Description
1. Introduction
The silicone-coated latex Foley catheter with Tiemann tip, reference 666016, is a single-use medical device designed for effective and safe vesical urinary drainage in hospital, clinical and post-surgical settings. Its combination of medical-grade latex with silicone coating provides flexibility, strength and a low-friction surface that improves patient comfort during catheterisation, reducing urethral mucosa irritation and encrustation. A reliable and cost-effective solution for urology, surgery and intensive care departments.
2. Technical Explanation
The Foley catheter is a urethral catheter with a double lumen (two-way) that is inserted through the urethra into the urinary bladder. One lumen allows continuous drainage of urine into the collection bag, while the second lumen connects to the 30 ml retention balloon which, once inflated with sterile water or normal saline, anchors the catheter in position and prevents accidental displacement during treatment or postoperative recovery.
The Tiemann variant is distinguished by its curved distal end with olive tip, a classic design in urology that facilitates passage through anatomical curves and areas of resistance, especially in men with benign prostatic hyperplasia, urethral stricture or complex anatomy. The CH 16 (16 Fr) size offers an intermediate-to-high drainage flow rate, very common in adults, with a good balance between drainage flow and comfort.
3. Technical Specifications
| Characteristic | Specification |
| Catheter type | Foley catheter with Tiemann tip (curved end with olive) |
| Number of ways | Two-way (urinary drainage + balloon inflation) |
| Material | Medical-grade latex with silicone coating |
| Size / calibre | CH 16 (16 Fr / French, approx. 5.3 mm external diameter) |
| Balloon capacity | 30 ml |
| Length | 40 cm |
| Tip | Tiemann, curved with olive tip |
| Connection | Luer-type connector for inflation syringe |
| Intended use | Continuous and post-surgical bladder urinary drainage |
| Presentation | Sterile, single-use, box of 10 units |
| Reference | 666016 |
Available range from the same family (Tiemann balloon 30 ml, series 6660xx):
| Reference | Gauge | Cuff | Length |
| 666012 | CH 12 | 30 ml | 40 cm |
| 666014 | CH 14 | 30 ml | 40 cm |
| 666016 | CH 16 | 30 ml | 40 cm |
| 666018 | CH 18 | 30 ml | 40 cm |
| 666020 | CH 20 | 30 ml | 40 cm |
4. Equivalences and Cross-References
This catheter is part of the Cahnos family of two-way silicone-coated latex Foley catheters of Tiemann type. In the sector’s reference catalogues, two-way balloon Tiemann-type catheters are coded within the ranges of silicone-coated latex transurethral catheters, being clinically comparable to the Foley Tiemann series from manufacturers such as Rüsch/Teleflex, B. Braun or Bard (BD group).
The Charrière scale (CH) is directly equivalent to the French scale (Fr), so CH 16 size is interchangeable with any CH 16 silicone-coated latex Foley Tiemann catheter from other approved suppliers, always verifying balloon, length and material. In Cahnos’s own range, the alternative with the same CH 16 size in a 5-10 ml balloon is reference 665016, and the silicone option without latex for extended stays corresponds to series 6530xx, allowing all bladder drainage cases to be covered with a single supplier.
5. Selection tips and variants of interest
- Select the Tiemann tip when the patient has prostatic hypertrophy, narrowings or tortuous anatomy: the curvature facilitates advancement and avoids repeated attempts.
- The 30 ml balloon offers greater fixation and lower risk of accidental expulsion than the 5-10 ml ones, recommended for urinary retention requiring assisted bladder emptying or in post-surgical care.
- CH 16 size is a standard measure in adults with a good balance between drainage flow and comfort; always choose the smallest size that ensures adequate drainage.
- Inflate the balloon with sterile water or normal saline to the recommended volume and use compatible water-soluble lubricant and aseptic technique, connecting the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection.
- For other sizes, review the variants of series 6660xx (CH 12, CH 14, CH 18 and CH 20), series 6650xx with 5-10 ml balloon or silicone catheters for prolonged catheterisations.





Reviews
There are no reviews yet.