How to choose a pressure-relieving mattress
8 products in the catalogue
A pressure-relieving mattress is a resting surface for a bed that is placed over the bed base and that comes in very different configurations: foam or polyurethane cores, water surfaces and sets of air cells that are supplied with a compressor or pump. In healthcare and long-term care settings it is used as the resting surface of the bed.
As the choice of a particular surface is a matter for the clinical team, this guide is limited to the purchasing criteria that can be checked in the description of each reference: weight capacity, material, dimensions, presentation as a kit or single unit and medical device status. With those details, references of similar appearance can be compared and ordering errors avoided, such as buying a mattress that does not fit the bed or that does not include the air equipment.
Other related families
Products in this guide
- 135 kg 2
- 140 kg 2
- 150 kg 1
- 200 kg 1
- PVC 2
- Foam 1
- Polyurethane 1
- Kit 4
- Unit 4
- Medical device 7
- Non-medical 1
-

DAMA pressure-relieving mattress of expanded polyurethane foam 195 x 85 x 14 cm | Autoclavable at 135 °C | Ref. 27692
173,85 € In stockAdd to basket -

Pressure-relieving water mattress with air frame – PVC 0.40 mm, 3 water elements – 200 x 93 x 11.5 cm – Ref. 28502 (SKU GM28502)
46,55 € In stockAdd to basket -

Pressure-relieving air bubble mattress – 130 PVC cells 7 cm, 200 x 90 x 7 cm, max. load 135 kg, stage I | Ref. 28564 (SKU GM28564)
19,95 € In stockAdd to basket -

Pressure-relieving air bubble mattress kit with silent compressor – 130 PVC cells of 7 cm, 200 x 90 x 7 cm, load capacity 135 kg, stage I | Ref. 28566 (28564+28565)
49,40 € In stockAdd to basket -

Pressure-relieving mattress with interchangeable cells – 20+1 Nylon+PVC cells, 200 x 86 x 9.5 cm, load 140 kg, stages I-II | Ref. 28567 (SKU GM28567)
92,15 € In stockAdd to basket -

Pressure-relieving mattress kit with interchangeable cells + compressor – 20+1 Nylon+PVC cells, 200 x 86 x 9.5 cm, load 140 kg, stages I-II | Ref. 28569 (SKU GM28569)
125,40 € In stockAdd to basket -

Alternating pressure relief mattress kit 198 x 86 x 12.8 cm with air pump – 17+1 nylon PVC cells, weight capacity 150 kg, stages I-III | MODEL 5010E, Ref. 28575 (SKU GM28575)
218,50 € On orderAdd to basket -

Alternating-pressure pressure-relieving mattress kit 200 x 86 x 21 cm with multimode pump – 20+1 TPU nylon cells, 200 kg load, intensive care | Ref. 28582 (SKU GM28582)
560,50 € In stock🚚 Bulky deliveryAdd to basket
Buying and selection tips
-
Maximum weight capacity
Weight capacity is the detail that rules out references fastest: the range includes mattresses of 135 kg, 140 kg, 150 kg, 160 kg and 200 kg. It is advisable to first fix the expected weight and then check that the description declares an equal or higher capacity. It should not be confused with the weight of the item itself, which is stated separately.
-
Material of the core or cells
The material affects weight, handling and maintenance: the range includes PVC, foam and polyurethane, as well as nylon cells with PVC or with TPU. Check that the declared material suits the department's conditions and follow the manufacturer's instructions for its maintenance.
-
Presentation: kit or single unit
Some references are sold as a kit and others as a single unit. The kit includes the air equipment, compressor or pump, together with the mattress, whereas the single unit is supplied on its own. Before deciding, check whether compatible equipment is already available.
-
External dimensions and height
The external dimensions and height determine the fit on the bed: some references measure 200 x 90 x 7 cm, 200 x 86 x 9.5 cm, 198 x 86 x 12.8 cm or 200 x 86 x 21 cm. Measure the available space and bear in mind that the height varies greatly from one reference to another.
-
Medical device status
Not all references declare the same status. If the purchase must meet medical device status, this must be expressly stated in the item description.
-
Number and material of the cells
In air sets, the cell count and their material allow references of similar appearance to be compared: some have 130 cells, others 20+1 or 17+1, in PVC, nylon+PVC or nylon TPU. Note both details before comparing models.
Frequently asked questions
What is the difference between buying the mattress as a kit and buying it as a single unit?
The kit includes the mattress together with the air equipment, compressor or pump; the single unit is supplied without that equipment. If compatible equipment is already available, the single unit may be enough; if not, the complete set must be allowed for.
How do I check whether a reference supports the expected weight?
Each data sheet declares a maximum weight capacity, which in the range goes from 135 kg to 200 kg. That figure is independent of the weight of the mattress itself, which is stated separately.
Which material should I choose among PVC, foam and polyurethane?
It depends on the department's conditions: PVC appears in air cell sets, whereas foam and polyurethane are associated with solid cores. Check the declared material in the description and the manufacturer's instructions.
Do the external dimensions of the mattress have to match those of the bed?
Yes. There are references of 200 x 90 x 7 cm, 200 x 86 x 9.5 cm or 200 x 86 x 21 cm, and the height varies by model. It is advisable to measure the bed space before deciding.
How do I compare two air cell sets of the same size?
By the number of cells (130, 20+1 or 17+1), the cell material (PVC, nylon+PVC or nylon TPU) and the declared weight capacity. With those three details, references of very similar appearance can be ranked.
Common questions
Confusing the weight capacity with the weight of the mattress
They are two different figures: the maximum weight capacity is the weight the surface supports, and the product weight is that of the item itself. The same data sheet may show 135 kg maximum load and 2.3 kg mattress weight.
Assuming that all references are medical devices
Not all declare it. If the purchase requires that status, it must be verified in the description and not assumed from the name of the item.
Believing that the kit and the single unit are the same item
The kit adds the air equipment to the mattress; the single unit is sold on its own. The same mattress may appear in both presentations, so check the contents before comparing references.





