Description
1. Commercial Introduction
Complete or renew the wiring of your electrocardiographs with the ECG patient cable FIAB Ref. F6250, an original accessory from the Italian manufacturer FIAB SpA (Vicchio, Florence, Italy), a European specialist in electrocardiography accessories. Designed for the Burdick and Quinton platforms, it is the ideal solution for cardiology practices, monitoring services, emergency departments and diagnostic units that need to replace or expand their cable inventory with guarantees of signal quality, durability and easy maintenance.
2. Technical Explanation
The patient cable acts as the transmission path between the electrical signal captured by the electrodes placed on the patient and the electrocardiographic recording equipment. In this reference, the leads converge in an inspectable distributor: a central connection box with an opening lid that groups the lines, protects the connections and allows easy checking or replacement of the connection points without disassembling the assembly. This feature facilitates preventive maintenance, allows early detection of wear, false contacts or loss of insulation, and extends the service life of the cable, ensuring stable contact impedance and clean traces with minimal interference.
At the end of each lead, a 4 mm plug (connector) is fitted, the standard coupling in electrocardiography for chest suction electrodes, limb forceps and tab electrodes. The opposite, specific connector couples to the patient port of Burdick/Quinton devices, ensuring a firm fit and reliable signal transmission throughout the examination.
3. Technical Specifications
Data according to the manufacturer’s official catalogue FIAB (fiab.it, ECG section > Patient cables > Inspectable distributor > 4 mm plug). References and measurements are reproduced literally.
| Characteristic | Value |
|---|---|
| Reference FIAB | F6250 |
| Packaging | 1 unit |
| Units per box (web) | 1 |
| Compatible with | Burdick/Quinton |
| Specification | Technical data |
|---|---|
| Brand | FIAB |
| Original manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Patient cable for electrocardiography (ECG) |
| Distributor | Inspectable (with opening lid) |
| Electrode connection | 4 mm plug (socket) |
| Equipment connection | Specific connector for Burdick/Quinton devices |
| Application | Resting electrocardiography and monitoring |
| Catalogue category FIAB | ECG > Patient cables > Inspectable manifold > 4 mm plug |
| Presentation | 1 unit |
| Available references | Description |
|---|---|
| F6250 / FIAB-F6250 | ECG patient cable with inspectable distributor, 4 mm plug connection, compatible with Burdick/Quinton devices (this product) |
4. Equivalences and Cross-References
Reference F6250 corresponds to the official factory code of FIAB SpA and to the SKU marketed by Cahnos (FIAB-F6250); both identify the same product unit. No official equivalents have been found in reliable sources that authorise 1:1 replacement by cables from other manufacturers: ECG patient cables are specific accessories for the connector of each equipment family, so the number of leads, the terminal type and the specific model of the electrocardiograph must always be validated.
Within the FIAB catalogue itself for Burdick/Quinton equipment with inspectable distributor, there are other variants depending on the electrode connection system that may be of interest:
| Reference FIAB | Electrode connection | Compatibility | Related items |
|---|---|---|---|
| F6250 | 4 mm plug | Burdick/Quinton | This product |
| F6251 | 4 mm plug | Burdick/Quinton | Variant of the same terminal type |
| F6250P | Forceps | Burdick/Quinton | Terminal variant |
| F6251P | Forceps | Burdick/Quinton | Terminal variant |
| F5251C | Snap (clip) | Burdick/Quinton | Terminal variant |
Before any replacement in a tender, verify the equipment connector type, lead configuration and electrode connection system with the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
Check the terminal of your electrodes: this reference uses a 4 mm plug (connector), the usual standard for chest suction electrodes, limb forceps and tab electrodes. If your practice uses snap (clip) or forceps electrodes, consider the FIAB variants of the same Burdick/Quinton platform (F5251C, F6250P or F6251P) or the corresponding connection adapters.
Confirm your equipment model: although the reference is indicated for Burdick/Quinton devices, the pin layout and connector assembly on the electrocardiograph side may vary depending on the platform. Consult our technical department for the exact fit with your electrocardiograph or monitor before placing the order.
Maintenance of the inspectable distributor: take advantage of the opening lid to periodically check the condition of the contacts and the continuity of the leads, thus extending the service life of the cable and the quality of the signal. It is recommended to have a spare unit per electrocardiograph to avoid interrupting clinical activity during maintenance.
Institutional purchases: product without reference price, marketed on quotation. For complete installations, tenders or continuous supply contracts, contact the technical-commercial department of Cahnos indicating the model of your Burdick/Quinton fleet and the type of electrode connection used.