Description
1. Commercial Introduction
The FIAB ECG patient cable Ref. F6749RP is the connection accessory that your cardiology department, clinic or monitoring unit needs to keep its electrocardiographs and equipment compatible with Burdick/Quinton and Siemens systems operational. Manufactured by FIAB SpA (Vicchio, Florence, Italy), a European benchmark in clinical cabling for medical electronics, this cable combines an inspectable manifold with forceps-type terminals, ensuring clean, stable electrocardiographic signal transmission that is easy to maintain in daily use in clinics, emergency departments, hospital wards and diagnostic centres.
2. Technical Explanation
The ECG patient cable is the element in the recording chain that transmits the bioelectrical signal captured by the electrodes placed on the patient’s chest and limbs to the input of the electrocardiograph or monitor. In this model, the leads converge in an inspectable manifold: a central connection box that groups the leads and whose design allows it to be opened to visually check the condition of the internal connections, conductors and insulation, facilitating preventive maintenance and early detection of false contacts or wear before they affect the quality of the trace.
The patient-end termination is of the forceps type (PINCH, the manufacturer’s PINZETTA designation), the classic fastening system that ensures quick, firm and secure attachment to reusable limb and precordial electrodes, with stable contact impedance throughout the recording. The opposite connector is configured for Burdick/Quinton and Siemens devices, ensuring correct fit and clean traces with minimal interference.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F6749RP |
| Packaging | 1 unit |
| Units per box (web) | 1 |
Additional technical data verified in the manufacturer’s catalogue:
| Parameter | Specification |
|---|---|
| Brand | FIAB |
| Manufacturer / original distributor | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Patient cable for electrocardiography (ECG) |
| Lead manifold | Inspectable (openable manifold) |
| Patient connection | Forceps (PINCH / pinzetta) |
| Compatibility | Burdick/Quinton and Siemens devices |
| Catalogue category FIAB | ECG | Patient Cables | Inspectable Manifold | Pinch |
| SKU Cahnos | FIAB-F6749RP |
| Sales unit | On request (no published price) |
4. Equivalences and Cross-References
Reference F6749RP corresponds to the manufacturer FIAB’s original code, verified in the source catalogue (fiab.it, ECG > Patient Cables > Inspectable Manifold > Pinch section), and is marketed by Cahnos under SKU FIAB-F6749RP. No officially validated equivalence table has been found in reliable sources that would allow this reference to be replaced 1:1 by cables from other manufacturers: ECG patient cables are accessories specific to the equipment-side connector, the number of leads and the electrode fastening system, so any alternative must always be validated against the electrocardiograph or monitor’s technical data sheet. Within FIAB’s own catalogue, related references from the same family can be consulted.
| Reference FIAB | Electrode connection | Compatibility | Level |
|---|---|---|---|
| F6749RP | Forceps (PINCH) | Burdick/Quinton, Siemens | Product reference |
| F6748RP | Forceps (PINCH) | Burdick/Quinton, Siemens | Family variant – verify fit |
| F6749R | 4 mm plug (PLUG) | Burdick/Quinton, Siemens | Terminal variant – not interchangeable 1:1 |
| F5749RC / F5748RC | Snap (clip) | Burdick/Quinton, Siemens | Terminal variant – not interchangeable 1:1 |
These references share a platform or product family, but may differ in connector or terminal configuration, so they should not be considered automatically interchangeable. Consult Cahnos’s technical department before proposing alternatives in tenders.
5. Selection tips and variants of interest
Before placing your order, confirm the exact model of your electrocardiograph or monitor and that it corresponds to the Burdick/Quinton or Siemens brands, as well as the fastening system of your electrodes: this reference features a forceps-type connection, suitable for reusable limb and precordial electrodes. If your electrode fleet uses a 4 mm (banana) plug or snap fastener, consider the FIAB variants from the same platform (F6749R for 4 mm plug, F5749RC / F5748RC for snap), after technical validation of the equipment connector.
Take advantage of the inspectable manifold by including periodic checks of the condition of internal connections, forceps terminals and insulation in your preventive maintenance plan: replace the cable at any sign of wear, signal loss or artefacts in the trace. It is recommended to keep a spare unit per electrocardiograph so as not to interrupt clinical activity during maintenance. For complete installations or tenders, contact Cahnos’s technical-commercial department, which will advise you on the appropriate reference for your equipment fleet and provide you with a tailored quotation, as this product is sold on a quotation basis.







Reviews