Silicone-coated Latex Foley Catheter Two-Way Tiemann Tip | 30 ml Balloon | CH 18 (18 Fr) | Length 40 cm | Sterile | Ref. 666018

8,93 €

Silicone-coated latex two-way Foley catheter, Tiemann tip, CH 18 (18 Fr) with 30 ml retention balloon and 40 cm length (ref. 666018). Its curved distal end with olive tip facilitates insertion in patients with prostatic hypertrophy, stricture or complex anatomy, while the silicone coating reduces friction and improves tolerance in continuous and post-surgical bladder drainage. Sterile, single-use medical device with Luer-type connector for balloon inflation. Presented in a box of 10 units, available in CH 12 to CH 20 sizes within the Tiemann 30 ml series from Cahnos.

International shipping. Import duties and taxes are payable by the recipient.

Reference
666018

Description

1. Introduction

The silicone-coated latex two-way Foley catheter with Tiemann tip, reference 666018, is a single-use medical device designed for effective and safe bladder urinary drainage in hospital, clinical and post-surgical settings. Its combination of medical-grade latex with a silicone coating provides flexibility, strength and a low-friction surface that improves patient comfort during catheterisation, reducing urethral mucosal irritation and encrustation. A reliable and cost-effective solution for urology, surgery and intensive care departments.

2. Technical Explanation

The Foley catheter is a double-lumen (two-way) urethral catheter inserted through the urethra into the urinary bladder. One lumen allows continuous drainage of urine into the collection bag, while the second lumen connects to the 30 ml retention balloon which, once inflated with saline solution or sterile water, anchors the catheter in position and prevents accidental displacement. The Tiemann variant is distinguished by its slightly curved distal end with an olive tip, a classic design in urology that facilitates passage through anatomical curves and areas of resistance, particularly in men with benign prostatic hyperplasia, urethral stricture or complex anatomy. The CH 18 (18 Fr) calibre offers a wide drainage flow rate, indicated in adults when high flow, sediment or larger-volume drainage is anticipated.

3. Technical Specifications

Characteristic Specification
Catheter type Foley with Tiemann tip (curved end with olive)
Number of ways Two-way (urinary drainage + retention balloon)
Material Medical-grade latex with silicone coating
Size / calibre CH 18 (18 Fr / French, approx. 6.0 mm external diameter)
Balloon capacity 30 ml
Length 40 cm
Connection Luer-type connector for inflation syringe
Tip Tiemann, curved with olive tip
Intended use Continuous and post-surgical bladder urinary drainage
Presentation Sterile, single-use, box of 10 units
Reference 666018

Available range from the same family (Tiemann balloon 30 ml, series 6660xx):

Reference Gauge Cuff Length
666012 CH 12 30 ml 40 cm
666014 CH 14 30 ml 40 cm
666016 CH 16 30 ml 40 cm
666018 CH 18 30 ml 40 cm
666020 CH 20 30 ml 40 cm

4. Equivalences and Cross-References

This catheter is part of the Cahnos family of silicone-coated latex two-way Tiemann-type Foley catheters. In reference sector catalogues, two-way Tiemann-type catheters with balloon are usually coded within the ranges of silicone-coated latex transurethral catheters, comparable to the Tiemann Foley series from manufacturers such as Rüsch/Teleflex, B. Braun or Bard (BD group). The CH 18 calibre is equivalent to 18 Fr (French scale), with an approximate external diameter of 6.0 mm; the direct correspondence between the Charrière (CH) and French (Fr) scales makes this reference interchangeable with any silicone-coated latex Tiemann Foley catheter CH 18 from other approved suppliers, always verifying balloon, length and material. Within the Cahnos range itself, the alternative with the same CH 18 calibre in a 5-10 ml balloon corresponds to reference 665018, and the latex-free silicone option for prolonged stays to reference 653018, allowing all bladder drainage scenarios to be covered with a single supplier.

5. Selection tips and variants of interest

Choose the Tiemann tip when the patient has prostatic hypertrophy, narrowing or tortuous anatomy: the curvature facilitates advancement and avoids repeated attempts. The 30 ml balloon provides greater fixation and a lower risk of accidental expulsion than 5-10 ml balloons, recommended in urinary retention requiring assisted or post-surgical bladder emptying. The CH 18 calibre is a common large size in adults, indicated when a generous drainage flow rate is required or in the presence of urine with sediment. Always inflate the balloon with the recommended volume and use a compatible water-soluble lubricant and aseptic technique, connecting the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection. For other calibres, review the variants of the same 6660xx series (CH 12, CH 14, CH 16 and CH 20), the 6650xx series with 5-10 ml balloon, or the 6530xx silicone catheters for prolonged catheterisation. Consult the technical data sheet and instructions for use before each procedure.

Additional information

Product type

Two-way Tiemann Foley catheter

Material

Medical-grade latex with silicone coating

Gauge

CH 18 (18 Fr)

Outer diameter

Approx. 6.0 mm

Balloon capacity

30 ml

Number of channels

2 (drainage + balloon)

Tip type

Curved Tiemann with olive tip

Connection

Luer-type connector

Use

Continuous and post-surgical bladder urinary drainage

Sterilisation

Sterile (ethylene oxide), single-use

Presentation

Box of 10 units

Reference

666018

Longitud

40 cm

Reviews