We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

ECG adapter from 4 mm banana to clip (snap) for electrodes and patient cables | FIAB · Ref. PG922/4T – Pack of 10 units

Price on request

The adapter FIAB PG922/4T converts the 4 mm female banana socket of your patient cable into a press-stud type snap fitting (snap), allowing quick, firm and tool-free connection of classic button electrodes in ECG, EEG, EMG and electrotherapy. It is supplied in a pack of 10 units and is available in several colours to identify each lead; its press-fit installation ensures a stable mechanical connection and clean signal transmission throughout the recording. Reusable accessory in a controlled clinical environment, latex-free and ideal as a replacement consumable for cardiology, neurophysiology and monitoring departments. Sold on quotation through our technical-commercial department.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-PG922-4T
Brand
FIAB

Description

1. Introduction

The adapter FIAB PG922/4T is the connection accessory that solves the classic compatibility problem between the 4 mm banana terminal of patient cables and press stud (snap) electrodes. One end snaps onto the electrode button and the other accepts the 3–4 mm banana connector of the cable, ensuring a firm mechanical connection and stable signal transmission during electrocardiographic recording.

It is supplied in a pack of 10 units and is available in different colours to identify each lead, making it the ideal reusable spare part for cardiology, monitoring, electroencephalography and electrotherapy departments that work with cable equipment with a 4 mm socket.

2. Technical explanation

The signal chain is as follows: press stud electrode → adapter (snap side) → adapter (4 mm female banana socket) → patient cable (4 mm male banana) → recording equipment. The snap side coupling is achieved by a press-stud mechanism, without the need for tools or threading, and the metal contact offers low resistivity and good corrosion resistance, resulting in constant contact impedance and a clean signal.

Being a reusable element under controlled clinical conditions and latex-free, it is suitable for sensitive patients and allows continued use following the manufacturer’s cleaning and maintenance instructions. The colour coding facilitates the rapid organisation of peripheral and reference leads in multi-channel electrocardiographs.

3. Technical Specifications

Connection adapter from 4 mm banana socket to press-stud type snap fitting (snap), according to the official FIAB catalogue data:

Product data

Characteristic Value
Reference FIAB PG922/4T
Packaging 10 units
Units per box (web) 10

Technical specifications

Parameter Specification
Brand FIAB (FIAB SpA, Vicchio, Florence, Italy)
Product type Adapter from 4 mm plug to press-fit (press stud / snap)
Cable side connection 4 mm female banana socket (accepts 3–4 mm banana connector)
Electrode side connection Press stud (female snap socket)
Applications Resting ECG and monitoring, EEG, EMG and electrotherapy
Use Reusable in a controlled clinical environment
Latex Latex-free

Colour code (FIAB suffixes)

The PG922/4T adapter allows colour identification according to the FIAB code suffix: R=red, N=black, V=green, G=yellow, B=white.

Suffix Colour
R Red
N Black
V Green
G Yellow
B White

4. Equivalences and Cross-References

The reference PG922/4T corresponds to the official factory code of the product (adapter from 4 mm plug to press-fit socket). The same adapter is marketed in the FIAB family as PG922/4KIT, a kit of 10 pieces in colours (6 white, 1 black, 1 red, 1 green and 1 yellow) to identify leads in 10/12-channel recordings.

No equivalence table validated by the manufacturer has been found that cross-references this reference 1:1 with codes from other brands. The following alternatives are comparable by category (not interchangeable without verification) and should be checked against their technical data sheet before substitution:

Manufacturer / Brand Family / Model Code Level Observations
Lessa (Papeles Registrales, S.A.) Banana clip adapter 3–4 mm for press-stud electrodes 99.113.23 Comparable by category Same function and presentation of 10 units; also accepts tab-type electrodes (TAB)
Lessa (Papeles Registrales, S.A.) Clip terminal to 4 mm female connector adapter (colour variants) 99.113.05 / 99.113.06 / 99.113.07 / 99.113.08 / 99.113.09 Comparable by category Each pack of 10 units in a single colour, compared to the colour-specific supply from FIAB
GIMA S.p.A. Banana to press-stud adapters for electrodes with 4 mm SNAP connection 33367 Comparable by category Set of 10 pieces in colours; verify the diameter and finish of the contact

As a market compatibility reference (not manufacturer specification), the 4 mm banana terminal is the standard commonly used by patient cables of ECG equipment from brands such as Aspel, Bionet, Cardioline, Cardioteck, Fukuda Denshi, Nihon Kohden or Burdick/Quinton. Always check the manufacturer’s technical data sheet before any possible substitution.

5. Selection tips and variants of interest

  • Check your cable connector: this adapter is designed for 4 mm banana sockets; if your cable ends in a 2 mm plug, the variant of the same family for press studs is reference PG922/2T.
  • Identify the leads by colour: request the desired colour with the FIAB suffix (R red, N black, V green, G yellow, B white); for complete 10/12-channel sets, the coloured PG922/4KIT kit speeds up identification.
  • Tab electrodes (TAB): if you use tab-type electrodes instead of press studs, use a crocodile clip adapter (reference F9019) or the dual clip F9017W; a press stud and a tab are not interchangeable without the appropriate adapter.
  • Use and storage: store in a dry place respecting the packaging conditions; no special handling conditions are required and it can be reused in a controlled clinical environment after cleaning as indicated by the manufacturer.
  • Institutional purchases: product sold on quotation. For volume orders, complete sets or tenders, contact our technical-commercial department at Cahnos, indicating the model of your equipment fleet and the type of electrode used.

Additional information

Brand

FIAB

Packaging

10 units

Manufacturer reference

PG922/4T

Manufacturer

FIAB SpA (Vicchio, Florence, Italy)

Product type

ECG connection adapter from 4 mm banana socket to press stud (snap)

Cable side connection

4 mm female banana socket (accepts 3–4 mm banana connector)

Electrode side connection

Press stud (snap)

Available colours

Suffix FIAB: R=red, N=black, V=green, G=yellow, B=white

Presentation

Pack of 10 units

Units per box

10

Application

Resting ECG and monitoring, EEG, EMG and electrotherapy

Latex

Latex-free

Use

Reusable in a controlled clinical environment

Reviews

There are no reviews yet.

Be the first to review “ECG adapter from 4 mm banana to clip (snap) for electrodes and patient cables | FIAB · Ref. PG922/4T – Pack of 10 units”

Your email address will not be published. Required fields are marked *