Description
Professional urinary drainage with siliconised latex Foley catheter
The two-way siliconised latex Foley catheter with Nelaton tip, CH 24 (24 Fr) gauge and rubber valve is a single-use retention urethral catheter, manufactured from medical-grade latex with a silicone coating. With a 5-10 ml balloon and 40 cm length, it is indicated to ensure effective, safe and comfortable urinary drainage in adult patients during medical, surgical and post-surgical procedures, in urology, hospitalisation, surgery and intensive care services. A reliable and economical solution for hospitals, clinics, social-health centres and healthcare professionals who need a constant and approved supply.
Technical explanation of the device
The Foley catheter is a retention urinary catheter that is inserted through the urethra into the bladder. This two-way version integrates two independent channels in a single body: a main drainage channel through which urine flows into the collection bag and a secondary inflation channel connected to the retention balloon. Once placed, the balloon is filled with sterile water or physiological saline (5-10 ml), anchoring the catheter inside the bladder and preventing accidental displacement during treatment or postoperative recovery.
The straight Nelaton tip, with lateral drainage holes, facilitates linear and atraumatic insertion, while the silicone coating over the latex reduces friction on the urethral mucosa, minimises the risk of irritation and encrustation and promotes tolerance in short- and medium-term catheterisation. The rubber valve allows the balloon to be inflated with a Luer-type syringe and guarantees a hermetic seal of the system during the indwelling time. The CH 24 (24 Fr) gauge offers a wide drainage flow rate, ideal when a generous evacuation flow is required, such as in haematuria, urine with sediment or high-flow post-surgical drainage.
Technical specifications
| Characteristic | Detail |
| Catheter type | Two-way Foley catheter with Nelaton tip |
| Number of ways | 2 (urinary drainage + balloon inflation) |
| Material | Medical-grade latex with silicone coating (siliconised latex) |
| Gauge | CH 24 (24 Fr / Charrière scale) |
| Balloon capacity | 5-10 ml |
| Length | 40 cm |
| Valve | Rubber valve compatible with Luer-type syringe |
| Distal end | Straight Nelaton tip, with lateral drainage eyes |
| Connection | Standard connector for urine collection bag |
| Intended use | Continuous and post-surgical bladder urinary drainage in adults |
| Sterility | Sterile, single-use, individually packaged |
| Presentation | Box of 10 units |
| Reference | 662224 |
Range of gauges in the two-way Nelaton series with rubber valve and 5-10 ml balloon (length 40 cm):
| Reference | Gauge | Cuff | Ways |
| 662212 | CH 12 | 5-10 ml | 2 |
| 662214 | CH 14 | 5-10 ml | 2 |
| 662216 | CH 16 | 5-10 ml | 2 |
| 662218 | CH 18 | 5-10 ml | 2 |
| 662220 | CH 20 | 5-10 ml | 2 |
| 662222 | CH 22 | 5-10 ml | 2 |
| 662224 | CH 24 | 5-10 ml | 2 |
| 662226 | CH 26 | 5-10 ml | 2 |
Valve variants available in the two-way Nelaton series with 5-10 ml balloon in CH 24 gauge (length 40 cm):
| Reference | Gauge | Cuff | Ways | Valve |
| 662024 | CH 24 | 5-10 ml | 2 | PVC valve |
| 662224 | CH 24 | 5-10 ml | 2 | Rubber valve |
Equivalences and cross-references
By specifications (CH 24 gauge, 5-10 ml balloon, two-way, Nelaton tip and siliconised latex), this catheter is comparable and interchangeable, without the need to modify the placement protocol or connection accessories, with 24 Fr siliconised latex Foley catheters from manufacturers such as Rüsch/Teleflex (Rüsch Gold range), Bard (BD group), Coloplast or B. Braun. The Charrière (CH) scale is directly equivalent to the French (Fr) scale, so the CH 24 gauge is interchangeable, always verifying balloon, length, valve and material.
Within the Cahnos catalogue, the same two-way Nelaton configuration in CH 24 with PVC valve corresponds to reference 662024; the version with 30 ml balloon corresponds to the 6630xx series (ref. 663024 in CH 24). If simultaneous bladder irrigation is required, the three-way version (ref. 668024 in CH 24) may be considered. For patients with latex allergy or medium- and long-term catheterisation, the 100% silicone range (ref. 643024 in CH 24) is recommended, allowing all bladder drainage cases to be covered with a single supplier.
Selection tips and variants of interest
The CH 24 gauge is reserved for adult patients with high flow rate requirements, urine with sediment, haematuria or high-flow post-surgical drainage. Always select the smallest gauge that ensures adequate drainage under medical criteria, and consider smaller gauges (CH 16-22) in patients with a narrower urethra or less demanding catheterisation, and CH 26 when an even higher flow rate is required. The 5-10 ml balloon is the usual option for bladder fixation in short- and medium-term catheterisation, offering a lower volume profile and great comfort.
Inflate the balloon only after confirming correct bladder placement, with the recommended volume of sterile water or physiological saline, and use a compatible water-soluble lubricant and aseptic technique. Connect the collection bag with a closed system to minimise the risk of catheter-associated urinary infection and check the integrity of the sterile packaging before each use. To complete the drainage system, we recommend combining this catheter with our urine collection bags. Consult our technical-commercial team for special volume purchase conditions for hospitals and purchasing centres.





Reviews