Description
1. Commercial Introduction
The precordial suction electrode FIAB Ref. F9016SSC is the reference reusable solution for resting ECG recording and cardiac monitoring in adult patients. Its metallic ring of Ø 30 mm and its SSC silver/silver chloride (Ag/AgCl) sensor ensure stable electrical contact and clean tracings, even during prolonged recordings.
It is the ideal choice for cardiology clinics, emergency departments, occupational medicine units, diagnostic centres and hospitals that need to replenish the supply of chest electrodes for their electrocardiographs and monitors, with guarantees of durability, hygiene and cost-effectiveness through multiple uses. It is sold on quotation, in full boxes.
2. Technical explanation of the electrode
This suction electrode is placed on the patient’s precordial surface and is fixed by the vacuum generated by the bulb, without the need for adhesives or tapes. The metallic ring provides firm and reproducible contact on the chest, facilitating rapid repositioning between patients, a common circumstance in daily electrocardiography practice.
The SSC sensor (silver/silver chloride, Ag/AgCl) offers a stable electrode potential and very low polarisation, which reduces baseline drift and interference, improving the reproducibility of the ECG signal. The universal connection allows coupling to most patient cables and electrocardiographs on the market (depending on the cable terminal), and as it is a reusable electrode, follow the manufacturer’s cleaning and disinfection instructions to extend its service life.
3. Technical Specifications
Data verified against the manufacturer’s official catalogue FIAB (fiab.it, section ECG > Reusable Electrodes > Suction Chests > With Metallic Ring).
| Characteristic | Value |
|---|---|
| Reference FIAB | F9016SSC |
| Electrode size | Ø 30 mm |
| Packaging | 6 units |
| Units per box (web) | 6 |
| Product type | Reusable precordial suction electrode with metallic ring |
| Sensor | SSC (silver/silver chloride, Ag/AgCl) |
| Fixation mechanism | Vacuum suction cup (adhesive-free) |
| Connection | Universal |
| Application | Resting ECG and cardiac monitoring |
| Use | Reusable |
| Brand | FIAB |
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Sale | On quotation, in complete boxes |
4. Equivalences and Cross-References
The reference F9016SSC corresponds to the official catalogue code FIAB for the precordial suction electrode with metallic ring of Ø 30 mm and SSC sensor. No reliable sources have been found for a manufacturer-validated equivalence table that cross-references this code 1:1 with third-party codes, so no direct equivalents are indicated without technical verification.
Within the FIAB suction electrode family itself, the reference F9003SSC corresponds to the comparable version of Ø 30 mm with rubber ring and SSC sensor, with the same diameter, sensor and presentation, but with a different overall geometry. The Cahnos SKU 0590030 corresponds to a thoracic suction cup electrode Ag/AgCl of Ø 30 mm, comparable by category. On the market there are other homologous families of thoracic suction electrodes of Ø 30 mm with Ag/AgCl sensor that can serve as a comparison in tenders, but they must be verified against the issuing manufacturer and the centre’s patient cable before any substitution.
5. Selection tips and variants of interest
The Ø 30 mm diameter is the recommended size for adult patients and medium-to-large chests, where a larger capture surface is required for a robust signal. For other needs within the same FIAB suction electrode family, versions with rubber ring or other diameters are available; consult our technical-commercial department to confirm the most suitable variant for your clinical practice.
Before placing the order, check the terminal of the patient cable of your electrocardiograph or monitor: this reference offers universal connection, covering most equipment on the market; if your cable has a different terminal, consult our department to confirm the appropriate adapter. To complete the service provision, combine this precordial electrode with peripheral limb electrodes and the unipolar cables and leads from the same range.
Given its reusable nature, always follow the manufacturer’s cleaning and disinfection instructions and periodically check the condition of the sensor to maintain optimal signal quality and extend the electrode’s service life. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial team to confirm compatibility, exact reference and formal quotation.





Reviews