We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Foley Catheter Silicone-Coated Latex Two-Way Nelaton Tip | PVC Valve | 5-10 ml Balloon | CH 26 (26 Fr) | Length 40 cm | Sterile Urinary Catheter for Adults

9,70 €

Two-way silicone-coated latex Foley catheter, Nelaton tip, gauge CH 26 (26 Fr), 5-10 ml retention balloon and 40 cm length, with PVC valve compatible with Luer-type syringe. Indicated for continuous urinary drainage in adult patients in urology, hospitalisation, surgery and post-surgical care services. The silicone coating reduces friction on the urethral mucosa, facilitates comfortable and atraumatic insertion and promotes tolerance in short- and medium-term catheterisation. Sterile single-use medical device, with standard connector for urine collection bag. Presentation in box of 10 units. Reference 662026.

International shipping. Import duties and taxes are payable by the recipient.

Reference
662026

Description

1. Introduction

The two-way silicone-coated latex Foley catheter with Nelaton tip, CH 26 (26 Fr) gauge and PVC valve is a single-use retention urinary catheter, manufactured from medical-grade latex with a silicone coating. It is indicated for effective, safe and controlled urinary drainage in adult patients, particularly in urology, hospitalisation, surgery, intensive care and post-surgical care services. Its excellent value for money and its silicone-coated design make it a reliable and economical solution for hospitals, clinics, social healthcare centres and healthcare professionals who require a constant and approved supply.

2. Technical explanation of the device

The Foley catheter is a retention urinary catheter that is inserted through the urethra into the bladder. This two-way version integrates two independent channels in a single body: a main drainage channel through which urine flows into the collection bag and a secondary inflation channel connected to the retention balloon. Once the catheter is in place, the balloon is filled with sterile water or physiological saline (5-10 ml), which anchors the catheter inside the bladder and prevents accidental displacement during treatment or postoperative recovery.

The straight Nelaton-type tip, with lateral drainage holes, facilitates linear and atraumatic insertion, while the silicone coating over the latex reduces friction on the urethral mucosa, minimises the risk of irritation and encrustation and promotes tolerance in short- and medium-term catheterisation. The PVC valve allows the balloon to be inflated with a Luer-type syringe and guarantees a hermetic seal of the system during the indwelling period. The CH 26 (26 Fr) gauge offers a very wide drainage flow rate, ideal when high-flow evacuation is required, such as in severe haematuria, heavily sedimented urine or high-volume postoperative drainage.

3. Technical Specifications

Catheter type Straight two-way Foley catheter with Nelaton tip
Number of ways 2 (urinary drainage + balloon inflation)
Material Medical-grade latex with silicone coating (siliconised latex)
Gauge CH 26 (26 Fr / Charrière-French scale; external diameter approx. 8.7 mm)
Balloon capacity 5-10 ml
Length 40 cm
Distal end Straight Nelaton tip, with lateral drainage eyes
Connection PVC valve compatible with Luer-type syringe; standard connector for urine collection bag
Intended use Continuous and post-surgical bladder urinary drainage in adults
Sterility Sterile, single-use, individually packaged
Presentation Box of 10 units
Reference 662026

Range of gauges in the two-way Nelaton series with PVC valve and 5-10 ml balloon (length 40 cm):

Reference Gauge Cuff Ways
662012 CH 12 5-10 ml 2
662014 CH 14 5-10 ml 2
662016 CH 16 5-10 ml 2
662018 CH 18 5-10 ml 2
662020 CH 20 5-10 ml 2
662022 CH 22 5-10 ml 2
662024 CH 24 5-10 ml 2
662026 CH 26 5-10 ml 2

4. Equivalences and Cross-References

By specifications (CH 26 gauge, 5-10 ml balloon, two-way, Nelaton tip and silicone-coated latex), this catheter is comparable and interchangeable with 26 Fr silicone-coated latex Foley catheters from manufacturers such as Rüsch/Teleflex (Rüsch Gold range), Bard (BD group), Coloplast or B. Braun, without the need to modify the insertion protocol or connection accessories. The Charrière (CH) scale is directly equivalent to the French (Fr) scale, so the CH 26 gauge is interchangeable, always verifying balloon, length, valve and material.

Within the Cahnos catalogue, the same two-way Nelaton configuration with 5-10 ml balloon and rubber valve corresponds to ref. 662226 (CH 26); the version with 30 ml balloon corresponds to the 6630xx series (ref. 663026 in CH 26). If simultaneous bladder irrigation is required, the three-way version (6680xx series, ref. 668026 in CH 26) may be considered; for patients with latex allergy or medium- and long-term catheterisation, the 100% silicone range (ref. 643026) is recommended, which allows all bladder drainage cases to be covered with a single supplier.

5. Selection tips and variants of interest

The CH 26 gauge is reserved for adult patients with very high flow requirements, urine with abundant sediment, haematuria or high-flow postoperative drainage. Always select the smallest gauge that ensures adequate drainage under medical criteria; the intermediate gauges CH 14, CH 16 and CH 18 are the most common in standard adult catheterisation, while CH 24 and CH 26 are reserved for situations of high drainage demand. In the same 6620xx series, gauges from CH 12 to CH 26 are available, all with 5-10 ml balloon and PVC valve. If you need a larger fixation surface and a lower risk of accidental expulsion, consider the 30 ml balloon (6630xx series).

Inflate the balloon only after confirming correct bladder placement, with the recommended volume of sterile water or physiological saline (5-10 ml), and use compatible water-soluble lubricant and aseptic technique. Connect the collection bag with a closed system to minimise the risk of catheter-associated urinary tract infection and check the integrity of the sterile packaging before each use. To complete the drainage system, we recommend combining this catheter with our urine collection bags. Contact our technical-commercial team for special volume purchase conditions for hospitals and purchasing centres.

Additional information

Product type

Straight two-way Foley catheter with Nelaton tip

Material

Medical-grade latex with silicone coating (siliconised latex)

Gauge

CH 26 (26 Fr / Charrière-French scale)

Outer diameter

Approx. 8.7 mm

Balloon capacity

5-10 ml

Number of ways

2 (urinary drainage + balloon inflation)

Valve

PVC valve compatible with Luer-type syringe

Tip

Straight Nelaton type with lateral drainage holes

Connection

Standard connector for urine collection bag

Intended use

Continuous and post-surgical bladder urinary drainage in adults

Sterilisation

Sterile, single-use, individually packaged

Presentation

Box of 10 units

Reference

662026

Longitud

40 cm

Reviews

There are no reviews yet.

Be the first to review “Foley Catheter Silicone-Coated Latex Two-Way Nelaton Tip | PVC Valve | 5-10 ml Balloon | CH 26 (26 Fr) | Length 40 cm | Sterile Urinary Catheter for Adults”

Your email address will not be published. Required fields are marked *