Description
The Silicone Tiemann CH14 Foley catheter is the reference solution in urology for bladder drainage when the patient’s anatomy presents difficulties: enlarged prostate, urethral strictures or tortuous passages. Its two-way design, its 5-10 ml fixation balloon and its manufacture in medical silicone make it a safe, comfortable and durable choice for permanent catheterisation, both in hospitals and in clinics and urology practices.
Description and advantages
This two-way Foley catheter is designed to provide efficient, constant and long-lasting urinary drainage. Medical silicone ensures a smooth, flexible and biocompatible surface that reduces urethral irritation, the risk of encrustation and allergic reactions, as it is completely latex-free. The result is greater patient comfort and a reduced workload for the nursing team, with less frequent catheter changes in prolonged treatments.
- Maximum biocompatibility: high-quality medical silicone, latex-free, suitable for prolonged stays.
- Tiemann-type tip: curved end with olive tip that facilitates passage through the prostatic urethra.
- Two-way: drainage channel and independent channel for balloon inflation.
- 5-10 ml balloon: secure fixation in the bladder with anti-reflux valve.
- Radiopaque line: position control via imaging along the entire length.
Technical explanation and procedure
The Foley catheter is a permanent bladder catheter that is inserted via the urethra into the bladder. In this two-way version, the main lumen allows continuous drainage of urine into the collection bag, while the secondary lumen is used to inflate the distal balloon with 5-10 ml of saline solution or sterile water, fixing the catheter in position and preventing accidental dislodgement.
The Tiemann-type tip, characterised by its curvature and terminal olive, is the great advantage of this model: it allows smooth passage through the prostatic urethra in patients with benign prostatic hyperplasia (BPH), urethral stricture, sphincter spasm or any obstruction that makes catheterisation with straight-tip catheters difficult. It is a single-use, sterile device that must be used following an aseptic technique and connected to a closed drainage system to minimise the risk of urinary tract infection (UTI).
Technical specifications
| Characteristic | Specification |
|---|---|
| Type | Tiemann-type Foley catheter, curved end with olive tip |
| Material | Transparent medical silicone, latex-free |
| Gauge | CH 14 (14 Fr, external diameter approx. 4.7 mm) |
| Number of ways | 2 (drainage and balloon) |
| Cuff | 5-10 ml, with non-return valve |
| Length | 40 cm |
| Radiopaque line | Yes, radiopaque throughout the catheter body |
| Sterilisation | Sterile, single-use |
| Presentation | Box of 10 units |
| Intended use | Transurethral bladder drainage, temporary or prolonged, in difficult anatomy |
The Tiemann silicone range with 5-10 ml balloon is available in several sizes to suit each patient:
| Gauge | Reference | Cuff | Length |
|---|---|---|---|
| CH 12 | 653012 | 5-10 ml | 40 cm |
| CH 14 | 653014 | 5-10 ml | 40 cm |
| CH 16 | 653016 | 5-10 ml | 40 cm |
| CH 18 | 653018 | 5-10 ml | 40 cm |
| CH 20 | 653020 | 5-10 ml | 40 cm |
Equivalences and cross-references
This two-way Tiemann-type silicone Foley catheter with 5-10 ml balloon in size CH 14 is equivalent, in specifications and clinical use, to the following common market references:
- Reference 23.000.20.214: Tiemann-type catheter, two-way, 5-10 ml balloon, CH 14, from international silicone balloon catheter ranges (Rüsch/Teleflex-type urinary drainage families).
- Reference 097.14: two-way silicone Tiemann catheter, radiopaque line and connector with non-return valve, size 14, available from specialised distributors (Zhanjiang Star-type range).
- UROSID® range: 10 ml silicone Foley catheters with Tiemann tip (Medline), same indications for bladder drainage in male patients.
- Dahlhausen range: Tiemann catheter with silicone balloon, 100 % silicone, curved tip for prostatic obstruction.
All share the same principle: biocompatible silicone, curved olive tip, double lumen and low-volume balloon for bladder fixation.
Selection tips and variants of interest
- Size selection: CH 14 is the usual size of choice in adults with abundant flow and good tolerance; if less trauma or marked stricture is required, consider CH 12 (ref. 653012), and for wider or post-surgical drainage, CH 16 to CH 20 (refs. 653016, 653018, 653020).
- Catheterisation duration: silicone is the recommended material for prolonged stays (up to 12 weeks per protocol), due to its low encrustation and high tolerance; for short stays, a silicone-coated latex catheter may be considered.
- Coated variant: if the priority is to prevent catheter-associated urinary tract infections, consult the silicone Foley catheter with syringe and Glyco-SID coating in size CH 14 (ref. 642014-P).
- Complementary accessories: to complete the closed system we recommend a urinary drainage bag, catheter fixation device, sterile urological lubricant and catheterisation kit with aseptic technique.
- Correct balloon use: inflate with 5-10 ml of sterile solution respecting the indicated maximum volume to avoid bladder injury, and always deflate before removal.



Reviews
There are no reviews yet.