Disposable pre-wired paediatric and neonatal ECG electrode of non-woven fabric (NWF) 20×15 mm, 50 cm cable and 1.5 mm DIN connector, radiotransparent, SSC sensor – FIAB Ref. F9057PRRM · Box of 150 units

Price on request

ECG electrode disposable and pre-wired from FIAB, specifically designed for electrocardiographic monitoring of paediatric and neonatal patients. Its oval body made of non-woven fabric (NWF), 20×15 mm, with SSC sensor (Ag/AgCl) and solid gel, provides a stable and comfortable recording on the delicate skin of the newborn. It incorporates a 50 cm cable and a 1.5 mm female connector (DIN 42802), compatible with lead wires from European-standard monitors. Its radiotransparent construction allows monitoring to be maintained during X-rays and imaging tests without artefacts. Presentation in bags of 3 units; box of 150 units for hospital supply. Latex-free, single-use.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F9057PRRM
Brand
FIAB

Description

1. Commercial Introduction

The ECG electrode F9057PRRM by FIAB is a disposable, pre-wired consumable designed for continuous monitoring of paediatric and neonatal patients in intensive care units (ICU/NICU), neonatology, incubators, neonatal transport and paediatric clinics. Its compact oval format of 20×15 mm in non-woven fabric (TNT) reduces the adhesion surface on the immature skin of the newborn and minimises skin lesions, while its radiolucent nature allows the electrodes to remain in place during X-rays and other imaging tests without interference in the recording. It is supplied in bags of 3 units, with a box of 150 units adapted to the regular consumption of hospital services. Product without public price: sale on quotation.

2. Technical Explanation

The electrode acts as an interface between the patient’s skin and the bedside monitor: the non-woven fabric (TNT) backing with medical-grade adhesive ensures a gentle but firm fixation, while the SSC sensor element on solid low-impedance gel guarantees stable signal transmission for a clean, continuous ECG trace. The integrated 50 cm cable terminates in a 1.5 mm female connector, commercially known as a DIN safety connector (DIN 42802), compatible with most ECG monitor lead wires with European standard. Its radiolucent (radiotransparent) condition allows monitoring to continue during X-rays, fluoroscopy and other imaging examinations without generating artefacts or interruptions, an essential aspect when the neonatal patient requires continuous cardiac monitoring during the examination. It is a single-use and latex-free product: it must be discarded after each patient and the expiry date of the packaging must be respected so as not to compromise the conductivity of the adhesive or the gel.

3. Technical Specifications

Characteristic Value
Reference FIAB F9057PRRM
Electrode size 20×15 mm
Packaging 150 units (50 bags of 3 units)
Units per box (web) 150
Parameter Specification
Product type Disposable, pre-wired ECG electrode
Clinical use Paediatrics and neonatology (ECG monitoring)
Adhesive body shape Oval, 20×15 mm
Support Non-woven fabric (TNT / non woven)
Sensor SSC (Ag/AgCl) on low-impedance solid gel
Cable 50 cm, pre-wired
Connection Female socket 1.5 mm (DIN 42802)
Radiotransparency Yes, suitable for radiography and imaging examinations (plain film / X-ray)
Material Non-woven fabric backing, radiotransparent material
Use Single-use (disposable), latex-free
Presentation Bags of 3 units
Minimum sales unit Box of 150 units
Manufacturer FIAB SpA (Vicchio, Florence, Italy)

Note: the reference data, size, connection and presentation are copied literally from the manufacturer’s official catalogue; confirm with the technical data sheet of the supplied batch. Radiotransparency refers to use with planar imaging (X-rays): verify in the equipment manual compatibility in magnetic resonance imaging before use in MRI.

