Description
1. Introduction
The two-way silicone-coated latex Foley catheter with Tiemann tip, reference 665016, is a single-use medical device designed for effective and safe bladder urinary drainage in hospital, clinical and post-surgical settings. Its CH 16 size, 5-10 ml retention balloon and 40 cm length make it a versatile and cost-effective option for urology, surgery, intensive care and home care services. The silicone coating reduces friction during insertion, improves patient tolerance and minimises irritation of the urethral mucosa and encrustation.
2. Technical Explanation
The Foley catheter is a double-lumen (two-way) urethral catheter that is inserted through the urethra into the urinary bladder. One lumen allows continuous drainage of urine into the collection bag, while the second lumen communicates with the 5-10 ml fixation balloon which, once inflated with sterile water or physiological saline, anchors the catheter in position and prevents its displacement or involuntary removal during treatment or post-operative recovery.
The Tiemann variant is distinguished by its curved distal end with an olive tip, a classic design in urology that facilitates passage through natural anatomical curvatures and areas of resistance, such as in male patients with benign prostatic hyperplasia, urethral stricture or after urological surgery. The CH 16 (16 Fr) size is a very common standard in adults, offering an optimal balance between drainage flow and patient comfort.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Catheter type | Two-way Foley with Tiemann tip (curved end with olive) |
| Number of ways | 2 (urinary drainage + fixation balloon inflation) |
| Material | Medical-grade latex with silicone coating |
| Size / calibre | CH 16 (16 Fr / French, approx. 5.3 mm external diameter) |
| Balloon capacity | 5-10 ml |
| Length | 40 cm |
| Tip | Tiemann, curved with olive tip |
| Connection | Luer-type connector for inflation syringe |
| Intended use | Continuous bladder urinary drainage, medical and post-operative |
| Presentation | Sterile, single-use |
| Reference | 665016 |
Range of sizes available in the same family (series 6650xx, balloon 5-10 ml):
| Reference | Gauge | Cuff | Length |
|---|---|---|---|
| 665012 | CH 12 | 5-10 ml | 40 cm |
| 665014 | CH 14 | 5-10 ml | 40 cm |
| 665016 | CH 16 | 5-10 ml | 40 cm |
| 665018 | CH 18 | 5-10 ml | 40 cm |
| 665020 | CH 20 | 5-10 ml | 40 cm |
4. Equivalences and Cross-References
This two-way silicone-coated latex Foley catheter with Tiemann tip, 5-10 ml balloon and 40 cm length is clinically comparable to the Tiemann Foley catheter series from the main manufacturers on the European market:
- Teleflex / Rüsch: series 186505 (Tiemann Foley catheter, calibres CH 12-24, balloon 5-15 ml, length approx. 40 cm).
- Teleflex (OB series): references such as 23,000.xx.214 (two-way Tiemann catheter with 5-10 ml balloon), always verifying size, balloon and length.
- B. Braun and Bard (BD group): ranges of silicone-coated latex transurethral catheters with balloon.
The CH 16 size is equivalent to 16 Fr (French scale), with an approximate external diameter of 5.3 mm. The direct correspondence between the Charrière (CH) and French (Fr) scales makes this reference interchangeable with any CH 16 silicone-coated latex Tiemann Foley catheter from other approved suppliers, provided that balloon, length and material are verified.
Internal equivalents Cahnos: reference 653016 (pure silicone Foley catheter, Tiemann type CH 16) is its latex-free alternative, recommended for prolonged catheterisation or allergic patients; the variant with 30 ml balloon of the same series is reference 666016.
5. Selection tips and variants of interest
- Select the Tiemann tip when the patient has prostatic hypertrophy, strictures or tortuous anatomy: the curvature facilitates advancement and avoids retries during catheterisation.
- The 5-10 ml balloon is suitable for standard bladder fixation in adults. Always inflate with the recommended volume (sterile water or physiological saline) to avoid leaks or injuries.
- The CH 16 size is a common intermediate size in adults that ensures good drainage flow with comfort; always choose the smallest size that ensures adequate drainage.
- Silicone-coated latex is a cost-effective alternative with good biocompatibility; in case of latex allergy or long-term catheterisation, consider pure silicone catheters (ref. 653016).
- For other sizes, review the variants in the same range: CH 12, CH 14, CH 18 and CH 20 (refs. 665012, 665014, 665018 and 665020), all with 5-10 ml balloon and 40 cm length, as well as the 6660xx series with 30 ml balloon.
- Always use a compatible water-soluble lubricant and aseptic technique, and connect the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection. Consult the technical data sheet and instructions for use before each procedure.





Reviews