters. Ideal for clinics, pharmacies, health centres and laboratories that carry out cholesterol, triglyceride and HDL screenings at the point of care.

2. Technical Explanation

The control solution is a liquid with known concentrations of the analytes detected by the system, which is applied to the test in the same way as a capillary blood sample. The analyser reads the reaction and displays the result: if the value obtained falls within the range indicated on the container label, the system is validated and ready for use with patients; if it falls outside the range, it indicates that the equipment or tests require review.

Quality control is recommended periodically, when opening a new pack of tests, in the event of unexpected results, after a drop of the equipment or when deterioration of the consumables is suspected. It is an in vitro diagnostic product for self-testing (IVD – Self Test), indicated both for patient self-monitoring and for use in professional dispensing.

3. Technical Specifications

Manufacturer GIMA
Manufacturer reference 23936
Sales unit 1 kit
Device type IVD – Self Test
CND W0101050299
EAN 0682607611096
Compatibility MISSION® 3-in-1 lipid profile analyser (ref. 23932)
Function Quality control for the cholesterol, triglyceride and HDL analysis system
Presentation 1 kit

4. Equivalences and Cross-References

This product corresponds to the factory reference Ref. 23936 (SKU Cahnos GM23936) and is intended exclusively for the MISSION® 3-in-1 lipid profile analyser (ref. 23932). The same system includes the 3-in-1 lipid profile tests with 35 µL capillary tubes (ref. GM23933, box of 25 units) and their variant with safety lancets (ref. GM23935, box of 5 units), as well as the MISSION® thermal printer (ref. GM23929). No 1:1 equivalences validated by the manufacturer with control solutions from other brands have been found in reliable sources: the consumables of each platform are not interchangeable, so it is recommended to always use the original control solution to ensure compatibility and accuracy of results.

5. Selection tips and variants of interest

Confirm that your equipment is the MISSION® 3-in-1 lipid profile analyser (ref. 23932) before placing the order. Perform a quality control with this solution every time you open a new pack of tests, in the event of unexpected results or after a drop of the equipment: it is the fastest way to ensure reliable cholesterol, triglyceride and HDL determinations. Complete the system by replenishing the 3-in-1 tests according to usage volume (ref. GM23933 with 35 µL capillary tubes, or ref. GM23935 with safety lancets included) and, if you need printed documentation, the MISSION® thermal printer (ref. GM23929). For large orders you can request a quote: consult the Cahnos commercial team for B2B supply conditions.

Additional information

Manufacturer reference

23936

CND code

W0101050299

EAN

0682607611096

Compatibility

MISSION® 3-in-1 lipid profile analyser (ref. 23932)

Presentacion

Kit

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Control solution for MISSION® 3-in-1 lipid profile analyser – Verification kit (Ref. 23936)”

Your email address will not be published. Required fields are marked *