Description
Professional urinary drainage with bladder irrigation
The Siliconised Latex Three-Way Nelaton-type Foley Catheter CH 18 is a retention urological catheter designed for urology, hospitalisation, surgery and intensive care services. Its triple-lumen configuration combines efficient, controlled drainage with the ability to perform bladder washouts without removing the device, making it an essential tool in the postoperative management of the bladder, haematuria and the prevention of obstructions caused by clots or sediment. A reliable, safe and cost-effective solution for hospitals, clinics and social healthcare centres.
What it is and how it works
The three-way Foley catheter integrates three independent channels in a single silicone-coated latex body: a drainage channel through which urine flows into the collection bag, an inflation channel connected to the 30 ml retention balloon that anchors the catheter in the bladder preventing accidental displacement, and a third irrigation or injection channel that allows intermittent or continuous bladder washouts and the administration of therapeutic or antiseptic solutions without the need to reposition the catheter. The straight distal Nelaton tip, with lateral drainage eyes, facilitates linear, atraumatic insertion, while the silicone coating minimises urethral irritation and improves biocompatibility during the indwelling period. Its valve is compatible with Luer and Luer-Lock syringes, ensuring seamless integration into your facility without protocol changes.
Technical specifications
| Type | Straight Nelaton-type three-way Foley catheter |
| Material | High-quality latex with silicone coating (siliconised latex) |
| Gauge | CH 18 (18 Fr / Charrière) |
| Cuff | 30 ml |
| Length | 40 cm |
| Number of ways | 3 (drainage, balloon and irrigation/injection) |
| Distal end | Straight Nelaton tip, with lateral drainage eyes |
| Valve | Compatible with Luer and Luer-Lock syringes |
| Use | Urinary drainage and simultaneous fluid management in adults |
| Sterility | Sterile, single-use |
| Presentation | Box of 10 units |
| Reference | 668018 |
Size range of the siliconised latex three-way series (30 ml balloon, 40 cm length):
| Reference | Gauge | Cuff | Ways |
|---|---|---|---|
| 668016 | CH 16 | 30 ml | 3 |
| 668018 | CH 18 | 30 ml | 3 |
| 668020 | CH 20 | 30 ml | 3 |
| 668022 | CH 22 | 30 ml | 3 |
| 668024 | CH 24 | 30 ml | 3 |
| 668026 | CH 26 | 30 ml | 3 |
Equivalences and cross-references
This catheter conforms to the standard of three-way siliconised latex Foley catheters with Nelaton tip and 30 ml balloon used in the European hospital setting. By specifications (CH 18, 30 ml balloon, three-way, Nelaton tip), it is comparable and interchangeable, without changes to protocol or connection accessories, with the three-way siliconised latex Foley catheters of the Teleflex Rüsch Gold series (reference type 183430 in sizes CH 18-26) and with the three-way siliconised latex ranges from Bard, Coloplast and B.Braun for postoperative drainage and bladder irrigation. Within the Cahnos catalogue, the direct equivalent in 100 % latex-free silicone for the same size and configuration is reference 644018 (series 644016 to 644024), recommended for patients with latex allergy or prolonged catheterisation. If the clinical indication does not require irrigation, the two-way version with 30 ml balloon (ref. 643018) or the one with 5-15 ml balloon (ref. 642118) may be considered.
Selection tips and variants of interest
The CH 18 size is a common choice for catheterisation of the adult patient when a generous drainage flow rate and the possibility of bladder irrigation are required. To select the appropriate size, consider the urethral diameter, the clinical indication and the expected duration of catheterisation: in the same family of three-way siliconised latex with 30 ml balloon, sizes CH 16 (ref. 668016), CH 20 (ref. 668020), CH 22 (ref. 668022), CH 24 (ref. 668024) and CH 26 (ref. 668026) are available. For patients with latex allergy, the recommended alternative is the 100 % silicone series (refs. 644016 to 644024). If the clinical indication does not require irrigation, the two-way Foley catheter with 30 ml balloon (ref. 643018) may be considered. To complete the closed drainage system, we recommend combining it with our urine collection bags. Consult our technical-commercial team for personalised advice and volume purchase conditions for hospitals and purchasing groups.



Reviews
There are no reviews yet.