Description
1. Commercial Introduction
Complete or renew the wiring of your electrocardiograph with the ECG patient cable FIAB Ref. F5747RC, a replacement accessory of proven quality manufactured by FIAB SpA (Vicchio, Florence, Italy), one of Europe’s leading specialists in cables and connectivity for electrocardiography. Designed specifically for equipment on the Fukuda Denshi platform, this cable provides stable and reliable signal transmission in daily clinical practice in cardiology clinics, emergency departments, primary care and functional diagnostic centres. Its inspectable distributor is a key advantage: it allows visual checking of the condition of internal connections, facilitating preventive maintenance and extending the service life of the accessory. As this product is supplied on a quotation basis, our technical-commercial team will confirm exact compatibility with your equipment and supply conditions.
2. Technical Explanation
The ECG patient cable is the element in the recording chain that transmits the cardiac electrical signal captured by the electrodes placed on the patient’s chest and limbs to the input of the electrocardiograph or monitor. The quality of the trace depends directly on the condition of the cable: deteriorated insulation, a loose connector or a fatigued flex point are sources of artefacts, interference and signal loss that can compromise the diagnosis.
This model incorporates an inspectable distributor (manifold): the housing that groups the leads can be opened to visually check the condition of the internal connections, conductors and insulation, allowing signs of wear or false contacts to be detected before they affect the quality of the recording. The patient end has snap terminals (press stud, called CLIP by the manufacturer), the most common press-fit attachment system in electrocardiography, which attaches quickly and securely to standard disposable ECG electrodes. The opposite, specific connector attaches to the patient port of Fukuda Denshi devices, ensuring a firm fit and clean traces with minimal interference.
3. Technical Specifications
Specifications verified in the manufacturer’s official catalogue (fiab.it):
| Characteristic | Value |
|---|---|
| Reference FIAB | F5747RC |
| Packaging | 1 unit |
| Units per box (web) | 1 |
| Compatible with | Fukuda Denshi |
Additional catalogue data:
| Parameter | Specification |
|---|---|
| Brand | FIAB |
| Original manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Patient cable for electrocardiography (ECG) |
| Manifold / central connector | Inspectable (openable manifold) |
| Patient connection | Snap / pressure clip (CLIP) |
| Compatibility | Equipment Fukuda Denshi |
| Application | Resting electrocardiography and monitoring |
| Catalogue category FIAB | ECG > Patient Cables > Inspectable Manifold > Snap |
| Presentation | 1 unit |
| Sales unit | On request (sold in complete boxes, per tariff) |
| Available references | Description |
|---|---|
| FIAB-F5747RC | SKU Cahnos / order reference for this product |
| F5747RC | Manufacturer reference FIAB for the same cable |
Technical data according to the manufacturer’s official catalogue FIAB. Measurements, models and references are copied literally; no unconfirmed specifications are included.
4. Equivalences and Cross-References
Reference F5747RC is the original factory code FIAB for this ECG patient cable with inspectable distributor and snap connection compatible with Fukuda Denshi devices, also registered under the distribution SKU Cahnos FIAB-F5747RC: both designations identify the same product unit.
No official equivalence table has been found in reliable sources authorising 1:1 replacement with cables from other manufacturers: ECG patient cables are accessories specific to the equipment-side connector, the number of leads and the electrode attachment system, so any alternative must always be validated against the electrocardiograph’s technical data sheet. Within FIAB’s own catalogue (verified source fiab.it) there are other references in the same family with inspectable distributor and snap connection, such as F5747C (also for Fukuda Denshi), F5252C (Fukuda Denshi), F5748RC and F5749RC (Burdick/Quinton and Siemens), F5746RC (Marquette, Hellige), F5737RC (Cardioline) or F5738RC (Kenz), among others. For the same Fukuda Denshi platform, FIAB offers variants with different electrode terminations: F6252, F6747 and F6747R (4 mm plug) and F6747P / F6747RP (pinch-type forceps). These references share a platform or product family but may differ in connector or terminal configuration, so they should not be considered automatically interchangeable. Consult Cahnos’s technical department before considering alternatives in tenders.
5. Selection tips and variants of interest
Before placing the order, confirm that your electrocardiograph or monitor belongs to the Fukuda Denshi platform and check the terminal type of your electrodes: this reference uses snap connection (press stud / CLIP), suitable for the standard press-fit disposable ECG electrodes on the market. If your electrode stock uses 4 mm plugs or pinch-type forceps, consider the FIAB variants on the same Fukuda Denshi platform (F6252 / F6747 / F6747R or F6747P / F6747RP series), subject to technical validation.
Take advantage of the inspectable distributor by carrying out periodic checks of the condition of the internal connections, snap terminals and cable insulation, especially before diagnostic tests or prolonged recordings. It is recommended to keep a spare cable per electrocardiograph so as not to interrupt clinical activity during maintenance, and to replace the assembly at any sign of deterioration or loss of signal quality. For hospital supplies, equipment fleets or tenders, contact Cahnos’s technical-commercial department to confirm exact compatibility with your equipment fleet and request a tailored quote.