Description
1. Introduction
The ECG patient cable with inspectable manifold and forceps-type connection (Ref. F6738RP) is the connection accessory that your cardiology department needs to obtain clean and reliable electrocardiographic recordings on Kenz equipment. Manufactured by FIAB SpA (Vicchio, Florence, Italy), one of the European specialists in clinical cabling for electrocardiography, this cable ensures stable transmission of the patient’s bioelectrical signal to the electrocardiograph, with a robust design intended for daily use in consulting rooms, emergency departments and hospitalisation.
2. Technical explanation
The patient cable is the element of the recording chain that connects the electrodes placed on the patient to the input of the electrocardiograph. In this reference, the patient end incorporates forceps-type connections, the most common fixation system for reusable ECG electrodes, which ensures rapid coupling and stable electrical contact. The particular feature of this model is its inspectable manifold: the housing of the lead junction point can be opened to visually inspect the internal connections, detect signs of wear and facilitate preventive maintenance tasks, extending the service life of the assembly. The result is an ideal configuration for departments that value traceability and control of the condition of the cabling in equipment with intensive use.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F6738RP |
| Packaging | 1 unit |
| Units per box (web) | 1 |
| Compatible with | Kenz |
Additional catalogue data:
| Parameter | Specification |
|---|---|
| Brand | FIAB |
| Original manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Patient cable for electrocardiography (ECG) |
| Manifold / connector | Inspectable manifold (openable manifold) |
| Patient connection | Forceps (pinchette type) |
| Compatibility | ECG equipment from the brand Kenz |
| Presentation | 1 unit |
4. Equivalences and Cross-References
Reference F6738RP corresponds to the official factory code FIAB of the product, identified in the manufacturer’s catalogue as compatible with Kenz devices. The Cahnos distribution SKU is FIAB-F6738RP, which identifies the same product unit. No official equivalence table published by the manufacturer cross-referencing this reference with codes from other brands has been found in reliable sources: ECG patient cables are specific to the connector and the electrode set of each device, so any replacement with a third-party cable must be verified field by field (connector type, number of leads and exact model of the Kenz electrocardiograph) before adopting an alternative. Consult the technical department of Cahnos to confirm exact compatibility with your equipment.
5. Selection tips and variants of interest
Confirm the exact model of your Kenz electrocardiograph and the required number of leads before placing the order. This cable uses a forceps connection at the patient end, designed for reusable electrodes with forceps fixation; if your practice uses disposable snap or button electrodes, consider the appropriate connection adapter for your electrode set. Take advantage of the possibility to inspect the manifold: periodically check the condition of the internal connections and the insulation, and replace the cable at any sign of deterioration or loss of signal quality.
This product is sold on quotation. For volume orders, complete fittings or tenders, contact the technical-commercial team of Cahnos, who will confirm reference F6738RP and the most suitable variants for your equipment fleet.