Siliconised Latex Three-Way Nelaton-type Foley Catheter | 30 ml Balloon | CH 18 (18 Fr) | 40 cm Length

10,47 €

Three-way Nelaton-type siliconised latex Foley catheter, size CH 18 (18 Fr), with a 30 ml retention balloon and 40 cm length. Designed for continuous urinary drainage in adult patients and for procedures requiring bladder irrigation or simultaneous lavage, thanks to its third independent channel that allows the administration of therapeutic or antiseptic solutions without removing the catheter. Its siliconised surface reduces friction during insertion and improves tolerance in short- and medium-term catheterisation. Valve compatible with Luer and Luer-Lock syringes, atraumatic rounded tip and sterile single-use presentation in a box of 10 units. Ref. 668018.

International shipping. Import duties and taxes are payable by the recipient.

Reference
668018
Tags

Description

Professional urinary drainage with bladder irrigation

The Siliconised Latex Three-Way Nelaton-type Foley Catheter CH 18 is a retention urological catheter designed for urology, hospitalisation, surgery and intensive care services. Its triple-lumen configuration combines efficient, controlled drainage with the ability to perform bladder washouts without removing the device, making it an essential tool in the postoperative management of the bladder, haematuria and the prevention of obstructions caused by clots or sediment. A reliable, safe and cost-effective solution for hospitals, clinics and social healthcare centres.

What it is and how it works

The three-way Foley catheter integrates three independent channels in a single silicone-coated latex body: a drainage channel through which urine flows into the collection bag, an inflation channel connected to the 30 ml retention balloon that anchors the catheter in the bladder preventing accidental displacement, and a third irrigation or injection channel that allows intermittent or continuous bladder washouts and the administration of therapeutic or antiseptic solutions without the need to reposition the catheter. The straight distal Nelaton tip, with lateral drainage eyes, facilitates linear, atraumatic insertion, while the silicone coating minimises urethral irritation and improves biocompatibility during the indwelling period. Its valve is compatible with Luer and Luer-Lock syringes, ensuring seamless integration into your facility without protocol changes.

Technical specifications

Type Straight Nelaton-type three-way Foley catheter
Material High-quality latex with silicone coating (siliconised latex)
Gauge CH 18 (18 Fr / Charrière)
Cuff 30 ml
Length 40 cm
Number of ways 3 (drainage, balloon and irrigation/injection)
Distal end Straight Nelaton tip, with lateral drainage eyes
Valve Compatible with Luer and Luer-Lock syringes
Use Urinary drainage and simultaneous fluid management in adults
Sterility Sterile, single-use
Presentation Box of 10 units
Reference 668018

Size range of the siliconised latex three-way series (30 ml balloon, 40 cm length):

Reference Gauge Cuff Ways
668016 CH 16 30 ml 3
668018 CH 18 30 ml 3
668020 CH 20 30 ml 3
668022 CH 22 30 ml 3
668024 CH 24 30 ml 3
668026 CH 26 30 ml 3

Equivalences and cross-references

This catheter conforms to the standard of three-way siliconised latex Foley catheters with Nelaton tip and 30 ml balloon used in the European hospital setting. By specifications (CH 18, 30 ml balloon, three-way, Nelaton tip), it is comparable and interchangeable, without changes to protocol or connection accessories, with the three-way siliconised latex Foley catheters of the Teleflex Rüsch Gold series (reference type 183430 in sizes CH 18-26) and with the three-way siliconised latex ranges from Bard, Coloplast and B.Braun for postoperative drainage and bladder irrigation. Within the Cahnos catalogue, the direct equivalent in 100 % latex-free silicone for the same size and configuration is reference 644018 (series 644016 to 644024), recommended for patients with latex allergy or prolonged catheterisation. If the clinical indication does not require irrigation, the two-way version with 30 ml balloon (ref. 643018) or the one with 5-15 ml balloon (ref. 642118) may be considered.

Selection tips and variants of interest

The CH 18 size is a common choice for catheterisation of the adult patient when a generous drainage flow rate and the possibility of bladder irrigation are required. To select the appropriate size, consider the urethral diameter, the clinical indication and the expected duration of catheterisation: in the same family of three-way siliconised latex with 30 ml balloon, sizes CH 16 (ref. 668016), CH 20 (ref. 668020), CH 22 (ref. 668022), CH 24 (ref. 668024) and CH 26 (ref. 668026) are available. For patients with latex allergy, the recommended alternative is the 100 % silicone series (refs. 644016 to 644024). If the clinical indication does not require irrigation, the two-way Foley catheter with 30 ml balloon (ref. 643018) may be considered. To complete the closed drainage system, we recommend combining it with our urine collection bags. Consult our technical-commercial team for personalised advice and volume purchase conditions for hospitals and purchasing groups.

Additional information

Material

High-quality latex with silicone coating (siliconised latex)

Gauge

CH 18 (18 Fr / Charrière)

Balloon

30 ml

Number of ways

3 (drainage, balloon and irrigation/injection)

Distal end

Straight Nelaton tip, with lateral drainage eyes

Valve

Compatible with Luer and Luer-Lock syringes

Use

Urinary drainage and simultaneous fluid management in adults

Sterility

Sterile, single-use

Presentation

Box of 10 units

Reference

668018

Longitud

40 cm

Reviews

There are no reviews yet.

Be the first to review “Siliconised Latex Three-Way Nelaton-type Foley Catheter | 30 ml Balloon | CH 18 (18 Fr) | 40 cm Length”

Your email address will not be published. Required fields are marked *