Description
1. Introduction
The two-way silicone-coated latex Foley catheter with Nelaton tip, CH 14 gauge and 30 ml balloon (ref. 663014) is a single-use indwelling urethral catheter, manufactured from medical-grade latex with a silicone coating. It is indicated for effective, continuous and controlled urinary drainage in adult and paediatric patients, in urology, hospitalisation, surgery, intensive care and post-surgical care services.
Its excellent value for money makes it a reliable and economical solution for hospitals, clinics, social healthcare centres and healthcare professionals who need a constant, approved supply for the management of bladder catheterisation.
2. Technical explanation of the device
The Foley catheter is an indwelling urinary catheter that is inserted through the urethra into the bladder. This two-way version integrates two independent channels in a single body: a main drainage channel through which urine flows into the collection bag and a secondary inflation channel connected to the 30 ml retention balloon. Once the catheter is placed and correct bladder position is confirmed, the balloon is filled with sterile water or physiological saline, anchoring the catheter and preventing accidental displacement during treatment or postoperative recovery.
The straight Nelaton tip, with lateral drainage eyes, facilitates linear and atraumatic insertion. The silicone coating over the latex reduces friction on the urethral mucosa, minimises the risk of irritation and encrustation and improves tolerance in short- and medium-term catheterisations. The CH 14 (14 Fr) gauge offers an excellent balance between drainage flow and comfort, being one of the sizes most commonly used in standard adult catheterisation.
3. Technical Specifications
| Characteristic | Detail |
| Catheter type | Straight two-way Foley catheter with Nelaton tip |
| Material | Medical-grade latex with silicone coating |
| Number of ways | 2 (urinary drainage + balloon inflation) |
| Gauge | CH 14 (14 Fr / Charrière-French scale; external diameter approx. 4.7 mm) |
| Balloon capacity | 30 ml |
| Length | 40 cm |
| Distal end | Straight Nelaton tip, with lateral drainage eyes |
| Connection | Valve compatible with Luer-type syringe; connector for urine collection bag |
| Intended use | Continuous and post-surgical bladder urinary drainage in adults and children |
| Sterility | Sterile, single-use, individually packaged |
| Presentation | Box of 10 units |
| Reference | 663014 |
Range of calibres in the two-way Nelaton series with 30 ml balloon (length 40 cm):
| Reference | Gauge | Cuff | Ways |
| 663012 | CH 12 | 30 ml | 2 |
| 663014 | CH 14 | 30 ml | 2 |
| 663016 | CH 16 | 30 ml | 2 |
| 663018 | CH 18 | 30 ml | 2 |
| 663020 | CH 20 | 30 ml | 2 |
| 663022 | CH 22 | 30 ml | 2 |
| 663024 | CH 24 | 30 ml | 2 |
| 663026 | CH 26 | 30 ml | 2 |
4. Equivalences and Cross-References
By specifications (CH 14 gauge, 30 ml balloon, two-way, Nelaton tip and silicone-coated latex), this catheter is comparable and interchangeable with 14 Fr silicone-coated latex Foley catheters from manufacturers such as Rüsch/Teleflex, Bard (BD group), Coloplast or B. Braun, without the need to modify the insertion protocol or connection accessories. The Charrière (CH) scale is directly equivalent to the French (Fr) scale, so the CH 14 gauge is interchangeable, always checking balloon, length and material.
Within the Cahnos catalogue, the same two-way Nelaton configuration with a 5-10 ml balloon corresponds to the 6620xx series (ref. 662014 in CH 14); the version with Tiemann tip and 30 ml balloon corresponds to the 6660xx series (ref. 666014 in CH 14), recommended for complex prostatic anatomy or strictures; and if simultaneous bladder irrigation is required, the three-way version (ref. 668014) may be considered. For patients with latex allergy or medium- and long-term catheterisation, the 100% silicone range (ref. 643014 in CH 14) is recommended, allowing all bladder drainage cases to be covered with a single supplier.
5. Selection tips and variants of interest
Always select the smallest gauge that ensures adequate drainage under medical criteria: CH 14, CH 16 and CH 18 are the most common sizes in standard adult catheterisation, while CH 20 and above are reserved for high-flow requirements, urine with sediment, haematuria or higher-flow post-surgical drainage.
The 30 ml balloon offers a larger fixation surface and a lower risk of accidental expulsion than 5-10 ml balloons, and is recommended for urinary retention requiring assisted bladder emptying. Inflate the balloon only after confirming correct bladder placement, with the recommended volume of sterile water or physiological saline, and use a compatible water-soluble lubricant and aseptic technique. Connect the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection and check the integrity of the sterile packaging before each use.
To complete the drainage system, we recommend combining this catheter with our urine collection bags. Contact our technical-commercial team for special volume purchase conditions for hospitals and purchasing groups.





Reviews
There are no reviews yet.