Description
1. Introduction
Complete or renew the wiring of your monitoring with this 5-lead ECG patient cable with forceps adapters (reference MEC41.13-5349), manufactured by APK Technology and distributed through medical ECONET GmbH. It is the spare part indicated for the patient monitors M20 and the fetal monitor SMART 9, designed to preserve the quality of electrocardiographic recording in cardiology, obstetrics, primary care, emergency and hospitalisation departments. As this is a product sold on quotation, our technical-commercial team will confirm the exact compatibility with your equipment and the supply conditions.
2. Technical Explanation
The patient cable is the element of the recording chain that connects the electrodes placed on the patient’s chest and limbs to the monitor input, transmitting the electrical signal of the heart with minimal loss and interference. This model features 5 conductors (5-adrig), the configuration indicated for capturing the standard monitoring and recording leads on the M20 and SMART 9 devices, facilitating the detection of arrhythmias and rhythm disturbances with greater precision than 3-lead systems.
The forceps adapters (Klammeradapter) located at the patient end offer a clip connection system: fast, secure and convenient, as they attach directly onto standard forceps electrodes. Their 3-metre length provides the freedom of movement needed to work comfortably around the bed or stretcher, maintaining stable, low-interference signal transmission, along with robust construction that ensures a long service life and reliable results in every recording.
3. Technical Specifications
The manufacturer’s catalogue specifications are detailed below:
| Parameter | Specification |
| Brand | APK Technology |
| Manufacturer / original distributor | APK Technology (via medical ECONET GmbH) |
| Product type | ECG patient cable (EKG Patientenkabel) |
| Number of conductors | 5 wires (5-adrig) |
| Patient connection | Forceps / clip adapters (Klammeradapter) |
| Cable length | 3 m |
| Compatible equipment | M20 (patient monitor), SMART 9 (fetal monitor) |
| ECONET category | Fetal | Accessories |
Available references
| Reference | Description |
| MEC41.13-5349 | SKU Cahnos / order reference for the 5-lead ECG patient cable with forceps adapters, 3 m, for M20 and SMART 9 |
| 41.13-5349 | Article number medical ECONET / manufacturer’s reference APK Technology for the same cable |
Technical data according to the manufacturer’s catalogue (medical ECONET GmbH).
4. Equivalences and Cross-References
This cable corresponds to the factory reference MEC41.13-5349 (also documented as 41.13-5349) from APK Technology, distributed through medical ECONET GmbH, and is intended for the M20 and SMART 9 monitors. No official equivalence table has been found in reliable sources that would allow this reference to be substituted 1:1 by cables from other manufacturers: ECG patient cables are specific accessories for each equipment family, so the number of conductors, the type of terminal (forceps) and the equipment-side connector must always be verified against the monitor’s technical data sheet before adopting an alternative.
Within the same family from APK Technology distributed by medical ECONET, we find similar references that share design and connection system but are not interchangeable with each other without technical verification of the connector and the target equipment:
| Reference | Description |
| MEC41.13-5359 | 5-lead ECG cable with button adapters (Druckknopfadapter), 1.1 m, for PalmCare Duo and M850 |
| MEC41.13-5367 | 10-wire ECG cable with button adapters, 3 m, for the Cardio M-PLUS, M-PRO, M-PC, Cardio M and Cardio E3 series |
| MEC41.13-5368 | 10-wire ECG cable with forceps adapter, 3 m, for the Cardio M-PLUS, M-PRO, M-PC, Cardio M and Cardio E3 series |
| MEC41.13-5372 | 5-lead ECG cable with button adapters, 3 m, for the CT-08S electrocardiograph |
5. Selection tips and variants of interest
First confirm the exact model of your monitor: this reference is indicated for the M20 and SMART 9 devices. Verify the number of conductors required by your equipment (5 in this case) and the type of terminal at the patient end: the forceps adapters (Klammer) are compatible with the common clip/forceps-type ECG electrodes on the market and are not interchangeable with button systems (Druckknopf), so you must choose the variant according to your electrode stock.
It is recommended to have a spare cable per workstation to avoid interrupting clinical activity during cleaning, maintenance or replacement of the wiring. Periodically inspect the condition of the adapters, connectors and cable insulation, and replace the part at any sign of deterioration or loss of signal quality. For volume orders, supplies or tenders, contact the technical-commercial department of Cahnos to confirm exact compatibility and obtain a formal quotation without obligation.