Blood glucose meter Glucose Monitor Kit mg/dL with Bluetooth | Ref. 24114 | Blood Glucose Self-Monitoring Kit

41,80 €

Glucose Monitor blood glucose self-monitoring kit in mg/dL with Bluetooth (ref. 24114), an electrochemical biosensor blood glucose meter with GDH-FAD technology, fast (5 seconds), with a minimum sample of 0.6 µL and memory for 1,000 results. Valid for capillary, venous and neonatal blood, with testing on the fingertip, forearm or palm. Includes 10 strips, control solution, 10 sterile lancets, lancet, transparent cap, case and manual in several languages (ES included). Complies with ISO 15197:2013 / EN ISO 15197:2015. Its integrated Bluetooth allows data transmission to management platforms for professional patient monitoring. IVD self-test device for B2B. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM24114

Description

Blood glucose meter Glucose Monitor Kit mg/dL with Bluetooth

The Glucose Monitor blood glucose meter kit with Bluetooth (ref. 24114) is the manufacturer’s blood glucose monitoring solution for patient self-monitoring and professional use in pharmacies, surgeries and health centres. Presented in mg/dL, this meter combines clinical accuracy, simple handling and wireless connectivity to integrate readings into data management platforms. The kit arrives complete, ready to start, with everything needed for the first measurements.

Technical explanation of the equipment

The Glucose Monitor system, developed with Acon technology, uses an electrochemical biosensor with the enzyme glucose dehydrogenase (GDH-FAD) which, on contact with a minimal whole blood sample (0.6 µL), generates a signal proportional to the glucose concentration, with result calibration equivalent to plasma and no coding required. The result is obtained in just 5 seconds and is valid for capillary, venous and neonatal blood, allows testing on the fingertip, forearm or palm and tolerates a haematocrit range of 10 to 70%. The Bluetooth version incorporates fully integrated connectivity that allows results to be transmitted to data management platforms, facilitating continuous monitoring. The system complies with the ISO 15197:2013 / EN ISO 15197:2015 standards.

Technical specifications

Technology Biosensor/Electrochemical, Glucose dehydrogenase (GDH-FAD)
Calibration method No coding
Result calibration Plasma equivalent
Test time 5 seconds
Sample volume 0.6 µL
Sample type Fresh whole blood (capillary, venous, neonatal)
Test sites Fingertip, forearm, palm
Haematocrit range 10-70%
Memory 1,000 results with date and time
Averages 7, 14, 30, 60 and 90 days
Data transfer USB cable – optional
Control solution 3 levels
Auto power-off 2 minutes after the last action
Power supply 2 button cell batteries CR 2032 3.0 V
Battery life 3,000 measurements
Other functions Automatic detection of insufficient sample / supports second sample application / detection of sample disturbance

Kit contents

Component Included
Glucose test strips 10 units
Control solution 1 bottle
Sterile lancets 10 units
Lancing device (lancet) 1 unit
Transparent cap (testing on forearm or palm) 1 unit
Carrying case 1 unit
User manual (box and multilingual manual: GB, FR, IT, ES, PT, DE) 1 unit

Product data

Manufacturer GIMA
Manufacturer reference 24114
SKU Cahnos GM24114
Sales unit 1 pc
Device type IVD – Self Test
CND W0101050205
EAN 8023279241143

Equivalences and cross-references

The manufacturer’s reference is Ref. 24114 (SKU Cahnos GM24114), the Bluetooth version of the Glucose Monitor system. The non-Bluetooth variant corresponds to reference 24110 (GM24110), with identical technical specifications except for connectivity. The consumables and accessories for this system in the Cahnos catalogue are:

Reference Description
GM24114 Glucose Monitor blood glucose meter kit with Bluetooth (this product)
GM24110 Glucose Monitor blood glucose meter kit without Bluetooth
GM24118 Glucose test strips – box of 25 units
GM24119 Glucose test strips – box of 50 units
GM24120 Glucose test strips – box of 100 units
GM24121 Control solution for Gima Glucose Monitor
GM35177 USB cable for PC connection (optional)

No direct equivalences with blood glucose meters from other manufacturers are indicated as they have not been confirmed in reliable sources; the use of original consumables is recommended to guarantee complete accuracy and compatibility.

Selection tips and variants of interest

Choose the Bluetooth version (24114) if you need to transmit results to management platforms or carry out remote patient monitoring; if you only require occasional readings, the standard version (24110) is sufficient. For system accuracy control, use the control solution (GM24121) and replenish the test strips according to usage volume: box of 25 (GM24118) for start-up, 50 (GM24119) or 100 (GM24120) units for continuous use. The USB cable (GM35177) allows data download by cable on PC-300 series equipment. For large orders you can request a quote: contact the Cahnos commercial team for B2B conditions.

Additional information

Manufacturer reference

24114

Technology

Biosensor/Electrochemical, Glucose dehydrogenase (GDH-FAD)

Calibration method

No coding

Result calibration

Plasma equivalent

Test time

5 seconds

Sample volume

0.6 µL

Sample type

Fresh whole blood (capillary, venous, neonatal)

Test sites

Fingertip, forearm, palm

Haematocrit range

10-70%

Memory

1,000 results with date and time

Averages

7, 14, 30, 60 and 90 days

Data transfer

Integrated Bluetooth / optional USB cable

Control solution

3 levels

Auto power-off

2 minutes after the last action

Battery

2x CR 2032 3.0 V

Battery life

3,000 measurements

CND code

W0101050205

EAN

8023279241143

Regulatory standard

ISO 15197:2013 / EN ISO 15197:2015

Contents

10 strips, control solution, 10 sterile lancets, lancet, transparent cap, case, multilingual manual (GB, FR, IT, ES, PT, DE)

Languages

GB, FR, IT, ES, PT, DE

Presentacion

Unit

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📄 Technical sheet / test reportScheda di sicurezza PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Blood glucose meter Glucose Monitor Kit mg/dL with Bluetooth | Ref. 24114 | Blood Glucose Self-Monitoring Kit”

Your email address will not be published. Required fields are marked *