A pressure syringe for contrast media is the disposable component fitted to an automatic injector, mainly in magnetic resonance imaging and also in computed tomography. It is designed to withstand the pressure generated by the injector. It is supplied as a loose syringe, as a replacement plunger or as a kit of one or two syringes with their tubing.

Some MRI kits consist of one or two syringes, a short or long nozzle, a rapid-fill tube and a coiled low-pressure Y connecting tube of 250 cm with a connector. Capacities range from 60 ml to 200 ml, and the specification is expressed by the volume of each barrel: for example 60/60, 65/65, 65/115 or 100/100 ml in two-syringe kits, and 130 ml or 200 ml in single-syringe ones. The choice is not decided by volume alone: each kit is associated with a specific injector model, and the nozzle, the plunger attachment and the type of connection must match the equipment installed in the room. Before ordering, fix the injector, the volume per barrel and the presentation.

  • High-Pressure MRI Syringe Kit 100301 – 2 Syringes of 65 ml Compatible with MEDRAD Spectris Injector
  • High-Pressure Syringe Kit for MRI Ref. 100302 – Compatible with Spectris Solaris EP (Medrad/Bayer) Injector, 65 ml + 115 ml with 250 cm Coiled Connection
  • High Pressure Syringe for Magnetic Resonance Imaging OPTISTAR LF MRI Ref. 200301 – Kit 2×60 ml with Y-Tube 250 cm
  • High-pressure syringe 130 ml for Magnetic Resonance Imaging compatible MEDTRON INYECTRON 82 MRT – Ref. 400301A (Kit with short spike and rapid fill tube) for MRI and CT
  • 200 ml Contrast Medium Syringe for MRI Ref. 400301B – Medtron Injektron 82 MRT Kit with Long Spout and 250 cm Y-Tube

Other related families

Products in this guide

Capacidad
  • 130 ml 2
  • 200 ml 5

View the Contrast Media Syringes family

Buying and selection tips

  1. Match the volume to the injector, not the other way round

    Some single-syringe kits are supplied in 130 ml and 200 ml, and two-barrel ones in splits of 60/60, 65/65, 65/115 and 100/100 ml. The usable volume is set by the injector's configuration, so it is advisable to start from the capacity the equipment accepts and then choose the split between barrels. A two-syringe kit does not replace a 200 ml one if the injector is configured for a single barrel.

  2. Short nozzle, long nozzle or both

    The nozzle is the part that connects the syringe to the injector and is not interchangeable between devices. There are kits supplied with a short nozzle, others with a long nozzle and others with both variants. If the order is recurring for the same room, fixing the variant avoids returns and failed set-ups.

  3. 250 cm Y connecting tube

    The MRI kits described include a coiled low-pressure Y connecting tube of 250 cm, with a connector. Check that the length and the connector fit the line already used in the room.

  4. Rapid-fill tube

    The 130 ml and 200 ml kits described include a rapid-fill tube. In the two-barrel kits the equivalent element is the low-pressure Y tube. Check which parts each reference includes.

  5. Presentation: box of 50 kits or single unit

    Some kits are supplied in boxes of 50 units and some references are offered singly. The sealed box makes sense when the room uses the kit continuously and always with the same injector; the single unit suits equipment with several modalities or occasional replacements.

Compatibility

250 cm low-pressure Y connecting tube with connector
It is the joining element between the kit and the patient line in the MRI kits described, which include it coiled. Check the connector before fixing the reference.
Short nozzle and long nozzle
The kit may include a single variant or both, and the nozzle must match the injector's receptacle. They are not interchangeable parts between models.

Frequently asked questions

How do I choose the pressure syringe kit that corresponds to my injector?

Start from the installed injector model and the volume it accepts. The kits are grouped by capacity and each is associated with specific equipment. Check the reference against the injector's compatibility list before finalising the order.

What is the difference between a 2×60 ml kit and a 65 + 115 ml one?

The split of volume between the two syringes, not the number of barrels. Some MRI kits are supplied with a short nozzle, a long nozzle and a 250 cm low-pressure Y connecting tube. The choice depends on the equipment and the room's protocol.

What length of connecting tube should I order for the kit?

The MRI kits described include a coiled low-pressure Y tube of 250 cm with a connector. If the room works with a different length, you need to check that the chosen kit keeps it.

How many kits are in a box and when is the single unit preferable?

Some references are supplied in boxes of 50 units and others singly. For a room with a single injector and stable consumption, the sealed box simplifies storage; with several devices, the single unit avoids tying up references that are not used.

Common questions

Confusing the kit volume with that of each syringe

In two-barrel kits the specification is expressed as 60/60, 65/65, 65/115 or 100/100 ml, that is, the volume of each syringe and not a total. Ordering a kit by a summed figure does not identify any reference.

Assuming that any pressure syringe works with any injector

No: a syringe is not equivalent if the model is not on the equipment's compatibility list, because the internal diameter, the length and the plunger retainer affect the fit. The check is made against the specific equipment, not against the product family.

Taking the short nozzle and the long nozzle as equivalent variants

They are different parts and the kit is supplied with one, the other or both. The nozzle must match the injector's receptacle.

Ordering only the syringe when the complete kit is needed

A kit may include nozzles and tubes that are not in the loose syringe. Check the contents of the reference so as not to be left without a part.