Description
1. Introduction
The two-way Foley bladder catheter (reference 22058, SKU GM22058) is a single-use medical device, manufactured in 100% latex coated with silicone to facilitate insertion and minimise irritation of the urethral mucosa. Its CH/FR 20 gauge places it among the larger diameters in the range, designed for high drainage flow rates in adult patients. It is supplied in a box of 10 units, a practical presentation for urology departments, operating theatres, hospital wards and social healthcare centres. For large orders you can request a quote: request your personalised offer from our sales team.
2. Technical Explanation
The two-way Foley catheter (two-way) has two channels: one for draining urine from the bladder into the collection bag and another for inflating the retention balloon, which holds the catheter in position once inserted into the bladder. Manufactured in natural latex with a 100% internal and external silicone coating, it offers a smooth surface that reduces friction during insertion and the risk of encrustation. It incorporates a rigid valve (hard valve) for inflating the balloon and a distal drainage eye. The indication “balloon 5-10 ml” means that the balloon can be inflated with a volume between 5 ml and 10 ml, depending on clinical criteria and retention needs. Its total length is 40 cm. It is a sterile single-use device, ready to use, supplied with packaging and a multilingual instruction manual.
3. Technical Specifications
Main features of the catheter
| Characteristic | Specification |
|---|---|
| Catheter type | Two-way Foley (two-way) |
| Material | 100% silicone-coated latex |
| Gauge | CH/FR 20 |
| Retention balloon | 5-10 ml (the balloon can measure between 5 ml and 10 ml) |
| Length | 40 cm |
| Valve | Rigid (hard valve) |
| Number of ways | 2 (drainage and balloon) |
| Use | Sterile, single-use (single use) |
| Presentation | Box of 10 units |
Product data
| Field | Value |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 22058 |
| Sales unit | Box of 10 pcs |
| Device type | Medical device (medical device) |
| Device class | II A |
| CND | U010201 |
| EAN | 8023279220582 |
| Packaging and multilingual manual | GB, FR, IT, ES, PT, DE, NL, PL, CZ, SK, HU, EE, LT, LV, DK, SE, FI, RO, BG, GR, HR, SI |
Available references within the same range (balloon 5-10 ml, box of 10 units)
| Gauge | Balloon | Reference | SKU Cahnos | Presentation |
|---|---|---|---|---|
| CH/FR 12 | 5-10 ml | 22054 | GM22054 | Box of 10 units |
| CH/FR 14 | 5-10 ml | 22055 | GM22055 | Box of 10 units |
| CH/FR 16 | 5-10 ml | 22056 | GM22056 | Box of 10 units |
| CH/FR 18 | 5-10 ml | 22057 | GM22057 | Box of 10 units |
| CH/FR 20 | 5-10 ml | 22058 | GM22058 | Box of 10 units |
| CH/FR 22 | 5-10 ml | 22059 | GM22059 | Box of 10 units |
There is also a variant of the same family with a 30 ml retention balloon and supplied in a box of 50 units, available in larger gauges (references 22064 to 22070).
4. Equivalences and Cross-References
This item corresponds to reference 22058 (SKU GM22058) and belongs to the range of two-way silicone-coated latex Foley catheters. As a variant of the same CH/FR 20 gauge with a 30 ml retention balloon and supplied in a box of 50 units, the corresponding reference from the Ref. 22064 to 22070 series is available. No official 1:1 equivalences with other manufacturers have been identified from reliable sources for this reference; two-way silicone-coated latex Foley catheters of 20 Fr gauge with a 5-10 ml balloon from other brands (Rüsch/Teleflex, Bard, Coloplast, B. Braun, etc.) are comparable by category, but the balloon, length, material and device class must always be verified before any substitution in tenders. Consult our technical-commercial team if you need to check substitutions.
5. Selection tips and variants of interest
The choice of gauge and balloon volume should be based on the clinical assessment of the healthcare professional. The CH/FR 20 gauge is usually reserved for adult patients requiring a high drainage flow rate or when a smaller gauge is insufficient. For short-duration procedures or reduced stays, the variants with a 5-10 ml balloon from this same series are suitable; for prolonged catheterisation requiring firmer fixation, consider the versions with a 30 ml balloon from the same family. Before each use, check the integrity of the sterile packaging and inflate the balloon with the indicated volume only after confirming correct bladder placement; always deflate before removal. To complete the closed system, a urinary drainage bag, catheter fixation device and aseptic technique are recommended. Consult your nursing or urology department to confirm the gauge, balloon volume and type of material according to your centre’s protocol. Contact our team for availability and quotes for the different references in the range.




Reviews