Description
CH 24 silicone-coated latex Foley catheter for professional urinary drainage
The silicone-coated latex two-way Nelaton Foley catheter with PVC valve is a single-use retention urethral catheter, made of medical-grade latex with a silicone coating. With CH 24 gauge, 5-10 ml balloon and 40 cm length, it is designed to ensure effective, safe and comfortable urinary drainage in adult patients during medical, surgical and post-surgical procedures. A reliable and cost-effective solution for hospitals, clinics, social healthcare centres and healthcare professionals who need a constant and approved supply.
Technical explanation of the device
The Foley catheter is a retention urinary catheter that is inserted through the urethra into the bladder. This two-way version integrates two independent channels in the same body: a main drainage channel through which urine flows into the collection bag and a secondary inflation channel connected to the retention balloon. Once placed, the balloon is filled with sterile water or saline (5-10 ml), anchoring the catheter inside the bladder and preventing accidental displacement during treatment or postoperative recovery.
The straight Nelaton tip, with lateral drainage eyes, facilitates linear and atraumatic insertion, while the silicone coating on the latex reduces friction on the urethral mucosa, minimises the risk of irritation and encrustation and promotes tolerance in short- and medium-term catheterisations. The CH 24 (24 Fr) gauge offers a wide drainage flow rate, ideal when a generous evacuation flow is required, such as in haematuria, urine with sediment or high-flow post-surgical drainage.
Technical specifications
| Characteristic | Detail |
| Catheter type | Straight two-way Foley catheter with Nelaton tip |
| Number of ways | 2 (urinary drainage + balloon inflation) |
| Material | Medical-grade latex with silicone coating |
| Gauge | CH 24 (24 Fr / Charrière-French scale) |
| Balloon capacity | 5-10 ml |
| Length | 40 cm |
| Distal end | Straight Nelaton tip, with lateral drainage eyes |
| Connection | PVC valve compatible with Luer-type syringe; connector for urine collection bag |
| Intended use | Continuous and post-surgical bladder urinary drainage in adults |
| Sterility | Sterile, single-use, individually packaged |
| Presentation | Box of 10 units |
| Reference | 662024 |
Range of sizes of the two-way Nelaton series with PVC valve and 5-10 ml balloon (length 40 cm):
| Reference | Gauge | Cuff | Ways |
| 662012 | CH 12 | 5-10 ml | 2 |
| 662014 | CH 14 | 5-10 ml | 2 |
| 662016 | CH 16 | 5-10 ml | 2 |
| 662018 | CH 18 | 5-10 ml | 2 |
| 662020 | CH 20 | 5-10 ml | 2 |
| 662022 | CH 22 | 5-10 ml | 2 |
| 662024 | CH 24 | 5-10 ml | 2 |
| 662026 | CH 26 | 5-10 ml | 2 |
Equivalences and cross-references
By specifications (CH 24 gauge, 5-10 ml balloon, two-way, Nelaton tip and silicone-coated latex), this catheter is comparable and interchangeable with 24 Fr silicone-coated latex Foley catheters from manufacturers such as Rüsch/Teleflex (Rüsch Gold range), Bard (BD group), Coloplast or B. Braun, without the need to modify the placement protocol or connection accessories. The Charrière (CH) scale is directly equivalent to the French (Fr) scale, so CH 24 gauge is interchangeable, always verifying balloon, length and material.
Within the Cahnos catalogue, the same two-way Nelaton configuration with rubber valve corresponds to the 6622xx series (ref. 662224 in CH 24); the version with 30 ml balloon corresponds to the 6630xx series (ref. 663024 in CH 24). If simultaneous bladder irrigation is required, the three-way version may be considered; for patients with latex allergy or medium- and long-term catheterisations, the 100% silicone range is recommended, allowing all bladder drainage cases to be covered with a single supplier.
Selection tips and variants of interest
CH 24 gauge is reserved for adult patients with high flow requirements, urine with sediment, haematuria or high-flow post-surgical drainage. Always select the smallest gauge that ensures adequate drainage under medical criteria, and consider smaller gauges (CH 16-22) in patients with a narrower urethra or less demanding catheterisations.
Inflate the balloon only after confirming correct bladder placement, with the recommended volume of sterile water or saline (5-10 ml), and use compatible water-soluble lubricant and aseptic technique. Connect the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection and check the integrity of the sterile packaging before each use. To complete the drainage system, we recommend combining this catheter with our urine collection bags. Contact our technical-commercial team for special volume purchase conditions for hospitals and purchasing groups.



Reviews
There are no reviews yet.