We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Silicone-Coated Latex Foley Catheter Two-Way Nelaton Type | Rubber Valve | Balloon 5-10 ml | CH 18 (18 Fr) | Length 40 cm | Sterile Urinary Catheter for Adults

7,93 €

Two-way silicone-coated latex Foley catheter with Nelaton tip, CH 18 (18 Fr) calibre, 5-10 ml retention balloon, rubber valve and 40 cm length. Sterile single-use medical device, designed for continuous and postoperative urinary drainage in adult patients. Its silicone coating reduces friction on the urethral mucosa, facilitates comfortable and atraumatic insertion and minimises the risk of irritation and encrustation. Includes rubber valve compatible with Luer-type syringe and standard connector for urine collection bag. Presentation in box of 10 units. Ref. 662218.

International shipping. Import duties and taxes are payable by the recipient.

Reference
662218

Description

1. Introduction

The two-way silicone-coated latex Foley catheter with Nelaton tip, CH 18 (18 Fr) calibre, 5-10 ml retention balloon, rubber valve and 40 cm length is a single-use urethral retention catheter, manufactured from medical-grade latex with a silicone coating. It is indicated for effective and controlled urinary drainage in adult patients in urology, hospitalisation, surgery, intensive care and postoperative care departments. Its excellent value for money and its configuration with a rubber valve make it a reliable and economical solution for hospitals, clinics, social healthcare centres and healthcare professionals who require a constant and approved supply.

2. Technical explanation of the device

The Foley catheter is a urinary retention catheter that is inserted through the urethra into the bladder. This two-way version integrates two independent channels in the same body: a main drainage channel through which urine flows into the collection bag and a secondary inflation channel connected to the retention balloon. Once the catheter is placed, the balloon is filled with sterile water or physiological saline (up to 10 ml), which anchors the catheter inside the bladder and prevents accidental displacement during treatment or postoperative recovery.

The straight Nelaton-type tip, with lateral drainage holes, facilitates linear and atraumatic insertion, while the silicone coating on the latex reduces friction on the urethral mucosa, minimises the risk of irritation and encrustation and promotes tolerance in short- and medium-term catheterisation. The rubber valve allows the balloon to be inflated with a Luer-type syringe and guarantees a hermetic seal of the system during the indwelling period. The CH 18 (18 Fr) calibre is one of the most common in standard adult catheterisation, offering a generous drainage flow rate and excellent compatibility with the average urethral anatomy.

3. Technical Specifications

Characteristic Detail
Catheter type Two-way Foley catheter with Nelaton tip
Number of ways 2 (urinary drainage + balloon inflation)
Material Medical-grade latex with silicone coating (siliconised latex)
Gauge CH 18 (18 Fr / Charrière scale)
Balloon capacity 5-10 ml
Length 40 cm
Valve Rubber valve compatible with Luer-type syringe
Distal end Straight Nelaton tip, with lateral drainage eyes
Connection Standard connector for urine collection bag
Intended use Continuous and post-surgical bladder urinary drainage in adults
Sterility Sterile, single-use, individually packaged
Presentation Box of 10 units
Reference 662218

Valve variants available in the two-way Nelaton series with 5-10 ml balloon (CH 18 calibre, 40 cm length):

Reference Gauge Cuff Ways Valve
662018 CH 18 5-10 ml 2 PVC valve
662218 CH 18 5-10 ml 2 Rubber valve

4. Equivalences and Cross-References

By specifications (CH 18 calibre, 5-10 ml balloon, two-way, Nelaton tip and silicone-coated latex), this catheter is comparable and interchangeable, without the need to modify the placement protocol or connection accessories, with 18 Fr silicone-coated latex Foley catheters from manufacturers such as Rüsch/Teleflex, Bard (BD group), Coloplast or B. Braun. The Charrière (CH) scale is directly equivalent to the French (Fr) scale, so the CH 18 calibre is interchangeable, always verifying balloon, length, valve and material.

Within the Cahnos catalogue, the same two-way Nelaton configuration with a 30 ml balloon corresponds to the 6630xx series (ref. 663018 in CH 18); the version with a Tiemann tip and 30 ml balloon corresponds to the 6660xx series (ref. 666018 in CH 18), recommended for complex prostatic anatomy or strictures. If simultaneous bladder irrigation is required, the three-way version (ref. 668018 in CH 18) may be considered. For patients with latex allergy or medium- and long-term catheterisation, the 100% silicone range (ref. 643018) is recommended, which allows all bladder drainage cases to be covered with a single supplier.

5. Selection tips and variants of interest

The CH 18 calibre is one of the most common sizes in adult patient catheterisation, suitable for both standard drainage and high flow rate requirements, urine with sediment, haematuria or higher-flow postoperative drainage. The 5-10 ml balloon is the usual option for bladder fixation in short- and medium-term catheterisation, offering a lower volume profile and great comfort. Always select the smallest calibre that ensures adequate drainage under medical criteria.

Inflate the balloon only after confirming correct bladder placement, with the recommended volume of sterile water or physiological saline, and use a compatible water-soluble lubricant and aseptic technique. Connect the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection and check the integrity of the sterile packaging before each use. To complete the drainage system, we recommend combining this catheter with our urine collection bags. Contact our technical-commercial team for special volume purchase conditions for hospitals and purchasing centres.

Additional information

Product type

Two-way Foley catheter with Nelaton tip

Material

Medical-grade latex with silicone coating (siliconised latex)

Gauge

CH 18 (18 Fr / Charrière scale)

Balloon capacity

5-10 ml

Number of channels

2 (urinary drainage + balloon inflation)

Valve

Rubber valve compatible with Luer-type syringe

Distal end

Straight Nelaton tip, with lateral drainage eyes

Connection

Standard connector for urine collection bag

Intended use

Continuous and post-surgical bladder urinary drainage in adults

Sterility

Sterile, single-use, individually packaged

Presentation

Box of 10 units

Reference

662218

Longitud

40 cm

Reviews

There are no reviews yet.

Be the first to review “Silicone-Coated Latex Foley Catheter Two-Way Nelaton Type | Rubber Valve | Balloon 5-10 ml | CH 18 (18 Fr) | Length 40 cm | Sterile Urinary Catheter for Adults”