Description
Precise control of intra-abdominal pressure in intensive care
The UROSID® IAP manometer from Medline is the technical ally that intensive care and urology departments need to monitor the intra-abdominal pressure of bedridden patients. Its use contributes to early detection of intra-abdominal hypertension, allowing timely action and reducing associated complications. A disposable, sterile and latex-free device, designed for safe monitoring for both the patient and the care team.
Technical explanation of the device
The UROSID® IAP manometer is a pressure measurement device that is placed between the Foley catheter and the urine meter, playing an essential role during the patient’s bladder catheterisation. Through the urine column, the manometer directly reflects intra-abdominal pressure on the graduated scale, without requiring complex electronic equipment: an optimal, low-cost per-patient solution for haemodynamic control in the ICU, operating theatre and critical care units.
Technical specifications
| Characteristic | Specification |
|---|---|
| Brand | UROSID® (urology portfolio from Medline) |
| Function | Intra-abdominal pressure measurement (PAI/IAP) |
| Connection | Between Foley catheter and urine meter (Standalone) |
| Accuracy | ±5 % of the pressure reading |
| Unit of measure | mmHg |
| Measurement range | 0 to 40 mmHg |
| Indwelling time | Up to 7 days |
| Minimum patient weight | 10 kg |
| Latex-free | Yes |
| Sterile | Yes |
| Use | Single-patient (disposable) |
Available references
| Reference | Connection | Units per box |
|---|---|---|
| 690000-IAP | Standalone | 20 |
Note: the UROSID® IAP manometer is part of Medline’s urology portfolio (product family P-UY38C).
Equivalences and cross-references
The references that identify this product within Medline International’s technical documentation are 690000-IAP (order/box reference) and P-UY38C (product code), marketed under the trade name UROSID® IAP. In the Cahnos catalogue it is managed with the SKU MDLP-UY38C.
No validated equivalence table with other manufacturers is available for this specific reference. To confirm a possible stock substitution or approval in tenders, contact the technical-commercial department of Cahnos.
Selection tips and variants of interest
- Indication: monitoring of intra-abdominal pressure in hospitalised patients, especially in intensive care, surgery and critical care units, with a body weight of 10 kg or more.
- Assembly: connect the manometer between the Foley catheter and the urine meter, respecting asepsis and the manufacturer’s instructions for use (IFU) before each placement.
- Value monitoring: the scale in mmHg (0-40 mmHg) allows recording and tracking the evolution of IAP over time; in the presence of persistently elevated readings, consider the clinical suspicion of abdominal compartment syndrome.
- Rotation: as this is a single-use device with a dwell time of up to seven days, it is recommended to plan orders in full boxes of 20 units to ensure availability in the department.
- Safety: product is 100% latex-free and supplied sterile, suitable for centres with latex allergy prevention protocols.




Reviews
There are no reviews yet.