We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Foley Catheter Silicone-Coated Latex Two-Way Tiemann Tip | Balloon 30 ml | CH 16 (16 Fr) | Length 40 cm | Sterile | Ref. 666016

8,93 €

The two-way silicone-coated latex Foley catheter with Tiemann tip, size CH 16 (16 Fr) and 30 ml retention balloon, guarantees safe and effective urinary drainage in medical and post-surgical procedures. Its curved distal end with olive tip facilitates insertion in patients with prostatic hyperplasia, strictures or complex anatomy, while the silicone coating reduces friction and improves patient tolerance. Sterile single-use medical device, with independent channel for balloon inflation via Luer-type connector. Available in sizes CH 12 to CH 20 within the Cahnos Tiemann 30 ml series. Reference 666016.

International shipping. Import duties and taxes are payable by the recipient.

Reference
666016

Description

1. Introduction

The silicone-coated latex Foley catheter with Tiemann tip, reference 666016, is a single-use medical device designed for effective and safe vesical urinary drainage in hospital, clinical and post-surgical settings. Its combination of medical-grade latex with silicone coating provides flexibility, strength and a low-friction surface that improves patient comfort during catheterisation, reducing urethral mucosa irritation and encrustation. A reliable and cost-effective solution for urology, surgery and intensive care departments.

2. Technical Explanation

The Foley catheter is a urethral catheter with a double lumen (two-way) that is inserted through the urethra into the urinary bladder. One lumen allows continuous drainage of urine into the collection bag, while the second lumen connects to the 30 ml retention balloon which, once inflated with sterile water or normal saline, anchors the catheter in position and prevents accidental displacement during treatment or postoperative recovery.

The Tiemann variant is distinguished by its curved distal end with olive tip, a classic design in urology that facilitates passage through anatomical curves and areas of resistance, especially in men with benign prostatic hyperplasia, urethral stricture or complex anatomy. The CH 16 (16 Fr) size offers an intermediate-to-high drainage flow rate, very common in adults, with a good balance between drainage flow and comfort.

3. Technical Specifications

Characteristic Specification
Catheter type Foley catheter with Tiemann tip (curved end with olive)
Number of ways Two-way (urinary drainage + balloon inflation)
Material Medical-grade latex with silicone coating
Size / calibre CH 16 (16 Fr / French, approx. 5.3 mm external diameter)
Balloon capacity 30 ml
Length 40 cm
Tip Tiemann, curved with olive tip
Connection Luer-type connector for inflation syringe
Intended use Continuous and post-surgical bladder urinary drainage
Presentation Sterile, single-use, box of 10 units
Reference 666016

Available range from the same family (Tiemann balloon 30 ml, series 6660xx):

Reference Gauge Cuff Length
666012 CH 12 30 ml 40 cm
666014 CH 14 30 ml 40 cm
666016 CH 16 30 ml 40 cm
666018 CH 18 30 ml 40 cm
666020 CH 20 30 ml 40 cm

4. Equivalences and Cross-References

This catheter is part of the Cahnos family of two-way silicone-coated latex Foley catheters of Tiemann type. In the sector’s reference catalogues, two-way balloon Tiemann-type catheters are coded within the ranges of silicone-coated latex transurethral catheters, being clinically comparable to the Foley Tiemann series from manufacturers such as Rüsch/Teleflex, B. Braun or Bard (BD group).

The Charrière scale (CH) is directly equivalent to the French scale (Fr), so CH 16 size is interchangeable with any CH 16 silicone-coated latex Foley Tiemann catheter from other approved suppliers, always verifying balloon, length and material. In Cahnos’s own range, the alternative with the same CH 16 size in a 5-10 ml balloon is reference 665016, and the silicone option without latex for extended stays corresponds to series 6530xx, allowing all bladder drainage cases to be covered with a single supplier.

5. Selection tips and variants of interest

  • Select the Tiemann tip when the patient has prostatic hypertrophy, narrowings or tortuous anatomy: the curvature facilitates advancement and avoids repeated attempts.
  • The 30 ml balloon offers greater fixation and lower risk of accidental expulsion than the 5-10 ml ones, recommended for urinary retention requiring assisted bladder emptying or in post-surgical care.
  • CH 16 size is a standard measure in adults with a good balance between drainage flow and comfort; always choose the smallest size that ensures adequate drainage.
  • Inflate the balloon with sterile water or normal saline to the recommended volume and use compatible water-soluble lubricant and aseptic technique, connecting the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection.
  • For other sizes, review the variants of series 6660xx (CH 12, CH 14, CH 18 and CH 20), series 6650xx with 5-10 ml balloon or silicone catheters for prolonged catheterisations.

Additional information

Catheter type

Foley catheter with Tiemann tip (curved end with olive)

Number of ways

Two-way (urinary drainage + balloon inflation)

Material

Medical-grade latex with silicone coating

Gauge

CH 16 (16 Fr / French, approx. 5.3 mm external diameter)

Balloon capacity

30 ml

Tip

Tiemann, curved with olive tip

Connection

Luer-type connector for inflation syringe

Intended use

Continuous and post-surgical bladder urinary drainage

Presentation

Sterile, single-use, box of 10 units

Reference

666016

Longitud

40 cm

Reviews

There are no reviews yet.

Be the first to review “Foley Catheter Silicone-Coated Latex Two-Way Tiemann Tip | Balloon 30 ml | CH 16 (16 Fr) | Length 40 cm | Sterile | Ref. 666016”

Your email address will not be published. Required fields are marked *