Description
1. Commercial Introduction
We offer the SpO2 pulse oximeter sensor for adult patients, digital clip type, designed for use with monitors in the Datex-Ohmeda family. It is the perfect replacement solution for medical electronics services, hospitals, clinics and maintenance contracts that need to restore oxygen saturation monitoring quickly and reliably, while keeping equipment already installed on wards, in the ICU, operating theatre and emergency departments operational.
It is a reusable clip-type sensor for an adult finger, supplied by the manufacturer with a multilingual instruction manual (GB, FR, IT, ES). For large orders you can request a quote: ask our technical-commercial team about terms and availability.
2. Technical explanation of the equipment and the sensor
Pulse oximetry is a non-invasive technique that measures the functional oxygen saturation of arterial haemoglobin (SpO2) and pulse rate by spectrophotometry: the sensor emits light at red and infrared wavelengths through the vascular bed of the finger and detects differential absorption according to the degree of blood oxygenation. The signal is transmitted to the monitor, which processes it and displays the values on screen.
This sensor is configured as an adult patient finger clip (Adult Finger), with a 0.9 m cable. To connect it to the equipment you need the extension cable with code 35302, as indicated by the manufacturer: the sensors in this SpO2 series are connected to the device via that extension cable. The product is supplied with an instruction manual in GB, FR, IT and ES.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Sensor type | SpO2 pulse oximeter, digital finger clip for adult patient (Adult Finger) |
| Use | Reusable |
| Cable length | 0.9 m |
| Extension cable required | Code 35302 (sold separately) |
| Documentation | Instruction manual in GB, FR, IT, ES |
| Sales unit | 1 unit |
Available references
| Reference | Length | Sales unit |
|---|---|---|
| GM35232 | 0.9 m cable | 1 unit |
| GM35234 | 3.0 m cable | 1 unit |
Product data
| Compatible brand | Datex-Ohmeda |
|---|---|
| Manufacturer | GIMA |
| Sales unit | 1 unit |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
Compatibility (according to the manufacturer’s catalogue)
Datex-Ohmeda: AS/3, CS/3, CH/S, CH/2S, CH-RS, SAF-F, CG/2S, Cardiocap I, Cardiocap II, Cardiocap 5, Capnomac Ultima, Light Monitor, M-Estpr, Oscar II, OSP-200, Satlite Trans, Satlite, Trans Plus, System 5, ULT500.
4. Equivalences and Cross-References
This sensor corresponds to the manufacturer’s references 35232 (0.9 m cable) and 35234 (3.0 m cable), marketed by Cahnos with the GM prefix (SKU GM35232-F for the 0.9 m variant). To connect to the device, the extension cable code 35302 is required, which must be ordered as an additional accessory.
Datex-Ohmeda (now part of the GE Healthcare family) does not publish an official cross-reference table for these third-party sensors; the compatibility indicated comes from the distributor manufacturer’s own catalogue (Product_DB.csv) and is classified as compatible according to the manufacturer’s official list. No equivalences with other manufacturers are given here as no reliable verified sources are available; before any replacement, always verify the exact monitor model and the type of connector/extension cable required.
5. Selection tips and variants of interest
- Choose the cable length according to your installation: reference GM35232 has a 0.9 m cable; if your monitor is far from the connection point or the patient is mobilised, consider the GM35234 variant with a 3.0 m cable.
- Do not forget the extension cable (code 35302): this SpO2 sensor needs the extension cable to connect to the device; order it together with the sensor to complete the set.
- Verify the monitor model: check in the compatibility list (AS/3, CS/3, Cardiocap, Capnomac, System 5, etc.) that your equipment is included before placing the order.
- For monitor fleets and tenders: ask our technical-commercial team for special volume terms, product documentation and confirmation of compatibility with your specific model.





Reviews