Description
Silicone Foley Catheter Nelaton Type CH18
The Silicone Foley Catheter Nelaton Type, CH18 gauge and 5-15 ml retention balloon, is a professional urological catheter designed for urinary drainage in adult patients requiring a higher flow rate. It combines the secure balloon fixation of a Foley catheter with the characteristic straight path of the Nelaton catheter, achieving direct, atraumatic insertion with minimal friction, especially recommended for patients with urethral sensitivity or complex anatomies. It is the reliable choice for urology departments, hospitalisation, intensive care and home care.
Technical explanation and operation
The Foley catheter is a retention urethral catheter that is inserted through the urethra into the bladder. This two-way version integrates two independent channels in the same body: a main drainage channel through which urine flows into the collection bag and a secondary inflation channel connected to the retention balloon, which is filled with sterile water or physiological saline (5-15 ml) and anchors the catheter inside the bladder, preventing accidental displacement. The straight distal Nelaton-type tip, with lateral drainage holes, ensures continuous and effective flow. The CH18 gauge (18 Fr / Charrière) offers a generous diameter, indicated when abundant, dense urine or urine with blood remnants needs to be drained. 100% medical silicone, latex-free, is an inert and biocompatible material that reduces the risk of urethral irritation, minimises encrustation formation and prolongs its duration in medium and long-term use.
Technical specifications
| Specification | Detail |
|---|---|
| Type | Two-way straight Nelaton-type Foley catheter |
| Material | 100% medical silicone (latex-free) |
| Gauge | CH18 (18 Fr / Charrière) |
| Balloon capacity | 5-15 ml (recommended volume: 10 ml) |
| Length | 40 cm |
| Number of ways | 2 (drainage and balloon) |
| Distal end | Straight Nelaton tip, with lateral drainage eyes |
| Indication | High-flow urinary drainage in adults |
| Use | Urinary catheterisation and bladder catheterisation |
| Sterilisation | Sterile, single-use, individually packaged |
| Presentation | Box of 10 units |
| Reference | 642118 |
Calibre range of the two-way series with 5-15 ml balloon (length 40 cm):
| Reference | Gauge | Cuff | Ways |
|---|---|---|---|
| 642112 | CH12 | 5-15 ml | 2 |
| 642114 | CH14 | 5-15 ml | 2 |
| 642116 | CH16 | 5-15 ml | 2 |
| 642118 | CH18 | 5-15 ml | 2 |
| 642120 | CH20 | 5-15 ml | 2 |
| 642122 | CH22 | 5-15 ml | 2 |
| 642124 | CH24 | 5-15 ml | 2 |
Equivalences and cross-references
Reference 642118 falls within the standard of 100% silicone two-way Foley catheters with Nelaton-type tip and 5-15 ml balloon used in the European hospital environment. By specifications (CH18, 5-15 ml balloon, silicone, prolonged use), it is comparable and interchangeable, without changes in protocol or connection accessories, with the 100% silicone catheter series from manufacturers such as B.Braun, the Silkolatex range and the Rüsch Brillant series from Teleflex (type ref. 186005, cylindrical tip, CH12-30, 5-15 ml balloon, approx. 40 cm length), as well as with the two-way silicone models from Coloplast, ConvaTec and Bard. In Cahnos, its direct equivalent in the same CH18 gauge with a larger balloon is reference 643018 (30 ml balloon), and if simultaneous bladder irrigation is required, the three-way version 644018 can be considered.
Selection tips and variants of interest
The CH18 gauge is indicated for adults requiring a high drainage flow rate; for standard catheterisation, intermediate gauges such as CH16 are recommended, while CH20 to CH24 are reserved for higher flow requirements. For medium and long-term catheterisation, 100% silicone is the preferred option due to its low tissue reactivity and lower adherence of urinary salts, especially in patients with latex allergy. Before each use, check the integrity of the sterile packaging and inflate the balloon with the recommended volume (5-15 ml) only after confirming correct bladder placement. If greater fixation is needed in high-volume drainage, consider the series with a 30 ml balloon (ref. 643018 in CH18); if continuous bladder irrigation is required, opt for the three-way version (ref. 644018). To complete the closed drainage system, we recommend combining it with our urine bags. Consult our technical-commercial team for personalised advice and volume purchase conditions for hospitals and purchasing centres.



Reviews
There are no reviews yet.