Description
1. Introduction
The adapter FIAB PG922/4T is the connection accessory that solves the classic compatibility problem between the 4 mm banana terminal of patient cables and press stud (snap) electrodes. One end snaps onto the electrode button and the other accepts the 3–4 mm banana connector of the cable, ensuring a firm mechanical connection and stable signal transmission during electrocardiographic recording.
It is supplied in a pack of 10 units and is available in different colours to identify each lead, making it the ideal reusable spare part for cardiology, monitoring, electroencephalography and electrotherapy departments that work with cable equipment with a 4 mm socket.
2. Technical explanation
The signal chain is as follows: press stud electrode → adapter (snap side) → adapter (4 mm female banana socket) → patient cable (4 mm male banana) → recording equipment. The snap side coupling is achieved by a press-stud mechanism, without the need for tools or threading, and the metal contact offers low resistivity and good corrosion resistance, resulting in constant contact impedance and a clean signal.
Being a reusable element under controlled clinical conditions and latex-free, it is suitable for sensitive patients and allows continued use following the manufacturer’s cleaning and maintenance instructions. The colour coding facilitates the rapid organisation of peripheral and reference leads in multi-channel electrocardiographs.
3. Technical Specifications
Connection adapter from 4 mm banana socket to press-stud type snap fitting (snap), according to the official FIAB catalogue data:
Product data
| Characteristic | Value |
|---|---|
| Reference FIAB | PG922/4T |
| Packaging | 10 units |
| Units per box (web) | 10 |
Technical specifications
| Parameter | Specification |
|---|---|
| Brand | FIAB (FIAB SpA, Vicchio, Florence, Italy) |
| Product type | Adapter from 4 mm plug to press-fit (press stud / snap) |
| Cable side connection | 4 mm female banana socket (accepts 3–4 mm banana connector) |
| Electrode side connection | Press stud (female snap socket) |
| Applications | Resting ECG and monitoring, EEG, EMG and electrotherapy |
| Use | Reusable in a controlled clinical environment |
| Latex | Latex-free |
Colour code (FIAB suffixes)
The PG922/4T adapter allows colour identification according to the FIAB code suffix: R=red, N=black, V=green, G=yellow, B=white.
| Suffix | Colour |
|---|---|
| R | Red |
| N | Black |
| V | Green |
| G | Yellow |
| B | White |
4. Equivalences and Cross-References
The reference PG922/4T corresponds to the official factory code of the product (adapter from 4 mm plug to press-fit socket). The same adapter is marketed in the FIAB family as PG922/4KIT, a kit of 10 pieces in colours (6 white, 1 black, 1 red, 1 green and 1 yellow) to identify leads in 10/12-channel recordings.
No equivalence table validated by the manufacturer has been found that cross-references this reference 1:1 with codes from other brands. The following alternatives are comparable by category (not interchangeable without verification) and should be checked against their technical data sheet before substitution:
| Manufacturer / Brand | Family / Model | Code | Level | Observations |
|---|---|---|---|---|
| Lessa (Papeles Registrales, S.A.) | Banana clip adapter 3–4 mm for press-stud electrodes | 99.113.23 | Comparable by category | Same function and presentation of 10 units; also accepts tab-type electrodes (TAB) |
| Lessa (Papeles Registrales, S.A.) | Clip terminal to 4 mm female connector adapter (colour variants) | 99.113.05 / 99.113.06 / 99.113.07 / 99.113.08 / 99.113.09 | Comparable by category | Each pack of 10 units in a single colour, compared to the colour-specific supply from FIAB |
| GIMA S.p.A. | Banana to press-stud adapters for electrodes with 4 mm SNAP connection | 33367 | Comparable by category | Set of 10 pieces in colours; verify the diameter and finish of the contact |
As a market compatibility reference (not manufacturer specification), the 4 mm banana terminal is the standard commonly used by patient cables of ECG equipment from brands such as Aspel, Bionet, Cardioline, Cardioteck, Fukuda Denshi, Nihon Kohden or Burdick/Quinton. Always check the manufacturer’s technical data sheet before any possible substitution.
5. Selection tips and variants of interest
- Check your cable connector: this adapter is designed for 4 mm banana sockets; if your cable ends in a 2 mm plug, the variant of the same family for press studs is reference PG922/2T.
- Identify the leads by colour: request the desired colour with the FIAB suffix (R red, N black, V green, G yellow, B white); for complete 10/12-channel sets, the coloured PG922/4KIT kit speeds up identification.
- Tab electrodes (TAB): if you use tab-type electrodes instead of press studs, use a crocodile clip adapter (reference F9019) or the dual clip F9017W; a press stud and a tab are not interchangeable without the appropriate adapter.
- Use and storage: store in a dry place respecting the packaging conditions; no special handling conditions are required and it can be reused in a controlled clinical environment after cleaning as indicated by the manufacturer.
- Institutional purchases: product sold on quotation. For volume orders, complete sets or tenders, contact our technical-commercial department at Cahnos, indicating the model of your equipment fleet and the type of electrode used.





Reviews