We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Paediatric Silicone Foley Catheter CH 10 (10 Fr) | Balloon 3-5 ml | Length 31 mm | Latex-Free

34,65 €

Paediatric silicone Foley catheter CH 10 with a 3-5 ml balloon and 31 mm length, designed for safe and effective urinary drainage in paediatric patients. Manufactured from biocompatible medical silicone, latex-free, it offers smooth insertion, excellent tissue tolerance and a lower risk of irritation and encrustation. Indicated for post-surgical and therapeutic management in children, as well as for medium and long-term bladder catheterisation in paediatrics. Sterile, single-use product with a non-return valve for balloon inflation. Reference Cahnos 641010.

International shipping. Import duties and taxes are payable by the recipient.

Reference
641010

Description

Introduction

The Paediatric Silicone Foley Catheter CH 10 is the reference solution for urinary drainage in paediatric patients. Its reduced calibre, low-volume balloon (3-5 ml) and length adapted to the child’s anatomy make it the safe and comfortable choice for paediatric services, children’s hospitalisation units, post-surgical care and home care. Manufactured entirely from high-quality medical silicone, latex-free, it guarantees maximum biocompatibility, minimal urethral irritation and continuous, efficient drainage throughout the entire dwell time.

Technical explanation and procedure

The Foley catheter is a retention bladder catheter inserted via the urethra into the bladder to drain urine in a controlled manner. In this paediatric version, the main lumen allows continuous drainage into the collection bag, while a second lumen communicates with the distal fixation balloon of 3-5 ml, which is inflated with sterile water or physiological saline once correct bladder placement is confirmed. The non-return valve keeps the balloon inflated and prevents accidental catheter dislodgement. Medical silicone, an inert and biocompatible material, reduces friction, minimises the risk of encrustation and allergic reactions, and allows prolonged dwell times with complete safety, always using aseptic technique and a closed drainage system.

Technical specifications

Characteristic Specification
Type Paediatric silicone Foley catheter
Gauge CH 10 (10 Fr, Charrière scale)
Material High-quality medical silicone, latex-free
Cuff 3-5 ml, with non-return valve
Length 31 mm
Ways 2 (drainage and balloon)
Intended use Paediatric, post-surgical and therapeutic urinary drainage
Population Paediatric and infant patients
Sterility Sterile, single-use
Reference 641010

Available paediatric range (3-5 ml balloon):

Gauge Reference Cuff Length
CH 08 641008 3-5 ml 31 mm
CH 10 641010 3-5 ml 31 mm

Equivalences and cross-references

By specifications and clinical use, this paediatric silicone Foley catheter with a 3-5 ml balloon in CH 10 calibre is comparable to the two-way paediatric silicone Foley catheters of the main European manufacturers, such as the paediatric silicone ranges from Teleflex/Rüsch, Bard and Coloplast, as well as the UROSID® paediatric series from Medline with low-volume balloon. The direct correspondence between the Charrière scale (CH) and the French scale (Fr) makes this reference interchangeable with any CH 10 silicone Foley catheter from other approved suppliers, provided that balloon, length and material are verified. In the Cahnos catalogue, the family of silicone Foley catheters for adults is covered by the 5-15 ml balloon series (refs. 6421xx), the 5-10 ml Tiemann-type balloon series (refs. 6530xx) and the 10 ml balloon with Glyco-SID coating (refs. 6420xx-P).

Selection tips and variants of interest

Select the calibre adapted to the patient’s age and anatomy: CH 08 (ref. 641008) is recommended for infants and smaller children, while CH 10 (ref. 641010) is suitable for older children and for procedures requiring wider drainage. Always inflate the balloon with the indicated volume (3-5 ml), only after confirming correct bladder placement, and deflate it before removal. Silicone is the recommended material for prolonged dwell times due to its low encrustation and high tolerance. To complete the closed drainage system, a urine collection bag, catheter fixation device and sterile urological lubricant are recommended. For volume orders intended for hospitals and purchasing centres, please consult our technical-commercial team.

Additional information

Material

High-quality medical silicone (latex-free)

Gauge

CH 10 (10 Fr)

Balloon

3-5 ml

Number of ways

2 (drainage and balloon)

Product type

Paediatric Foley catheter

Target population

Paediatric patients

Use

Post-surgical and therapeutic urinary drainage

Sterilisation

Sterile, single-use

Reference

641010

Longitud

31 cm

Reviews

There are no reviews yet.

Be the first to review “Paediatric Silicone Foley Catheter CH 10 (10 Fr) | Balloon 3-5 ml | Length 31 mm | Latex-Free”

Your email address will not be published. Required fields are marked *