Description
Infusion set with inline final filter for high-risk therapy
The Intrapur® Inline infusion set from B.Braun (Ref. 4099842N) is a ready-to-use device, manufactured without PVC, DEHP or latex, incorporating an inline antibacterial filter of 0.2 µm for the gravity administration of high-risk solutions and drugs, with special indication for chemotherapy. Its design ensures patient protection against the microbial and particulate load present in the medication, maintaining a constant and reliable flow throughout the infusion. Professional presentation in a box of 20 units.
How does it work and what is it used for?
The device is based on an Intrafix® Primeline type infusion set fitted with an integrated inline filter with 0.2 µm membrane without electrostatic charge. This membrane provides mechanical retention of bacteria, fungi and particles, also offering a low protein binding capacity: a critical aspect in the infusion of biological and cytostatic drugs, as it minimises the loss of active ingredient during passage through the filter. It incorporates position-independent air separation (removes trapped air without the need to orient the line) and a drip chamber with a 15 µm filter that protects against coarse particles from the container. The set connects to the solution container via a standard spike and to the vascular access via a Luer-Lock connector, with a 150 cm tube. It is a device for gravity infusion: it is not indicated for use with infusion pumps.
Technical specifications
| Reference | 4099842N |
| Brand / Line | B.Braun · Intrapur® Inline (PVC-free) |
| Product type | Gravity infusion set with inline final filter |
| Filter | 0.2 µm · uncharged membrane · retention of bacteria and particles · low protein binding |
| Filter surface area | 14 cm² |
| Air separation | Position-independent |
| Tube length | 150 cm |
| Tube diameter | 3.0 mm internal / 4.1 mm external |
| Priming volume | ≈ 22.9 ml |
| Proximal connection | Standard spike for container |
| Distal connection | Luer-Lock connector |
| Materials | Free from PVC, DEHP and latex |
| Recommended usage time | 24 hours |
| Application | Chemotherapy and high-risk medication |
| Mode of use | Gravity infusion (not suitable for infusion pumps) |
| Presentation | Box of 20 units |
Equivalences and cross-references
Within the B.Braun family itself, the Intrapur® Plus filter exists (Refs. 4099800 and 4183916 in its PVC-free version), conceived as a filter with tubing to be coupled to a conventional set: it features a positively charged membrane (also retaining endotoxins) and allows up to 96 hours of use, but it is not a complete set with drip chamber and spike, so it is not interchangeable 1:1 with Ref. 4099842N. As a reference from another manufacturer, verified in an official source (Cytiva data sheet and GUDID database), the following comparable alternative by category is identified:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Pall / Cytiva | Posidyne® ELD (inline 0.2 µm filter with microbore tubing and Luer-Lock connections) | ELD96LL | Comparable by category (not interchangeable 1:1) | Positively charged nylon membrane (96 h, endotoxin retention); 24 cm microbore tubing; does not include drip chamber or spike for container connection; verified in GUDID (00636207000323) and Cytiva technical data sheet. |
There is no equivalence table validated by the manufacturer that officially cross-references Ref. 4099842N with other brands; consult the technical department before use in tenders.
Selection tips and variants of interest
- Gravity infusion: this set is designed exclusively for gravity infusion; if the protocol requires an infusion pump, select a specific pump-compatible device from the Intrafix range.
- Neonatal and paediatric therapy: consider inline filters dedicated to the paediatric population (e.g., the Posidyne NEO family from Cytiva), confirming the coding and specifications with the manufacturer before substitution.
- Need for endotoxin retention or prolonged use: if the treatment requires more than 24 hours or an electrostatically charged membrane, consult the Intrapur® Plus variant (Refs. 4099800 / 4183916).
- Drug-membrane compatibility: before administration, verify the compatibility of the drug (especially cytostatic and biological agents) with the 0.2 µm membrane and respect the maximum usage time of 24 hours.
- Product verification: check the CE marking, expiry date and integrity of the sterile packaging before each use.





Reviews