4. Equivalences and Cross-References

This reference belongs to the category of pre-wired, radiolucent neonatal monitoring electrodes with 1.5 mm DIN connector. The cross-references shown are comparable by category (not 1:1 interchangeable): the backing material, size, connector type and monitor lead wire must be checked one by one before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
FIAB Group Pre-wired radiotransparent neonatal series of non-woven fabric F9057PRRM / F9057NQ/RM/50 (also F9057NRM and F9057NQ/RM/AAMI) Variants of the same family (not interchangeable 1:1) Codes confirmed in the manufacturer’s official catalogue: oval formats 20×15 mm, 23×30 mm or square 22×22 mm, cable 50-60 cm, 1.5 mm DIN connector, SSC sensor, non-woven backing and radiolucent. Verify geometry and cable length.
FIAB Group Pre-wired radiotransparent neonatal foam series, oval format 23×30 mm F9058NRM (F9058N/60 with 60 cm cable) Comparable by category (not interchangeable 1:1) Code confirmed in the manufacturer’s official catalogue: foam backing versus non-woven fabric, 23×30 mm, SSC sensor, 1.5 mm DIN connector, radiolucent and neonatal.
3M / Solventum (Red Dot™) Series 2200, pre-wired radiolucent neonatal electrode, soft cloth 22×22 mm 2282 / 2282L Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and public sources: soft cloth backing, surface 22×22 mm, pre-wired radiolucent cable with 1.5 mm DIN connector. Verify connector and monitor lead wire.
Cardinal Health (Kendall™) KittyCat™ Cloth Pre-Wired, neonatal radiolucent 1051NPSM / 31424743 Comparable by category (not interchangeable 1:1) Code confirmed in GUDID and distribution catalogue: cloth, cable ~60 cm, safety connector ≈1.5 mm DIN, radiolucent, in strips of 3 units. Verify connector.
Halbach Medical Clinical ECG Electrode P22DR (neonatal) EC849923 Comparable by category (not interchangeable 1:1) Code confirmed in the manufacturer’s official catalogue: non-woven cloth backing, 1.5 mm DIN connector, hydrogel, radiolucent and repositionable; declared comparable to Red Dot 2282/2269 and Kendall 1051NPSM.

There is no equivalence table validated by the manufacturer that authorises the direct substitution of original electrodes with third-party patches: the connector, lead wire and patch size are specific to each monitoring platform. Any substitution must be validated against the technical data sheet and instructions for use of the monitor and the electrode; consult with the technical department of Cahnos before use in tenders.

5. Selection tips and variants of interest

Verify the connector type of your monitor: this reference uses a 1.5 mm connection (DIN 42802 connector). If your lead wire uses a 4 mm connector, request the variants of the same FIAB family pre-wired with a 4 mm socket (e.g. the foam series with 4 mm socket, cables of 35 or 80 cm depending on reference), or the appropriate adapters. Both formats are not interchangeable with each other without the corresponding adapter.

Choose the size according to the thoracic surface: the oval format of 20×15 mm in this data sheet is the smallest in the family, recommended for very low birth weight neonates, extreme premature infants and very limited adhesion areas. If the patient has a larger thoracic surface, the same FIAB family offers larger formats (e.g. oval 23×30 mm or square 22×22 mm) with the same connection type and backing.

Radiotransparency: if the patient may require X-ray or imaging control during monitoring, this version avoids artefacts without removing the electrode. Radiotransparency is intended for planar imaging (X-rays); verify in the equipment manual compatibility in magnetic resonance imaging.

Backing material: non-woven fabric (TNT) combines softness and adaptability to the thoracic contour of the neonate. Depending on the preferences of the department, the radiolucent foam series from FIAB (F9058NRM) may be considered, with different geometry and behaviour on the skin.

Single use and storage: disposable single-use product per patient; store in a dry place and respect the expiry date of the packaging so as not to compromise the conductivity of the adhesive or the quality of the gel. For institutional orders, tenders or supply agreements, contact the technical-commercial team of Cahnos to confirm compatibility with your monitor fleet.

Additional information

Brand

FIAB

Electrode size

20×15 mm

Packaging

150 units (50 bags of 3 units)

Manufacturer reference

F9057PRRM

Product type

Disposable pre-wired ECG electrode

Measurements

20×15 mm (oval)

Support

Non-woven fabric (TNT / non woven)

Sensor

SSC (Ag/AgCl) on solid gel

Cable length

50 cm

Connection type

Female socket 1.5 mm (DIN 42802)

Radiotransparency

Yes, suitable for X-ray and imaging examinations

Intended use

Paediatric and neonatal ECG monitoring (ICU, neonatology, incubators)

Presentation

150 units (50 bags of 3 units)

Minimum sales unit

Box of 150 units

Use

Single-use (disposable)

Manufacturer

FIAB SpA (Vicchio, Florence, Italy)

Latex

Latex-free

Reviews